Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Model GP7128 Contents: Installation Instructions: page 2 Pump Specifications: page 3 Exploded View: page 4 Parts List/Kit.
2 INSTALLATION INSTRUCTIONS Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc.
GP7128 HORSEPOWER REQUIREMENTS RPM GPM 3000 PSI 4000 PSI 5000 PSI 5800 PSI 300 7.2 15.4 20.6 25.7 29.8 400 9.5 20.4 27.1 33.9 39.4 550 13.1 28.1 37.4 46.8 54.3 600 14.3 30.6 40.9 51.1 59.2 650 15.5 33.2 44.3 55.4 64.2 700 16.7 35.8 47.7 59.6 69.2 750 17.
4 Exploded View - GP7128 Pump.
5 GP7128 PARTS LIST ITEM PART DESCRIPTION QTY. 1 07600 Crankcase 1 2 13000 Oil Filler Plug Assembly 1 4 07601 Crankcase Cover 1 5 07602 Seal for Cover 1 8 07603 Oil Dip Stick 1 9 01009 O-Ring, Dip Sti.
GP7128 Repair Instructions NOTE: Always take time to lubricate all metal and non-metal parts with a light film of oil before reassembling. This step will help ensure proper fit, at the same time protecting the pump non-metal parts (elastomers) from cutting and scoring.
7 11. Take a thin screw driver and pry out the grooved ring (39A). Note: This seal (39A) will not be reusable, so replace with a new part. For the seal-pack (41-43A), remove with either a socket wrench or use a screw driver to push against the rear lip of the pressure ring (41) or v-sleeves (42).
8 CAUTION: Don't loosen the 3 plunger (36) before the valve casing has been removed otherwise the plunger (36) could hit against the spacer pipe (51F) when the pump is being turned. Seal life can be increased if the pretensioning allows for a little leakage.
9 PUMP SYSTEM MA LFUNCTIONS M A LFUNCTIO N CA USE REMEDY The Pr essure and/ or the Delivery Drops W orn packing seals Replace packing seals Broken valve springs Replace springs Belt slippage Tighten o.
10 Preventative Maintenance Check-List & Recommended Spare Parts List Check Daily W eekly 50hrs Every Every Every 500 hrs 1500 hrs 3000 hrs Oil Level/Quality X Oil Leaks X W ater Leaks X Belts, Pu.
11 GP7128 Dimensions - Inches (mm).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never fail, period.
デバイスGiant GP7128の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant GP7128をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant GP7128の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant GP7128の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant GP7128で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant GP7128を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant GP7128の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant GP7128に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant GP7128デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。