HEA VY -DUTY ST AINLESS STEEL Drum Agitator Heavy–duty , back–geared agitator for mixing and maintaining suspension of industrial coatings stored in 55–gallon drums.
2 308609 Symbols W arning Symbol W ARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
3 308609 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury .
4 308609 Installation W ARNING FIRE AND EXPLOSION HAZARD Always maintain a minimum of 1 in. clearanc e between rotating agitator parts and container to prevent sparks from contact.
5 308609 Installation With or Without an Elevator 1. Slide the agitator shaft through the large hole in the center of the drum cover (29). 2. Rotate the agitator so that the air motor is to the left of the shaft, as shown in Fig.
6 308609 Installation Installing the Siphon Kit See the Siphon Kit, Model 238250, Parts List on page 15. 1. Remove the top plug (5) and the bottom plug (20). 2. Replace the bottom plug (20) with the plain bearing (53), and tighten the bearing with a wrench.
7 308609 Installation Return T ube Kit 238884 (Accessory) Return T ube Kit 238884 is available as an accessory . The kit must be ordered separately . Refer to the sheet packed with the kit for installation instructions. Air Requirements For continuous use, the 3/4 HP (550 W) agitator air motor typically requires 3 to 4 cfm (0.
8 308609 Notes.
9 308609 Operation W ARNING MOVING P ARTS HAZARD T o reduce the risk of serious injury , including cuts, amputation of fingers by the agitator blades, and splashing in the eyes or on the skin, always shut off the agitator (disconnect the air line from the agitator) before you raise, check, or repair the agitator .
10 308609 Service Flushing the Air Motor W ARNING FIRE AND EXPLOSION HAZARD Do not use kerosene or other flammable solvents to flush the air motor . Flushing with flammable solvents could cause fire or explosion and result in serious injury or property damage.
11 308609 Service Cleaning the Agitator Shaft and Seal CAUTION Keep the agitator upright. Do not lay it on its side or upside down, or liquid may flow down the shaft and into the gear reducer area. If any material is on the shaft (6) within 1/2 in. (13 mm) of the housing (13), it must be removed to prevent damage to the bearing seal (14*).
12 308609 Service Servicing the Gear Reducer, continued Cleaning and Servicing 1. Clean any foreign material of f of the outside of the upper and lower housings (8 and 13). NOTE: Do not lose the two small thrust balls (4). One is in the upper housing (8), and one is in the lower housing (13).
13 308609 Notes.
14 308609 Parts Heavy-Duty Stainless Steel Agitator , Model 238157 (includes items 1–34) Heavy-Duty Stainless Steel Agitator with Siphon Kit, Model 240209 (includes items 1–4, 6–19, 21–34, 50.
15 308609 Parts Heavy-Duty Stainless Steel Agitator , Model 238157 (includes items 1–34) Heavy-Duty Stainless Steel Agitator with Siphon Kit, Model 240209 (includes items 1–4, 6–19, 21–34, 50–54) Ref No.
16 308609 Parts Heavy-Duty Stainless Steel Agitator , Drum Mounted, Models 24C293 and 24C522 (for drums with built–in shaft and blades) ti14500a DET AIL A 23 (See DET AIL A) REF 23 1 2* 2* 3 4 4 5 *.
17 308609 Parts Heavy-Duty Stainless Steel Agitator , Drum Mounted, Models 24C293 and 24C522 Ref No. Part No. Description Qty . 1 101 140 AIR MOTOR 1 2* 191004 BEARING, needle; 3/4” 2 3 190988 G.
18 308609 Parts Non-Siphon Agitator Package, Model 231413 Siphon Agitator Package, Model 231414 (shown) 100 101 102 107 104 103 106 05771B Ref No. Part No.
19 308609 T echnical Data Maximum air input pressure 100 psi (7 bar) . . . . . . . . . Motor power rating at 1200 rpm (shaft at 50 rpm), using 12 cfm (0.34 m 3 /min) 0.25 hp (186 W) . . . . . . . Maximum recommended shaft rpm 100 . . . . . . . . . . .
20 308609 Dimensional Drawings Heavy-Duty Stainless Steel Agitator , Model 238157 (shown) 05737 38 in. (965 mm) 10 in. (254 mm) 32 in. (813 mm) Siphon Kit, Model 238250 20 in. (508 mm) 05773 43 in. (1092 mm) 3 in. (76 mm) 1 Height of Model 240209 is the same as the Siphon Kit (see right).
21 308609 Mounting Hole Layout 2.0 in. (51 mm) TI0739 1.43 in. (36.3 mm) 1.40 in. (35.6 mm) 1.40 in. (35.6 mm) Three mounting holes, 0.375 in. (9.5 mm) diameter Center Hole, 2.125 in. (54 mm) diameter Counterbore, 2.92 in. (74.2 mm) diameter x 0.25 in.
22 308609 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
デバイスGraco 231414の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 231414をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 231414の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 231414の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 231414で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 231414を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 231414の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 231414に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 231414デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。