Gracoメーカー205626の使用説明書/サービス説明書
ページ先へ移動 of 18
Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 1996, Graco Inc. is registered to I.S. EN ISO 9001 10:1 Fire–Ball r 425 Pump For pumping petroleum–based lubricating fluids only .
2 308655 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 7 . . . . . . . . . . . . . . . . . .
3 308655 HAZARDOUS FLUIDS Improper handling of hazardous fluids or inhaling toxic fumes can cause extremely serious injury , even death, due to splashing in the eyes, ingestion, or bodily contamination. D Know the specific hazards of the fluid you are using.
4 308655 Installation The typical installation shown in Fig.1 is only a guide to help you select and install a pump; it is not an actual system design. Contact your Graco distributor for assistance in designing a system to suit your needs. Always mount the pump firmly to a bracket or a tank cover .
5 308655 Installation System Accessories CAUTION Do not hang the air accessories directly on the air inlet (E). The fittings are not strong enough to support the accessories and may cause one or more to break. Provide a bracket on which to mount the accessories.
6 308655 Installation Grounding Proper grounding is an essential part of maintaining a safe system. T o reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment.
7 308655 Operation Pressure Relief Procedure INJECTION HAZARD T o reduce the risk of serious bodily injury , including fluid injection or splashing in the eyes or on the skin, always follow this procedure whenever you shut off the pump, check or service any part of the system, install or change dispensing devices, and when you stop dispensing.
8 308655 Operation Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed, possibly damaging itself, and it may get very hot. CAUTION 7. Read and follow the instructions supplied with each component in your system.
9 308655 Air Motor and Throat Service Before Y ou Start D Be sure you have all necessary parts on hand. Repair Kit 238751 includes repair parts for the air motor and pump. Use all parts in the kit for the best results. Parts included in the kit are marked with one asterisk, for example (19*), in the text and drawings.
10 308655 Air Motor and Throat Service 10. Pull the piston assembly (27) from the air motor base (28), and set it aside. 1 1. Remove the throat bearing (36) with a 1 5/8-in. socket, remove the seal (2*), and wipe the seat clean with a cloth. 12. Remove the piston/base assembly from the vise, and set it upright on the workbench.
11 308655 Air Motor and Throat Service L 05612 25 16 23 15 T urn lock- wires up. Fig. 4 Cut off tops of poppets as indicated by dotted lines. 0.125” (3.18 mm) Cutaway View M 13 31 22* 21* 32* 21* 32* 27 28 32* 21* 17* 31 14 17* 21* 32* 26* 27 26* 14 19* 04422 12 13 15 Reassembly 1.
12 308655 Air Motor and Throat Service 12. Grease and reinstall the seal (2*) with the lips down, thread the throat bearing (36) into the air motor base (28), and torque the throat bearing to 30 to 40 ft-lb (41 to 54 N.m) using a 1 5/8-in. socket. 13.
13 308655 Displacement Pump Service Disassembly NOTE: Be sure you have all necessary parts on hand. Repair Kit 238751 includes repair parts for the air motor and pump. Use all parts in the kit for the best results. Parts included in the kit are marked with one asterisk, for example (19*), in the text and drawings.
14 308655 Parts List Model 205626, Series J Model 222065, Series B Model 222095, Series B W all-Mount Universal Pump 55-Gallon Drum Cover-Mount Pump 55-Gallon Drum Bung-Mount Pump Includes items 1 to 1 13 Includes items 1 to 1 13, 150, and 151 Includes items 1 to 1 13, 150,152, and 153 Ref No.
15 308655 Parts Drawing When assembling the fluid cylinder (1 10) over the assembled fluid piston (107, 109, 1 13), use the piston assembly tool included in repair kit 238751 and steps 21 through 23 on page 12 . 16 24 11 30 22* 21* 25 23 12 21* 17* 26* *19 27b 27a 31 15 13 27c 32* 29 3 7 18 36 1 *20 5 28 1 2 T orque to 30 to 40 ft-lb (41 to 54 N.
16 308655 Dimensions 1/2-in. npt air inlet 3/4-in. npt muffler port Model 205626 25.8 in. (655 mm) MODEL 205626, Series J 3/4-in. npt fluid outlet 18.4 in. (467 mm) 7.4 in. (188 mm) Model 222065 32.3 in. (820 mm) Model 222095 36.6 in. (929 mm) Note: For sealed tank mounting use gasket 192658.
17 308655 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 01234 56 FLUID FLOW––gpm (lpm) T est Fluid: 10-weight oil at 75 _ F (23.9 _ C) T o find fluid outlet pressure at a specific fluid flow and operating air pressure: 1. Locate desired fluid flow along bottom of chart.
18 308655 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
デバイスGraco 205626の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 205626をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 205626の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 205626の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 205626で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 205626を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 205626の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 205626に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 205626デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。