GiantメーカーLP 122Aの使用説明書/サービス説明書
ページ先へ移動 of 12
Model s LP122A Series/LP123 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Updated 6/00 For Models LP122A LP122A-3100 LP122A-4000 LP123 Contents: Installation Instructi.
2 NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600 INST ALLA TION INSTRUCTIONS Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation.
3 L P1 22 A SER IES /LP1 23 PULLEY SELECTI O N AND H O RSEPOW ER R EQU IR EMEN TS GP M PU MP PU LLE Y MO T OR PULLEY R PM 6 00 PS I 800 PSI 1000 P SI 1300 PSI 200 0 PS I 22. 3 1 2.75" 3. 95" 500 9. 6 12. 7 15. 9 20.7 31.9 24. 7 1 2.75" 4.
4 Exploded View - LP122A Series/LP123 LP123 LP122A-3100 31 (LP122A and LP122A-4000) *LP122A-3100 Only! * *.
5 ITEM PART NO. DESCRIPTION QTY. 1 07759 Crankcase 1 2 13000 Oil Filler Plug 1 4 06085 Crankcase Cover 1 5 07104 O-Ring 1 6 07186 Oil Sight Glass W/Gasket 1 8 06086 Oil Dipstick 1 9 01009 O-Ring 1 1 0.
6 Plunger Packing Kit # 09135 (for pumps manufatured before 4/98) Qty . Part # Description 3 07740 O-ring 6 07741 V -Sleeve, W eep 6 07745 V -Sleeve 3 07653 O-Ring LP122A SERIES/LP123 PUMP REP AIR KITS V alve Assembly Kit LP122A. LP123, LP122A-4000 #09136 Qty .
7 PUMP SYSTEM MALFUNCTION MALFUNCTION The Pressure and/or the Delivery Drops Water in crankcase Noisy Operation Rough/Pulsating Operation with Pressure Drop Pressure Drop at Gun Excessive Leakage High.
8 LP122A Series/LP123 - Repair Instructions 1 . With a 30mm wrench, re- move the six (6) plugs (48) from the valve casing (43). Inspect the o-rings (48A) and replace if necessary. Remove the complete valve assembly (46A) by thread- ing a 12mm bolt into the spring retainer and pulling straight out.
9 1 1 . If previously disassembled thoroughly clean all exposed surfaces on the spacer (29E) and all exposed threads on the plunger bolt (29C) and the steel plunger base (25). Threads MUST be free of old loc-tite and any other material such as oil, grease, etc.
10 1 2 . Lubricate weep seal (36). Place, weep seal (36), and pressure ring (36A) into the seal sleeve (35). Assemble the o-ring (35A) onto seal sleeve and lubricate. 1 4 . Press seal sleeve assembly into the manifold and seat firmly. Put the support ring (41) on plunger with v-side facing the manifold.
11 LP122A/LP122A-3100/LP123 DIMENSIONS (mm) LP122A-4000 DIMENSIONS (mm).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never fail, period.
デバイスGiant LP 122Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant LP 122Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant LP 122Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant LP 122Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant LP 122Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant LP 122Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant LP 122Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant LP 122Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant LP 122Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。