GiantメーカーLP122A-4000の使用説明書/サービス説明書
ページ先へ移動 of 12
Models LP122A Series/LP123/LP255 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual For Models: LP122A LP122A-3100 LP122A-4000 LP123 LP255 Contents: Installation Instructio.
2 NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600 INST ALLA TION INSTRUCTIONS Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation.
LP12 2A SE RI E S/LP1 23 PU LL EY SELECTION AN D H ORSEPO WER R EQU IR EME N TS GP M PUM P PULLEY MO T O R PULLEY R PM 600 PSI 800 PSI 1000 PS I 1300 PS I 2000 P SI * 22. 3 12. 75" 3.95" 500 9.6 12. 7 15.9 20. 7 31.9 24. 7 12. 75" 4.35" 555 10.
L P2 55 PU LLEY SELECT ION A N D H O RSEPOWER R EQ UIREMENTS PUM P PULLEY MO T O R PULLEY R PM GPM 1000 PS I 1500 PS I 2000 PS I 2200 PS I 12. 75" 3.95" 500 13 9.3 13. 9 18. 6 20. 4 12. 75" 4.35" 640 16. 6 11. 9 17. 8 23. 7 26. 1 12.
5 Exploded V iew - LP122A Series/LP123/LP255.
6 ITEM PART NO. DESCRIPTION QTY. 1 07759 Crankcase 1 2 13000 Oil Filler Plug 1 4 06085 Crankcase Cover 1 5 07104 O-Ring 1 6 07186 Oil Sight Glass W/Gasket 1 8 06086 Oil Dipstick 1 9 01009 O-Ring 1 10 .
7 LP122A SERIES/LP123/LP255 PUMP REP AIR KITS V alve Assembly Kit LP122A. LP123, LP122A-4000, LP255 #09136 Item Part # Description Qty . 46A 07751 Valve Assembly, Complete 3 48A 12055 O-Ring 3 Plunger Packing Kit # 09477 (LP122A, LP123, LP122A-4000) (for pumps manufatured after 4/98) Item Part # Description Qty .
8 LP122A Series/LP123 - Repair Instructions 1. With a 30mm wrench, re- move the six (6) plugs (48) from the valve casing (43). Inspect the o-rings (48A) and replace if necessary. Remove the complete valve assembly (46A) by thread- ing a 12mm bolt into the spring retainer and pulling straight out.
9 11. If previously disassembled thoroughly clean all exposed surfaces on the spacer (29E) and all exposed threads on the plunger bolt (29C) and the steel plunger base (25). Threads MUST be free of old loc-tite and any other material such as oil, grease, etc.
10 12. Lubricate weep seal (36). Place, weep seal (36), and pressure ring (36A) into the seal sleeve (35). Assemble the o-ring (35A and 35B for LP255 only) onto seal sleeve and lubricate. 14. Press seal sleeve assembly into the manifold and seat firmly.
11.
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never fail, period.
デバイスGiant LP122A-4000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant LP122A-4000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant LP122A-4000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant LP122A-4000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant LP122A-4000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant LP122A-4000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant LP122A-4000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant LP122A-4000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant LP122A-4000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。