Us e and Care & Installation G uide Downdraft Vent System Models: JVB34 JVB65 JVB35 JVB93 JVB64 JVB96 GE Appliances Safety Instructions .........................2 Operating Instructions, Tips Canning ...............................................
W ARNING—TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJUR Y TO PERSONS, OBSER VE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer .
SER VICING NOTE: BE SURE ELECTRICAL POWER IS OFF BEFORE SER VICING THE UNIT . It may be necessary to remove the downdraft blower system from the cabinet in order to service components such as the blower motor or air vent mechanism. Disconnect power to the cooktop and remove it first.
Gr ease Filter The efficiency of your downdraft depends on a clean filter . Frequency of cleaning depends on the type of cooking you do. Grease filters should be cleaned at least once a month. Never operate the downdraft without the filters in place. T o r emove: Pull the filters out by grasping them and pulling straight up.
5 INST ALLA TION INSTRUCTIONS Before Starting Installation Check the Following Requirements This downdraft blower system is designed to be used to exhaust smoke and odors when cooking with all GE electric and sealed bur ner gas cooktops (not approved for standar d bur ner gas cooktops).
30 ″ COOKT OPS/DOWNDRAFT UNITS JVB34, JVB35, JVB93 Figure 2 Overall Cutout Dimensions Figure 3 Cutout for Vent Figure 1 Overall Cooktop Dimensions 1 2 3 NOTE: AGAINST -THE-W ALL INST ALLA TIONS ARE LIMITED DUE TO DIMENSION REQUIREMENTS. REFER TO DET AILS BELOW .
7 36 ″ COOKT OPS/DOWNDRAFT UNITS JVB64, JVB65, JVB96 Figure 2 Overall Cutout Dimensions Figure 3 Cutout for Vent Figure 1 Overall Cooktop Dimensions 1 2 3 NOTE: AGAINST -THE-W ALL INST ALLA TIONS ARE LIMITED DUE TO DIMENSION REQUIREMENTS. REFER TO DET AILS BELOW .
INST ALLA TION INSTRUCTIONS (continued) 8 Plan the Ductwork 1. This downdraft blower system is designed for use with 3 1 ⁄ 4 ″ x 10 ″ ductwork (can be transitioned to 6 ″ round). Three dif ferent discharge directions ar e available with side--to-side adjustment for accurate alignment of ductwork.
9 Plan the Wiring 1. The downdraft blower system draws 4 AMPS and requires a 120 V AC, 60 Hz cir cuit. 2. The unit has a 2 ft. long power cord with a 3-pronged plug. Plan to provide a gr ounded outlet in a location which will allow the unit’s power cord to r each.
10 INST ALLA TION INSTRUCTIONS (continued) Install the Downdraft 1. Set the downdraft into the opening. Extend the leveling brackets to the floor of the cabinet so the downdraft sits straight. ( NOTE: Leveling brackets can be removed and r e-attached in other positions.
1 1 Adjust the Switch The downdraft is factor y-adjusted for pr oper operation. However , shipping and handling may af fect the positions of the activating switch. T o adjust position of activating switch: 1. If the downdraft is plugged into the electrical outlet, unplug it.
WHA T IS COVERED FULL ONE-YEAR W ARRANTY For one year from date of original purchase, we will provide, free of charge, parts and service labor in your home to repair or replace any part of the downdraft system that fails because of a manufacturing defect.
デバイスGE JVB35の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
GE JVB35をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGE JVB35の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。GE JVB35の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。GE JVB35で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
GE JVB35を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGE JVB35の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、GE JVB35に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGE JVB35デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。