Contents: Installation Instructions: page 2 Pump Specifications: pages 3-5 Parts List/Exploded View: pages 6-7 Kits/Torque Specs: page 8 Trouble Shooting: page 9 Repair Instructions: page 10-11 Dimens.
2 Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc.
3 Specifications Model GP5132 V olume ................................................................................................... Up to 29 GPM Discharge Pressure ................................................................................ Up to 3000 PSI Speed .
4 Specifications Model GP5136 V olume ................................................................................................... Up to 35 GPM Discharge Pressure ................................................................................ Up to 2200 PSI Speed .
5 V olume ................................................................................................... Up to 43.3 GPM Discharge Pressure ................................................................................ Up to 1500 PSI Speed .....
6 ITEM PART DESCRIPTION QTY. 1 13266 Crankcase 1 2 13000 Oil Filler Plug Assembly 1 3 07186 Oil Sight Glass Assy. 1 4 13267 Crankcase Cover 1 5 13268 O-Ring 1 8 07105 Oil Dip Stick 1 9 01009 O-Ring, D.
7 Exploded V iew - GP5100 Series.
8 GP5100 SERIES REPAIR KITS Plunger Packing Kits GP5132 #09290 Qty. Part # Description 3 08183 O-Ring 3 13360 Grooved Ring 6 13027 V -Sleeve GP5136 #09229 Qty. Part # Description 3 13289 O-Ring 3 08183 O-Ring 3 13291 Grooved Ring 6 07144 V -Sleeve GP5145 #09228 Qty.
9 PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace .
10 REPAIR INSTRUCTIONS Note: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump's non- metal parts (i.e., the elastomers) from cutting and scoring.
11 To Disassemble Gear End 1. Loosen Inner Hexagon Screws (49) for the V alve Casing (43) with an allen wrench. Carefully remove Valve Casing from the Crankcase (1). 2. Loosen Inner Hexagon Screws (10) for the Crankcase Cover (4) with an allen wrench and remove Crankcase Cove r .
10mm X 63mm Key DIMENSIONS GIANT INDUSTRIES, INC. , 900 N. Westwood Ave., P.O. Box 3187 Toledo, Ohio 43607, Phone (419) 531-4600, FAX (419) 531-6836, www.giantpumps.com Copyright 1996 Giant Industries, Inc. 18.9" 3.06" 9.69" 8.27" 10.
デバイスGiant GP5132の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant GP5132をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant GP5132の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant GP5132の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant GP5132で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant GP5132を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant GP5132の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant GP5132に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant GP5132デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。