PO WER SY STEMS, INC. ® Owner’ s Manual GTS “W” T ype A utomatic T ransfer Switc h 200 Amp, 250 V olts Model Nos. 004635-1 004635-2 This manual should remain with the unit.
Generac ® Pow er Systems, Inc. Generac cannot possibly anticipate every possible circumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit are, therefore, not all-inclusive.
T able of Cont ents Generac ® Pow er Systems, Inc. 1 Safety Rules..........................................Inside Front Cover Section 1 — General Information ..................................2 1.1 Introduction .....................................
2 Generac ® Pow er Systems, Inc. Section 1 — General Information Generac GT S “W” T ype T ransfer Switch 1.1 I NTRODUCTION This manual has been prepared especially for the purpose of familiarizing personnel with the design, application, installation, operation and servicing of the applicable equipment.
Generac ® Pow er Systems, Inc. 3 2.1 I NTRODUCTION T O I NST ALLA TION This equipment has been wired and tested at the fac- tory . Installing the switch includes the following pro- cedures: • Mounting the enclosure. • Connecting utility and generator power source leads.
4 Generac ® Pow er Systems, Inc. Solderless, screw-type terminal lugs are standard. The conductor size range is as follows: Conductor sizes must be adequate to handle the max- imum current to which they will be subjected; based on the 75°C column of tables, charts, etc.
Generac ® Pow er Systems, Inc. 5 3.1 F U NCTIONAL TE S T S AN D ADJ US TM ENT S Following transfer switch installation and intercon- nection, inspect the entire installation car efully . A competent, qualified electrician should inspect it. The installation should comply strictly with all appli- cable codes, standards, and r egulations.
6 Generac ® Pow er Systems, Inc. 3. When certain that UTILITY supply voltage is cor- rect and compatible with transfer switch ratings, turn OFF the UTILITY supply to the transfer switch. 4. On the generator panel, set the A UTO - OFF - MANU AL switch to MANU AL position.
Generac ® Pow er Systems, Inc. 7 Failure to do so may r esult in damage to cer- tain rotary equipment. 8. Set the generator’s main circuit breaker (CB1) to its OFF or OPEN position. 9. Set the Auto/Off/Manual switch to the OFF posi- tion to shut down the generator .
8 Generac ® Pow er Systems, Inc. Section 4 — Mounting Dimensions Generac GT S “W” T ype T ransfer Switch Mounting Dimensions – Drawing No. 0D3 7 1 4-B 180 514 612 490 430 V alues are in Millimeters Note: Diameter of Mounting holes (A) is 6.
Generac ® Pow er Systems, Inc. 9 - OPEN SWITCH TO TEST - 2 A @ 2 50 Vac MIN. S WITCH TYPE , SPST E LECTRICAL RATINGS , NO TE : I F THERE ARE NO MATCHING TERMINAL CONNECTIONS FOR LOAD 1 ( T1 ) AND L OAD 2 ( T2 ) IN THE GENERATOR CONTROL PANEL DO NOT CONNECT THESE W IRES , FAILURE OF THE CONTROL BOARD WILL OCCUR IF CONNECTED.
B2 A2 B1 A1 C 6 9 TR 1 7 TR E1 E1 N2A N2A N1A E2 2 05 12 6 TR 2 3 1 94 2 3 1 94 N2A LE G EN D G T S N O TE S: A LL CO NTA C T S S H O WN WIT H TRAN S FER S WIT C H IN U TILIT Y P OS ITI O N .
Generac ® Pow er Systems, Inc. 11 TR G T S T1 E1 N1 T2 E2 N2 B1 B2 A2 A1 N1A N1A 12 6 E2 E1 N2A 2 05 N1A 2 05 E1 E1 A 7 1 B 9 3 T1 T2 N1A N2A 12 6 2 05 N1A N1A N1A N1A F2 F1 23 19 4 T S U TILITY 2 U .
B2 A2 B1 A1 C 6 9 TR 1 7 TR E1 E1 N2A N2A N1B E 2 2 05 12 6 TR 2 3 1 94 2 3 1 94 N2A LE G EN D G T S N O TE S: 1. ) ALL CONTACTS SHOWN WIT H TRAN S FER S WIT C H IN U TILIT Y P OS ITI O N .
Generac ® Pow er Systems, Inc. 13 TR G T S T1 E1 N1 T2 E2 N2 B 1 B2 A2 A1 N1B N1B 12 6 E2 E1 N2A 2 05 N1B 2 05 E1 E1 A 7 1 B 9 3 6 T1 T 2 N1B N2A N 3 E 3 T 3 2 1 8 7 3 4 5 6 12 6 2 05 N2A N2A N2A N1B.
S WIT C H I S F O R US E WITH CO NTR O L M O D U LE A SS EMBLY # 079844 , #075595 , AND #083494 T RAN S FER S WIT CH W AUKESHA WI , 53187 G ENERA C P O WER S Y S TEM S 0 E4 3 1 3 3 4 23 14 LO AD 2 LO .
Generac ® Pow er Systems, Inc. 15 Section 6 — Exploded Views and P arts List Generac GT S “W” T ype T ransfer Switch 200 A, 2P ole Switch Assembly – Drawing No. 0E2868$-D ITEM P ART NO . QTY . DESCRIPTION 1 0C8884 1 XFER SW -W 200A600V2P 20 A 99 4 9 6 LUG SLDLSS 400-#4X1/4-20 CU7AL 3 0C48 9 6 6 SCREW FHM M8-1.
16 Generac ® Pow er Systems, Inc. A9949 - S A9949S 0 A 99 4 9 - S C 7 90 7D- S 0 D4 5 4 5 C7907DS 0C8885 -L S 0A9949 - S 0A9949S 7 39 40 RATED VOLTAGE 600 VA C CS A 480 VA C U L XXXXXX A1 CS3-8X16T C.
Generac ® Pow er Systems, Inc. 17 ITEM P ART NO . QTY . DESCRIPTION 1 0C8885 1 XFER SW -W 200A600V3P 20 A 99 4 99 LUG SLDLSS 400-#4X1/4-20 CU7AL 3 0C48 9 6 9 SCREW FHM M8-1.25 X 20MM CR 4 067 9 8 99 NUT LOCK FL M8-1.25 YEL CHR 5 026 9 02 7 SCREW HHTT #8-32 X 1/4 CZ 6 0C7 9 07D 2 CO VER LUG 3P 150/200AMP 7 045771 1 NUT HEX M8-1.
Part No. 0E4334 Revision C (05/05/05) Printed in U.S.A. Section 7 — W arranty Generac GT S “W” T ype T ransfer Switch GENERA C PO WER SYSTEMS ST AND ARD TWO-YEAR LIMITED W ARRANTY FOR GENERA C TRANSFER SWITCH SYSTEMS NO TE: ALL UNITS MUST HA VE A ST ART -UP INSPECTION PERFORMED BY AN A UTHORIZED GENERAC DEALER.
デバイスGenerac Power Systems 004635-1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Generac Power Systems 004635-1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGenerac Power Systems 004635-1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Generac Power Systems 004635-1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Generac Power Systems 004635-1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Generac Power Systems 004635-1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGenerac Power Systems 004635-1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Generac Power Systems 004635-1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGenerac Power Systems 004635-1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。