R ange H oods GE Appliances V ented 164D3333P240 49-80025-1 06-01 JR 626901A Safety Information . . . . . . . . 3 Operating/Care and Cleaning Instr uctions Charcoal Filters . . . . . . . . . . . .5 Grease Filters . . . . . . . . . . . . . .4 Hood Lights .
2 Operating Instructions Safety Instructions Customer Service Installation Instructions Inside you will find many helpful hints on how to use and maintain your range hood properly . Just a little preventive care on your part can save you a great deal of time and money over the life of your range hood.
READ AND FOLLOW THIS SAFETY INFORMA TION CAREFULL Y . READ AND SA VE THESE INSTRUCTIONS SAFETY PRECAUTIONS 3 Installation Instructions Customer Service Safety Instructions Operating Instructions IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING.
4 Operating Instructions Safety Instructions Customer Service Installation Instructions Using the hood controls. Throughout this manual, features and appearance may vary from your model. FAN Control T urn or press (according to your model) the FAN speed control to LO , MED , HI or BOOST , as needed.
5 Installation Instructions Customer Service Safety Instructions Operating Instructions T o clean the hood surface, use a hot, damp cloth with a mild detergent suitable for painted sur faces. Use a clean, hot, damp cloth to remove soap. Dry with a dr y , clean cloth.
BEFORE YOU BEGIN 6 Installation Range Hood Instructions Models JV535 JV635 JV536 JV636 JV565 JV665 JV566 JV666 Read these instr uctions completely and carefully . • IMPORT ANT – Save these instructions for local inspector’ s use. • IMPORT ANT – Observe all governing codes and ordinances.
7 DUCTING CHAR T–JV5 Series Models DUCTING CHAR T–JV6 Series Models Equivalent Length in Feet 0 25 50 75 100 125 150 3 1 ⁄ 4 ″ x 10 ″ Rectangular T ransition to 6 ″ Round = 4.
DUCT EQUIV ALENT NUMBER PIECES LENGTH x USED = TOT AL 3 1 ⁄ 4 ″ x 10 ″ 1 Ft. x ( ) = Ft. Rect., straight 7 ″ Round, 1 Ft. x ( ) = Ft. straight 6 ″ Round, 1 Ft. x ( ) = Ft. straight 3 1 ⁄ 4 ″ x 10 ″ 8.5 Ft. x ( ) = Ft. Rect. 90° elbow 3 1 ⁄ 4 ″ x 10 ″ 7 Ft.
P ART QUANTITY Metal Grease Filters 2 Mounting Screws 4 Exhaust Adaptor 1 (for 3 1 ⁄ 4 ″ x 10 ″ rect. venting) Exhaust Adaptor Screws 2 Exhaust Adaptor 1 (for 7” round venting) 9 • If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.
10 Outside top exhaust (V ertical duct–3 1 ⁄ 4 ″ x 10 ″ Rectangular) Outside rear exhaust (Horizontal duct–3 1 ⁄ 4 ″ x 10 ″ Rectangular) Outside top exhaust (V ertical duct–7 ″ Round) A C B CHOOSE VENT OPTION The outside vent exhaust option that your installation requires will determine the hood knockouts that you will use.
11 REMOVE EXHAUST ADAPTOR Remove the 7 ″ round exhaust adaptor from the top of the hood. Set it aside along with its mounting screws. 7 ″ round exhaust adaptor REMOVE FIL TERS Remove the shipping tape holding the metal grease filters in place. Pull down on the filter tabs and lift the filters out.
12 REMOVE DUCT KNOCKOUT(S) If recirculating , non-vented ductless (optional for JV5 Series models only), see note below and skip to Step 11 D and proceed . W e do not r ecommend the recirculated configuration for JV6 Series models. Using a flat blade screwdriver , remove the appropriate duct knockout(s) from the top or back of the hood.
13 MARK HOLES Select the vent option that your installation will require and proceed to that section: Hood mounting screws (4) 13 15 ⁄ 16 ″ (30 ″ hood) 16 15 ⁄ 16 ″ (36 ″ hood) 13 15 ⁄ 1.
TROUBLESHOOTING CHECKLIST If the hood seems to be operating at high speed when the control is not set on high, or if ventilation seems inadequate, check the following: ❏ Knockouts not removed from hood. ❏ Damper blade not opening. ❏ Reduced air flow because the duct is too small or the duct length is too long.
15 GE Range Hood W arranty . All warranty service provided by our Factory Service Centers or an authorized Customer Care ® technician. For service, call 800-GE-CARES. For The Period Of: GE Will Replace: One Y ear Any part of the range hood which fails due to a defect in materials or workmanship.
16 Operating Instructions Safety Instructions Customer Service Installation Instructions Service T elephone Numbers. GE Answer Center ® 800.626.2000 The GE Answer Center ® is open 24 hours a day , 7 days a week. OR Visit our W ebsite at: www .geappliances.
デバイスGE JV535の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
GE JV535をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGE JV535の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。GE JV535の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。GE JV535で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
GE JV535を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGE JV535の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、GE JV535に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGE JV535デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。