334599A EN Repair ProConnect Displacement Pump For professional use only. Models: 17C487, 17 C488, 17C489, 17C 721 Important Safety Instructions Read all warnings and instructions in th is manual and related manuals. Be familiar with the controls and th e proper usage of the equipment.
Contents 2 334599A Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warnings 334599A 3 Warnings The following warnings are for the setup, us e, groundin g, maintenance, an d repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specifi c risks.
Warnings 4 334599A W ARNING SKIN INJECTION HAZARD High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection occurs, get imm ediate surgical treatment. • Do not aim the gun at, or spray any pe rson or animal.
Repair 334599A 5 Repair Trigger Lock Always engage the trigg er lock when sprayer is stopped to prevent the gu n from being triggered accidentally b y hand or if dropped or bumped. Pressure Relief Procedure 1. Engage trigger lock. 2. Turn ON/OFF switch to OFF position.
Repair 6 334599A 6. Turn pressure contro l to lowest setting. Disengage trigger lock. 7. Hold a metal part of the gun firmly to a grounded metal pail. Trigger the gun to relieve pressure. 8. Engage trigger lock. 9. Open any fluid drai n valves in system.
Repair 334599A 7 Dissemble Pump 1. Remove packing nut and throat adjustm ent spacer. Retaini ng nuts are not removable and not sold separately. 2. Unscrew cylinder from intake valve. 3. Dissemble intake valve. Clean and inspect. O-ring may require a pick for removal.
Repair 8 334599A 4. Tap piston rod out of cylinder with a hammer or flip over and tap piston rod out against a bench. 5. Unscrew piston valve from piston rod.
Repair 334599A 9 6. Clean and inspect parts. (The piston has a special thread locking/seali ng patch. Apply thread sealant to the threads. 7. Remove and discard throat packing and glands from th e cylinder.
Repair 10 334599A Assemble Pump 1. Soak leather packings in SAE 30W oil for one hour before assembly. 2. Install ball in piston rod. If thread seal- ant is applied to piston valve threads, ensure that none gets on the ball. 3. Torque to 27 ± 3 ft-lb (37 ± 4 N•m).
Repair 334599A 11 4. Assemble leather thro at packings soaked earlier. 5. Loosely install packing nut with o-ring onto cylinder. 6. Apply liberal amounts of g rease or oil to piston packings. 7. Grease top inch or two of piston rod that will go through the cylinder throat packings.
Repair 12 334599A 8. Grease o-ring and place on outside diameter ring gro ove. 9. Clean seat thoroughly. Reassemble intake valve with a seat, ball, and new o-ring. Seat may be flipped over and used on other side. 10. Torque to 60 ± 5 ft-lb (81 ± 7 N•m).
Repair 334599A 13 11. Install o-ring on to packing nut. Torque to 75 ± 5 ft-lb (101.7 ± 6.8 N•m) or addi- tional 1/2 turn from hand tight. 12. Storage ti24900a ti24901a.
Repair 14 334599A Throat Packing Adjus tment When pump packings begin to leak after much use, perform Pressure Relief Procedure , pag e 5 and tighten p acking nut down until leakage stops o r lessens. This allows approximately 100 gallons of additional operation be fore a repacking is required.
Parts 334599A 15 Parts 202 203 220 204 221 205 201 225 206 219 208 224 209 211 207 212 213 218 215 217 216 223 222 229 ti24903a.
Parts 16 334599A Parts List Ref. Part Description Qty. 201 24W617 ROD, displacement, includes 212 1 202* 180656 BUTTON, plug 1 203 193047 NUT, packing 1 204* 176757 GLAND, female, throat 1 205* 176754 GLAND, male throat 1 206 24W619 CYLINDER, pump includes retaining nuts 229 1 207* 105444 BALL, sst, 0.
Pump Installation 334599A 17 Pump Installation Pump installation inclu des securing the pump and connecting to the fluid inlet and outlet. 1. Connect outlet hose to pump. 2. Move pump displacement rod up or down until it slides into the connecting rod when the pump is slid i nto the drive housing.
Technical Specifications 18 334599A Technical Specifications PC Displacement Pump US Metric Maximum fluid working pressure 3300 psi 228 bar, 22.8 MPa Inlet/Outlet Sizes Fluid inlet size 1.
Graco Standard Warranty 334599A 19 Graco Standard Warranty Graco warrants all equipment referenced in this docu men t which is manufactured by Graco and bearing its name to be free from defects in material and work manship on the date of sale to the original purchaser for use.
All written and visual data containe d in this document reflects the latest p roduc t information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English.
デバイスGraco 17C489の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 17C489をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 17C489の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 17C489の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 17C489で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 17C489を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 17C489の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 17C489に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 17C489デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。