Contents: Installation Instructions: page 2 Pump Specifications: pages 3-7 Parts List / Kits: page 8 Torque Specifications: page 8 Exploded View: page 9 Repair Instructions: page 10-11 Warranty Inform.
2 INST ALLA TION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 P21 7A- 31 00/5 100 HORS E POW ER REQUIREMEN TS RPM G PM 800 PS I 1200 PS I 1500 PS I 1700 PS I 2000 PS I 1725 1. 7 0.9 1. 4 1. 7 2. 0 2. 3 3000 3. 0 1.
4 P21 8A- 31 00/ 5 100 HO RS E POW ER REQUIREMEN TS RPM G PM 800 PS I 1200 PS I 1500 PS I 1700 PS I 2000 PS I 1150 2. 1 1.2 1. 7 2. 2 2. 5 2. 9 1450 2.
5 V olume ............................................................................................................ Up to 4.2 GPM Dischar ge Pressure .......................................................................................... Up to 2000 PSI Inlet Pressure .
6 Specifications Model P220A-3100/5100 V olume ............................................................................................................ Up to 4.7GPM Dischar ge Pressure ..............................................................
7 Specifications Model P221A-3100 NOTE: In order to drive the pump fr om the side opposite the present shaft extension, simply remove the valve casing from the crankcase and r otate the pumps 180 degrees to the desir ed position.
8 ITEM PART NO. DESCRIPTION QTY. 1 08300 Crankcase 1 2 08301 Oil Fill Plug with Gasket (P217-5100 & P221A-3100 1 2 08480 Dipstick 3 08302 Crankcase Plug Cover 1 3 A 07190 Drain Plug & Gasket 1 4 08005 O-Ring 1 5 08185 Oil Drain Plug 1 6 07188-0100 Screw, 316 S.
9 Exploded V iew - P200A-3100/5100 Series Unique for P221-3100 or.
10 REP AIR INSTRUCTION - P200A-3100/5100 SERIES Disassembly sequence of fluid end of P200A-3100/5100 series pump Note: Always take time to lubricate all metal and nonmetal parts with a light film of oil before r eassem- bly . This step will ensur e proper fit, at the same time pr otecting the pump nonmetal parts (i.
11 Disassembly sequence of the back end of the P200A-3100/5100 series pump. 1) Before you begin, drain the oil from the crankcase. 2 ) Remove the crankcase cover (3) and o-ring (4) from the crankcase (1). T o remove the crankshaft (13), remove the bearing cover (7) and sight glass (8).
GIANT INDUSTRIES, INC. , 900 N. Westwood Ave., P.O. Box 3187, Toledo, Ohio 43607 PHONE (419) 531-4600, FAX (419) 531-6836, www.giantpumps.com Copyright 1998 Giant Industries, Inc. P200A-3100/5100 DIMENSIONS (mm) 3/98 P200A-3100.PM6 GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc.
デバイスGiant P200A-3100/5100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant P200A-3100/5100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant P200A-3100/5100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant P200A-3100/5100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant P200A-3100/5100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant P200A-3100/5100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant P200A-3100/5100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant P200A-3100/5100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant P200A-3100/5100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。