Instructions GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 1980, Graco Inc. is registered to I.S. EN ISO 9001 PLURAL COMPONENT Mixer Manifold 3000 psi (21.0 MPa, 210 bar) Maximum Working Pressure Model 215625 Series C Low V olume Mixer: 1/4 npt fluid outlet; for use in low volume applications, such as air spray urethanes.
2 307400 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 6 . . . . . . . . . . . . . . . . . .
3 307400 W ARNING INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
4 307400 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Follow the grounding instructions on page 5.
5 307400 Installation Grounding Proper grounding is an essential part of maintaining a safe system. T o reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment.
6 307400 Operation Start-up The mixer manifold was tested in oil, which was left in to protect the manifold. Before operating, thoroughly flush the manifold to prevent contamination of the fluids. Flushing Procedure CAUTION Be sure to label all fluid path parts “component A” or “component B” when disassembling them.
7 307400 Operation Be sure all fluid is thoroughly flushed from the hose after each use. Disassemble all other dispensing equipment, as nec- essary , and clean thoroughly . CAUTION T o prevent fluid from setting up in the dispensing equipment, flush the system frequently .
8 307400 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally . Fluid under high pressure can be injected through the skin and cause serious injury .
9 307400 Service Manifold Repair (See Page 10. ) W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Note: Repair kits are available for the manifold. Parts included in the kits are indicated with a †, for example (9†) See page 1 1.
10 307400 Parts 11 Ref No.13 Ball V alve 215622, Series B Low V olume Ref No.24 Ball V alve 215623, Series B High V olume 18* 22 15* 27 29 31 30 28 34‡ 33‡ 32‡ 33‡ 23 26 T orque twice to 60–70 in-lb.
11 307400 Parts Models 215625 and 215626, Series C Ref No. Part No. Description Qty . 1 100721 PLUG, internal hex; 1/4; 1/4 npt 2 2 104472 CAPSCREW, hex hd; 10–32 x 1–1/2 12 3† 105694 SEAL, shaf.
12 307400 Parts Model 241692 Series A 5765B 2 3 4 5 6 9 7 8 Ref No. Part No. Description Qty . 1 215626 MANIFOLD, mixer; see full parts and listing on pages 10 and 1 1 1 2 157676 UNION, swivel, 90 _ 1 3 155699 ELBOW, street 2 4 161037 FITTING, union, adapter 2 Ref No.
13 307400 T echnical Data Maximum working pressure 3000 psi (21.0 MPa, 210 bar) . . . . . . . . . . . . . . . . . . . . . Fluid port size Model 215625 1/4 npt(m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 307400 Dimensions Model 215625 Model 215626 Model 241692 A Overall Length 5.0 in (127 mm) 5.5 in (140 mm) 5.5 in (140 mm) B Overall Height 5.375 in.
15 307400 Notes head.notes.
16 307400 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by a n authorized Graco distributor to the original purchaser for use.
デバイスGraco 215626の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 215626をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 215626の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 215626の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 215626で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 215626を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 215626の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 215626に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 215626デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。