Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Contents: Installation/Repair Instructions: pages 2-7 Exploded View: page 8 Parts List / Kits: page 9 Torque Specificatio.
2 NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600 INST ALLA TION INSTRUCTIONS Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation.
3 Hydraulic System Set Up 2.2 Pr essure Accumulator The purpose of the pressure accumulator , if installed, is to damp pulsation from the high-pressure pump and thus avoid vibrations in the discharge line. Gas in the pressure accumulator should be pretensioned to 50-60% of the maximum operating pressure.
4 4. Maintenance and Repair To Check Valves: Discharge Valves: Screw out hexagon screws (59) and remove valve casing (54). Pull seal case (46) out of valve casing (54.) Pull valve body (50 ) and seal case (46) apart. Using pliers, pull spring guide (55) out of the valve casing.
5 T o Check Seals and Plungers Unscrew hexagon screw (59) and take off valve casing (54.) Remove the screw-in joints (37B) and take off the elbow pipes (37A). Remove drip-return ring (44) from seal sleeve (36). Then pull seal sleeve (36) out of the crankcase.
6 Important! Check the leakage bores Æ 4 of the seal sleeves (36) and seal cases (46) for dirt and clean if necessary. The elbow screw-in joints (37B) and elbow pipes (37A) must also be checked for dirt and cleaned if necessary.
7 Remove connecting rod (conrod) screws, and push the front of the conrod parts forward as far as possible into the crosshead guide. Important! Conrods are marked for identification. Do not twist conrod halves. When reassembling, conrods are to be fitted back onto the shaft journals in their exact original position.
8 Model LP1000 - Exploded V ie w.
ITEM # PART # DESCRIPTION QTY 1 07759 Crankcase 1 2 13000 O i l F iller Plug Assy 1 4 06085 Crankcase Cover 1 5 07104 O-Ring for Cover 1 6 07186 O i l Sight Glass 1 8 06086 O i l D ipstick Assy 1 9 01.
10 Specifications Model LP1000 High-Pressure Plunger Pump V o lu me .................................................................................................. 3.4 GPM (12.8 LPM) Maximum Discharge Pressure ......................................
11 LP1000 DIMENSIONS (mm).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never fail, period.
デバイスGiant LP1000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant LP1000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant LP1000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant LP1000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant LP1000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant LP1000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant LP1000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant LP1000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant LP1000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。