GiantメーカーGP7136の使用説明書/サービス説明書
ページ先へ移動 of 12
Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Model GP7132 & GP7136 Contents: Installation Instructions: page 2 Pump Specifications GP7132: page 3 Exploded View: p.
2 INST ALLA TION INSTRUCTIONS Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc.
3 26.2 23.0 19.7 16.4 13.1 9.8 6.6 3.3 0 500 600 700 800 RPM NPSHR(FT -HEAD) Viscosity = 1 Centipoise 0 1500 3000 4500 PSI 95 90 85 80 75 70 LP [dB(A)] n-500 (1/min) n-300 (1/min) n-750 (1/min) GP7 1 32 HORSEPO W ER REQUIRMENTS R PM GPM 1000 PSI 1400 PSI 2000 PSI 2500 PSI 3000 PS I 4350 PS I 300 9.
4 Exploded View - GP7132 and GP7136 Pump s.
5 GP7132 and GP7136 PARTS LIST ITEM PART DESCRIPTION QTY. 1 07600 Crankcase 1 2 13000 Oil Filler Plug Assembly 1 4 07601 Crankcase Cover 1 5 07602 Seal for Cover 1 8 07603 Oil Dip Stick 1 9 01009 O-Ri.
6 26.2 23.0 19.7 16.4 13.1 9.8 6.6 3.3 0 200 400 600 800 RPM NPSHR(FT -HEAD) Viscosity = 1 Centipoise GP71 36 H O R SEPO WER REQUIREMENTS R PM G PM 1000 PS I 1400 PSI 2000 P S I 2500 PSI 362 5 PSI 300 11.3 8.1 11.3 16.1 20.2 29.3 400 15.0 10.7 15.0 21.
7 GP7132 AND GP7136 REP AIR INSTRUCTIONS NOTE: Always take time to lubricate all metal and non-metal parts with a light film of oil before reassembling. This step will help ensure proper fit, at the same time protecting the pump non-metal parts (elastomers) from cutting and scoring.
8 GP7132 AND GP7136 REP AIR INSTRUCTIONS 8. Separate plunger (36) from crosshead (25) by means of one open-end wrench. 9. Pull seal sleeves (39) out of their fittings in the crankcase. T ake seal case (38) out of seal sleeve (39). 10. If o-rings (38A) or support rings (38B) are damaged, replace with new parts.
9 GP7132 AND GP7136 REP AIR INSTRUCTIONS CAUTION: Don't loosen the 3 plunger (36) before the valve casing has been removed otherwise the plunger (36) could hit against the spacer pipe (51F) when the pump is being turned. Seal life can be increased if the pretensioning allows for a little leakage.
10 PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace.
11 GP7132 and GP7136 Dimensions (Inches).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never fail, period.
デバイスGiant GP7136の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant GP7136をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant GP7136の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant GP7136の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant GP7136で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant GP7136を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant GP7136の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant GP7136に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant GP7136デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。