AmanaメーカーHRV-300Dの使用説明書/サービス説明書
ページ先へ移動 of 28
1 Heat Recovery V entilators INST ALLA TION, OPERA TION AND MAINTENANCE MANUAL HRV -150 • HRV -150D HRV -200 • HRV -200D • HRV -300D Y our ventilation system should be installed in conformance w.
2 T ABLE OF CONTENTS TECHNICAL DA T A HRV(D) Series .................................................................................................. 3 HRV Series .......................................................................................
3 HRV Series HRV 150D & HRV 200D Introducing the NEW Heat Recovery V entilators (HRV). As with previous designs, incoming fresh outdoor air is filtered before it is heated by the stale outgoing air through a aluminum heat recovery core.
4 Dimensions A B CD E 5 TH port for recirculation defrost type models only 0 0.2 0.4 0.6 0.8 1 1.2 0 50 100 150 200 250 300 40 08 0 SHR(D) 1505R SHR(D) 1505R SHR(D) 2005R 120 160 Airflow (cfm) Airflow.
5 Introducing the NEW Heat Recovery V entilators (HRV). As with previous designs, incoming fresh outdoor air is filtered before it is heated by the stale outgoing air through a aluminum heat recovery core.
6 Dimensions A B C D E 0 0.2 0.4 0.6 0.8 1 1.2 0 50 100 150 200 250 300 40 08 0 SHR 1504 SHR 1504 SHR 2004 120 160 Airflow (cfm) Airflow (L/s) Static Pressure (in WC) Static Pressure (Pa) 200 240 19 0.
7 Introducing the NEW Heat Recovery V entilators (HRV). As with previous designs, incoming fresh outdoor air is filtered before it is heated by the stale outgoing air . The HRV then distributes the preheated fresh filtered air throughout the home by direct ductwork installed specifically for the HRV or thr ough the ductwork of a forced-air system.
8 Dimensions 22.20" 5 64mm 17.36" 4 41mm 2.20" 56mm 2.20" 56mm 50.87" 1292mm 5 TH port for recirculation defrost type models only 0 0.2 0.4 0.6 0.8 1 1.2 0.00 50.00 100.00 150.00 200.00 250.00 300.00 40.00 0.00 80.00 S HR3005R 120.
9 OPERA TION Winter: Humidity control is very important during the winter months. This is when problems will be most apparent since condensation on the windows will often occur . The colder the outside temperature, the greater the risk of condensation in the home.
10 15-min T imer - RT -15M - The 15-minute remote timer is typically installed in areas where contaminated such as moisture and odors, are produced. Simply push the button and the HRV will activate to high speed for 15 minutes.
11 OPERA TION (CONT'D) OPTIONAL DIGIT AL CONTROL Note: All controls are low voltage. 18 to 24 gauge wire is recommended. FIL TER LIGHT RESET & MODE FAN SPEED SELECTOR Pr ess to reset the filter mainte- nance reminder light.
12 • Install the unit close to the outside wall on which the supply and exhaust hoods will be mounted. • Have a nearby power supply 120 V olts, 60Hz. • Have the possibility of mounting the unit to suppor ting beams. • Mount the unit as level as possible in or der to allow pr oper condensate drainage.
13 3 Push the hood into the opening. Attach the hood to the outside wall with mounting screws. Repeat the installation procedure for both the Supply and Exhaust hood. 2 Pull the insulated flexible duct through the opening until it is well extended and straight.
14 PRACTICAL TIPS INST ALLING DUCTS TO / FROM INSIDE • Building Codes and Combustion Appliance Installation Codes do not allow location of return air grilles or any opening such as a “breathing tee” in an enclosed room with spillage susceptible combustion appliances.
15 • For new construction, the rigid ducts are run in the walls. • Choose the location for your Supply and Exhaust grilles. The Supply grilles should be located in every habitable room and the Exhaust Grilles should be located in the wet rooms.
16 Bedrooms Fresh Air Exhaust Air Central Control - optional Fresh air to living room Exhaust Bathroom 460 mm 1800 mm HRV Ducting Fifth Port Units All HRV(D)’ s have a fifth duct port on top of the unit. This duct port is for both defrost and the recirculation mode.
17 Bedrooms Fr esh Air Exhaust Air Furnace thermostat Exhaust Bathroom 460 mm HRV Central Control - optional Return Air HRV Connection 1800 mm INST ALLA TION EXAMPLES (CONT'D) Example diagram onl.
18 INST ALLA TION EXAMPLES (CONT'D) DIRECT CONNECTION of both the HRV SUPPL Y AIR STREAM and EXHAUST AIR STREAM to the FURNACE COLD AIR RETURN Simplified Installation Option 1 (Return/Return Meth.
19 INST ALLA TION EXAMPLES (CONT'D) DIRECT CONNECTION of both the HRV SUPPL Y AIR STREAM & EXHAUST AIR STREAM to the FURNACE COLD AIR RETURN & SUPPL Y AIR SIDE Simplified Installation Opt.
20 AIR FLOW BALANCING CAUTION • If the unit’ s airflows are not properly balanced... - The unit may not operate at it’ s maximum efficiency. - Heat recovery core damage may occur . - The unit’ s use could cause negative or positive pressure in your home causing cold air to enter or other combustible equipment to backdraft.
21 AIR FLOW BALANCING (CONT'D) 1 For this flow measuring station, cut the duct and place the flow measuring station between each station. Make sure that the flow measuring station’ s air direction arrow points in the direction of the airflow. Secure the flow measuring station with duct tape.
22 MAINTENANCE The filters (2) need to be checked and cleaned every three months or when they appear dirty . Wash in warm sudsy water (mild detergent) or use a soft brush vacuum. The filters should be replaced when they can no longer be cleaned properly .
23 TROUBLESHOOTING Solutions Causes Problem Dehumidistat control is set too low Dehumidistat control is set too high Sudden change in temperature Storing too much wood for heating Dryer vent exhaust i.
24 ELECTRICAL CONNECTIONS Low V oltage Control Wiring Connections * Please see instruction on individual controls for proper wiring and set up of control selected.
25 ELECTRICAL CONNECTIONS (CONT'D) - + C ustom defrost m ode jumper selection 3 position mode selection switch Accessor y Control Contact (Open & Closes contact when HR V/ERV is ON/OFF) Diagn.
26.
27.
The product is manufactured by Fantech, Inc. Fantech reserves the right to modify , at any time and without notice, any or all of this product's features, designs, components and specifications. Item #: 402950 Rev . 1 Rev Date: 11022006 United States 1712 Northgate Blvd.
デバイスAmana HRV-300Dの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Amana HRV-300Dをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmana HRV-300Dの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Amana HRV-300Dの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Amana HRV-300Dで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Amana HRV-300Dを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmana HRV-300Dの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Amana HRV-300Dに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmana HRV-300Dデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。