Triplex Ceramic Plunger Pump Operating Instructions/ Manual Mode l LP301 A-510 0 Contents: Installation Instructions: page 2 Specifications: page 3 Exploded View: page 4 Parts List / Kits: page 5 Repa.
2 INS TALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 Specifications Model LP301A-5100 PULLEY INFORMATION Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts. When selecting desired GPM, allow for a ±5% tolerance on pumps output due to variations in pulleys, belts and motors among manufactur- ers.
4 Exploded V iew - LP301A-5100.
LP301A-5100 PARTS LIST ITEM PART DESCRIPTION QTY 30 07779 Oil Scraper 3 31 07133 Oil Seal 3 35 13364-0100 Seal Sleeve 3 36 13238 Leakage Seal 3 37 13240-0100 Seal Case 3 38 07140 O-Ring, Seal Case 3 3.
6 1) Loosen and remove tension plugs (48) with a 36mm socket wrench. T O CHECK V AL VES NOTE: Always take time to lubricate all metal and non-metal parts with a light film of oil before reassembling. This step will help ensure proper fit, at the same time protecting the pump non-metal parts (elastomers) from cutting and scoring.
11) Remove the pressure ring (40A), v-sleeves (40), and support ring (40B), from the seal sleeve. Remove the pressure spring (41). Examine seals carefully and replace if worn. Clean surfaces of seal sleeves (35) which come in contact with the crankcase (1) and sealing surfaces of valve casing (43).
8 LP301A-5100 REPAIR INSTRUCTIONS 12) Check plunger surface (29B). If plunger pipe is worn out, loosen tension screws (29C) with a 15mm socket and pull off plunger pipe to the front. Clean front surface of plunger (29B) thoroughly. Apply a small drop of locktite to tension screw.
Pump Mounting Selection Guide Bushings 06496 - 35 mm H Bushing Pulley & Sheaves 07165 - 12.75 ” Cast Iron - 4 gr. AB Section Rails 07357 - Plated Steel Channel Rails (L=11.75 ” x W=1.88 ” x H=3.00 ” ) 9 LP301A-5100 REPAIR INSTRUCTIONS TO DISMANTLE GEAR END After removing valve casing (43) and plunger pipe (29B), drain the oil.
10 PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace.
LP301A-5100 DIMENSIONS - Inches (mm) 11.
GIANT INDUSTRIES, INC. , 900 N. Westwood Ave., P.O. Box 3187, Toledo, Ohio 43607 PHONE (419) 531-4600, FAX (419) 531-6836, www.giantpumps.com Copyright 2003 Giant Industries, Inc.
デバイスGiant LP301A-5100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant LP301A-5100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant LP301A-5100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant LP301A-5100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant LP301A-5100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant LP301A-5100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant LP301A-5100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant LP301A-5100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant LP301A-5100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。