GEメーカーCalibur CBR-PB3-WDの使用説明書/サービス説明書
ページ先へ移動 of 37
Kalatel CBR - PB3 - WD ProBridge Receipt Printer Interface Product Overview & Installation Manual.
Kalatel CBR - PB3 - WD 2 0150 - 0261A Warning! To prevent fire and electronic shock, do not expose this product to rain or moisture. The lightning flash with the arrowhead symbol , within an equilater.
Kalatel CBR - PB3 - WD 3 0150 - 0261A Table of Contents 1 CBR - PB3 - WD ProBridge .................................................. 5 1.1 Kalatel CBR - PB3 - WD Description ...................................................... 5 1.2 Additional Equipment Provided by the Installer .
Kalatel CBR - PB3 - WD 4 0150 - 0261A 12 Cable Specifications .................................................... 33 13 Specific ations .............................................................. 35 14 Warranty and Service ........................
Kalatel CBR - PB3 - WD 5 0150 - 0261A 1 CBR - PB3 - WD ProBridge 1.1 Kalatel CBR - PB3 - WD Description The Ka latel CBR - PB3 - WD is a specific ProBridge unit for interfacing the DVMRe family of digital video multiplex/recorders Wayne Plus Receipt Printers (WP/RJ).
Kalatel CBR - PB3 - WD 6 0150 - 0261A 2 Before You Begin 2.1 Installation Summary The basic steps to install the CBR - PB3 - WD unit are: 1. Connect the PB3 to the Receipt Printer using the supplied cable. (If more than two PB3 units are used, verify that proper termination is set on each individual PB3 unit.
Kalatel CBR - PB3 - WD 7 0150 - 0261A 2.4 Installation Environment Power: Ensure that the installation si te’s AC power is stable and within the rated voltage of the external power supply. If the site’s AC power is likely to have spikes or dips, use power line conditioning or an Uninterruptible Power Supply.
Kalatel CBR - PB3 - WD 8 0150 - 0261A 4310 - 0008 220VAC Power Supply Power Supply Input Voltage: 220 Volt AC Tole rance: ±10% Frequency: 50 Hz Power Supply Output Voltage: 12 Volt DC Current: 110mA Power: 1.
Kalatel CBR - PB3 - WD 9 0150 - 0261A 3 ProBridge Diagram SW1 Dipswitch 1-8 Port 2 Connects to ECR and Receipt Printer Power Supply Connector 12VDC Port 1 RS232 Connection to Triplex/DVMRe or PC Port .
Kalatel CBR - PB3 - WD 10 0150 - 0261A Default (Factory) Dipswitch Settin gs SW1 SW2 SW3 SW4 1 Up 1 Down 1 Down 1 Up 2 Up 2 Down 2 Down 2 Up 3 Up 3 Down 3 Down 3 Down 4 Down 4 Down 4 Down 4 Up 5 Up 5 .
Kalatel CBR - PB3 - WD 11 0150 - 0261A 4 Connection Diagram Receipt Printer Receipt Printer DVMRe Triplex RS232 Port 2 4310-0034B Cable 4 310 - 0034 B C a b l e RJ45 (Port 1) RJ45 (Port 0) RJ45 (Port .
Kalatel CBR - PB3 - WD 12 0150 - 0261A Termination Switch Termination is set on SW4 for PORT 0 ( Dipswitch #3 ) Termination is important whenever multiple PB3 units are interconnected via the unit’s built - in RS - 485 network. The default termination setting on the ProBridge 3 unit is with termination set to ON .
Kalatel CBR - PB3 - WD 13 0150 - 0261A 5 Detailed Installation Steps 5.1 PB3 Physical Installation 1. Disconnect the existing Receipt Printer cable from the back of the POS system and install the ECR Interconnect Cable (4310 - 0078A) to the Receipt Printer as shown on page 11.
Kalatel CBR - PB3 - WD 14 0150 - 0261A 5.2 Configuring the PB3 for POS Interface 1. Associating ECR data to a specific camera. Dipswitches 5 - 8 on SW1 are used for assigning an ECR ’ s transaction text to a specific camera. Please refer to Section 8 for the specific dipswitch came ra assignments.
Kalatel CBR - PB3 - WD 15 0150 - 0261A iii. If the unit fails to display transaction text, please go to the troubleshooting section of this manual. b. To verify proper operation using a DVM Re – CS/CD/eZ, please refer to Section 11 .
Kalatel CBR - PB3 - WD 16 0150 - 0261A NOTE 6 Special Functions If these settings are used, they must be turned off before normal transaction processing will resume. 6.1 Display Memory This setting displays all internal memory settings through Port 1 on the te xt box window of the selected camera on a DVMRe Triplex.
Kalatel CBR - PB3 - WD 17 0150 - 0261A As a troubleshooting tool, this element allows you to verify that the PB3 is able to send messages and have the DVMRe correctly capture data coming from the PB3.
Kalatel CBR - PB3 - WD 18 0150 - 0261A To exit this mode return the dipswitches to the following position: SW1 1 Up 2 Up 3 Up 4 Up Power must be cycled OFF and then ON to the ProBridge unit before the reset command will take effect.
Kalatel CBR - PB3 - WD 19 0150 - 0261A 7 Troubleshooting If you are unable to verify capture of transaction text, do the following: 1. Check that each device is properly powered. 2. Check that the ECR to Camera address is correctly programmed SW1 . 3.
Kalatel CBR - PB3 - WD 20 0150 - 0261A 7. Section 4 contains all of the default Jumper Settings , if it is necessary for you to manually configure the interface. Troubleshooting Guide Problem Solution Check to make sure the power transformer is plugged in properly.
Kalatel CBR - PB3 - WD 21 0150 - 0261A 8 Text to Camera Address This section contains dipswitch settings for associating a specific Cash Register’s transaction text with a specific camera on the DVMRe unit.
Kalatel CBR - PB3 - WD 22 0150 - 0261A SW1 Dipswitch 5 - 8 Camera Assignment Dipswitch Numbers Camera # 5 6 7 8 12 DOWN UP DOWN DOWN 13 DOWN DOWN UP UP 14 DOWN DOWN UP DOWN 15 DOWN DOWN DOWN UP 16 DOW.
Kalatel CBR - PB3 - WD 23 0150 - 0261A 9 Manual Switch Config Manual configuration should only be used if the “POS Device Selection” does not conform to your specific device because baud rates or protocols are slightly differe nt than the default values for the selected device.
Kalatel CBR - PB3 - WD 24 0150 - 0261A 9.1.2 Protocol Legend: Up (Off) = U Down (On) = D SW2 Switch Setting 5 6 7 8 q Protocol: Asynchronous q Parity: Even q Code: 8 - Bit ASCII q Mode: 1 Stop Bit U D.
Kalatel CBR - PB3 - WD 25 0150 - 0261A SW2 Swi tch Setting 5 6 7 8 q Protocol: Asynchronous q Parity: Even q Code: 8 - Bit ASCII q Mode: 2 Stop Bit D U D D q Protocol: Asynchronous q Parity: Odd q Cod.
Kalatel CBR - PB3 - WD 26 0150 - 0261A 10 HyperTerminal Setup Manual configuration can also be completed using Windows HyperTerminal in lieu of the dipswitches.
Kalatel CBR - PB3 - WD 27 0150 - 0261A 10.2 Setting up the ProBridge for HyperTerminal Operation 1. Start HyperTerminal and open a new Connection (FILE>NEW): Give the connection a name and select an Icon. Click OK. 2. Under “Connect Using” option select “COM1”.
Kalatel CBR - PB3 - WD 28 0150 - 0261A 10.3 Manual HyperTerminal Configuration q The configurable settin gs are: o Protocol o Baud Rate o Parity o # of Stop Bits o Charcter Set o POS Device Type 1. The following screen (or similar) will confirm that you are in HyperTerminal programming mode.
Kalatel CBR - PB3 - WD 29 0150 - 0261A NOTE 3. Setup Option 2 (Port #2) Port #2 is an RS - 232 port that connects the PB3 unit to the Rece ipt Printer Interconnect Cable. The settings will vary based upon the type of Receipt Printer in use. Once you have selected this option, there will be multiple selections available for each element.
Kalatel CBR - PB3 - WD 30 0150 - 0261A NOTE b. Menu Select ion 3 – Baud Rate Baud Rate is only used if Protocol option selected is Asynchronous. q 1200 q 2400 q 4800 q 9600 q 14.4K q 19.2K q 38.4K c. Menu Selection 4 – Parity q None q Odd q Even d.
Kalatel CBR - PB3 - WD 31 0150 - 0261A NOTE 11 PB3 - POS with DVMRe - CD/CS Units If the u nit to be connected to the PB3 is a DVMRe - CD (Duplex) or a DVMRe - CS (Simplex) unit, please note the following changes to the normal installation and configuration process below.
Kalatel CBR - PB3 - WD 32 0150 - 0261A gender changer is added to match the DB9M connector needed for the port on the DVMRe - CD/CS. ii. Modem must be configured for Port 1.
Kalatel CBR - PB3 - WD 33 0150 - 0261A 12 Cable Specifications ProBridge to Triplex (DVMRe - CT) Part Number : 4310 - 0034B Communication Type: RS232 Connector Type: RJ - 45, RJ - 45 Cable Required: 5 Fo ot RJ - 45 to RJ - 45 Triplex RS232 Cable (Supplied).
Kalatel CBR - PB3 - WD 34 0150 - 0261A ProBridge to ProBridge Cable Part Number : Installer Provided Communication Type: RS - 485 Connector Type: RJ45, RJ45 Cable Required: RS - 485 Interconnect Cable (up to 3,000’)). Interconnects multiple PB3’s in a RS485 network.
Kalatel CBR - PB3 - WD 35 0150 - 0261A 13 Sp ecifications Physical Housing Metal enclosure. Dimensions (W x L x H) 4.0” x 7.0” x 1.0”. (100mm x 175mm x 25 mm) Nominal Weight 4.8 oz (136 g) Shipping Weight 1 lb (453 g) packaged, including the external AC power supply and manual.
Kalatel CBR - PB3 - WD 36 0150 - 0261A 14 Warranty and Service 14.1 Factor y Service If the unit requires factory service, contact the dealer who supplied the unit to you for the correct procedures on returning the unit to the factory or the nearest factory service center.
Kalatel CBR - PB3 - WD 37 0150 - 0261A For all non - warranty repairs , the customer will be billed f or parts, labor, and shipping. Labor will be billed in half - hour increments. Note: Customers requesting an estimate prior to repair will be notified by phone.
デバイスGE Calibur CBR-PB3-WDの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
GE Calibur CBR-PB3-WDをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGE Calibur CBR-PB3-WDの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。GE Calibur CBR-PB3-WDの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。GE Calibur CBR-PB3-WDで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
GE Calibur CBR-PB3-WDを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGE Calibur CBR-PB3-WDの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、GE Calibur CBR-PB3-WDに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGE Calibur CBR-PB3-WDデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。