Triplex Ceramic Plunger Pump Operation Manual Models GP714 5G B and GP7255AGB pump with gearbox Contents: Installation and Safety Instructions page 2 Pump Specifications (GP7145GB-2.4): page 3 Exploded View: page 4 Parts List: page 5 Pump Specifications (GP7255AGB-2.
2 INST ALLA TION INSTRUCTIONS NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600. Operation and Maintenance Check oil level prior to starting and ensure trouble-free water supply. Oil: Use only 2 gallons (7.5 liters) if ISO VG-220 synthetic gear oil.
Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. PULLEY INFORMATION Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts.
4 Exploded V iew - GP7145GB-2.4/GP7255AGB-2.4.
PARTS LIST - GP7145GB-2.4/GP7255AGB-2.4 5 ITEM PART DESCRIPTION QTY. 1 05324 Crankcase 1 1A 05313 Head for Oil Dipstick 1 1B 01009 O-Ring 1 2 13000 Oil Filler Plug Assy.
U.S. .................... ........... (Metric) V olume (Continuous) .............................................................. 65.8 GPM ..................... (250 LPM) V olume (Intermittent) ........................................................
Repair Kits - GP7145GB-2.4 and GP7255AGB-2.4 Plunger Packing Kit - GP7145GB-2.4 # 09603 Item Part # Description Qty . 38A 13156 O-Ring 3 38B 06258 O-Ring 3 39A 13290 Grooved Ring 3 42 13294 V -Sleeve 9 V alve Repair Kit # 09604 Item Part # Description Qty .
8 GP7145GB-2.4 and GP7255AGB-2.4 Repair Instructions TO CHECK VAL VES Loosen plugs (58), take out tension spring (57) and then remove the complete valve assembly (51) with either a valve tool or an M16 hexagon screw . T o remove the valve adapter (56) and tension spring (57), use a pullout tool size 5.
TO DISMANTLE REDUCTION GEAR Remove screws (G4). Using screwing two screws into the both thread bores, press off the gear cover (G2). Remove screw (G1 1) and take off the spacer ring (G7) and tension disc (G10). Push the cogwheel (G9) off the shaft by screwing two screws into both thread bores.
10 PUMP SYSTEM MA LFUNCTIONS M A LF UNCTION CA USE REM EDY The Pressure an d/ or th e Deliver y Drops W or n pack ing seals Replace pack ing seals Brok en valve spr ings Replac e spring s Belt slippag.
11 Dimensions - GP7145GB-2.4 and GP7255AGB-2.4 - Inches (mm).
10/07 GP7145GB_GP7255AGB.PMD GIANT INDUSTRIES, INC. 900 N. Westwood Ave. P.O. Box 3187 Toledo, Ohio 43607 (419) 531-4600 FAX (419) 531-6836 Copyright 2007 Giant Industries, Inc. www.giantpumps.com GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc.
デバイスGiant GP7255AGBの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant GP7255AGBをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant GP7255AGBの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant GP7255AGBの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant GP7255AGBで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant GP7255AGBを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant GP7255AGBの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant GP7255AGBに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant GP7255AGBデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。