Automatic T ransfer Switch Owner’ s Manual A TS “HS” T ype Models: 004635-3 (200 Amp, 250 V olts) and 004678-2 (100 Amp, 250 V olts) This manual should remain with the unit.
Generac P ower Systems, Inc., hereafter referred to as the “manufacturer”, cannot anticipate every possible circumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit are, therefore, not all-inclusive.
T able of Contents 1 Safety Rules..........................................Inside Front Cover Section 1 — General Information ..................................2 1.1 Introduction ............................................................2 1.2 Equipment Description .
2 Section 1 — General Information A TS “HS” T ype T ransfer Switch 1.1 I NTRODUCTION This manual has been prepared especially for the purpose of familiarizing personnel with the design, application, installation, operation and servicing of the applicable equipment.
3 2.1 I NTRODUCTION T O INST ALL A TION This equipment has been wired and tested at the fac- tory . Installing the switch includes the following pro- cedures: • Mounting the enclosure. • Connecting power source and load leads. • Connecting the generator start circuit.
4 Section 3 — Operation A TS “HS” T ype T ransfer Switch Connect power source load conductors to clearly marked transfer mechanism terminal lugs as follows 1. Connect UTILITY (NORMAL) power source cables to switch terminals N1, N2. 2. Connect EMERGENCY (ST ANDBY) source power cables to transfer switch terminals E1, E2.
5 3.2.2 CL OSE T O EM ERGENCY SOURCE SI DE Before proceeding, verify the position of the switch by observing the position of the manual operation han- dle in Figure 3.1. If the handle is DOWN, the contacts are closed in the EMERGENCY (ST ANDBY) position.
6 PROCEED WITH CAUTION. GENERA TOR OUT- PUT VOL T AGE IS NOW BEING DELIVERED TO TRANSFER SWITCH TERMINALS. CONT ACT WITH LIVE TERMINALS RESUL TS IN EXTREMEL Y DANGEROUS AND POSSIBL Y FA T AL ELECTRI- CAL SHOCK. 7. W ith an accurate AC voltmeter and frequency meter , check the no -load, voltage and frequency .
7 Section 4 — Notes A TS “HS” T ype T ransfer Switch.
8 Section 4 — Notes A TS “HS” T ype T ransfer Switch.
9 Section 4 — Notes A TS “HS” T ype T ransfer Switch.
Section 5 — Installation Diagram A TS “HS” T ype T ransfer Switch Drawing No. 0E7 08 1 3 77mm [ 14.84" ] 5 08.5mm [ 20.02" ] KN OC K OU T SU ITABLE F OR 1 " , 1-1/2" AND 2" CONDUIT SIZE 3 PLA C E S 1 79.5mm [ 7.07" ] 4 20mm [ 16.
11 - OPEN SWITCH TO TEST - 2 A @ 2 50 Vac MIN. S WITCH TYPE , SPST E LECTRICAL RATINGS , NO TE : I F THERE ARE NO MATCHING TERMINAL CONNECTIONS FOR LOAD 1 ( T1 ) AND L OAD 2 ( T2 ) IN THE GENERATOR CONTROL PANEL DO NOT CONNECT THESE W IRES , FAILURE OF THE CONTROL BOARD WILL OCCUR IF CONNECTED.
12 Section 6 — Electrical Data A TS “HS” T ype T ransfer Switch Electrical Schematic - Drawing No. 0E6093-B.
13 Section 6 — Electrical Data A TS “HS” T ype T ransfer Switch Electrical Schematic - Drawing No. 0E6093-B.
14 6 9 8 16 3 7 21 7 3 23 15 24 4 36 2 194 25 28 N E U TRAL 29 17 18 13 14 11 13 40 26 19 10 20 22 3 2 3 1 35 5 30 39 33 3 4 12 1 3 2 4 30A,600V 30A, 600V 073591 - T 073591T 30A,600V 30A, 600V 073591 .
15 ITEM P ART NO . QTY . DESCRIPTION 1 0C2237 1 TR SW -HSB 100A 2P 250V 2 077033 6 LUG SLDLSS 1/0-#14X9/16 AL/CU 3 036932 6 SCREW PPHM #10-32 X 1/4 4 022152 6 W ASHER LOCK #10 5 074908 4 SCREW HHTT M5-0.
N E UT 30 8 6 9 20 19 7 15 22 3 1 13 21 16 11 10 PT/NO A2595 5 5 LO AD 2 LO AD 1 UTILITY 2 UTILITY 1 194 23 4 1 29 4 2 A C A A A 26 23 28 14 13 18 A 27 40 35 33 24 A 12 17 38 3 4 36 3 A 5 25 2 1 4 05 .
17 Section 7 — Exploded Views and P ar ts List A TS “HS” T ype T ransfer Switch 200A T ransfer Switch Assembly – Drawing No. 0E5 7 82$-J ITEM P ART NO . QTY . DESCRIPTION 1 0D9618 1 TR SW -HSB 200A 2P 250V 2 0E3375 6 LUG SLDLSS 250-#6 AL/CU 3 0F1252 6 SCREW BHSC 1/4-20 X 3/8 4 022097 6 W ASHER LOCK M6-1/4 5 066849 5 SCREW HHTT M5-0.
Part No. 0E6347 Revision H (02/09/05) Printed in U.S.A. Section 8 — W arranty A TS “HS” T ype T ransfer Switch GEN ER AC PO WER S Y STEMS, INC. W AR R ANT Y/SERVICE Generac P ower Systems, Inc.
デバイスGenerac Power Systems 004678-2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Generac Power Systems 004678-2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGenerac Power Systems 004678-2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Generac Power Systems 004678-2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Generac Power Systems 004678-2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Generac Power Systems 004678-2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGenerac Power Systems 004678-2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Generac Power Systems 004678-2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGenerac Power Systems 004678-2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。