Gracoメーカー232079の使用説明書/サービス説明書
ページ先へ移動 of 24
Instructions–Parts List 308768J EN Important Safety Instructions Read all warnings and instructions in this manual and in 4–Ball Pump manual 3A1450. Save all instructions. W ALL MOUNT , 4–BALL 3:1 Ratio President r Pump Modules Used for low pressure, medium volume circulation of finishing materials.
2 308768 T able of Contents List of Models 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W arnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 6 . . . . . . . . . . . . . . . . . .
308768 3 Symbols W arning Symbol W ARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
4 308768 W ARNING PRESSURIZED EQUIPMENT HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury . D Do not point the gun at anyone or at any part of the body . D Do not stop or deflect leaks with your hand, body , glove or rag.
308768 5 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 10.
6 308768 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor .
308768 7 Installation Supplied Components Refer to Fig. 2 on page 9. W ARNING A red-handled bleed-type master air valve (1 1h) and a fluid drain valve (D) are supplied.
8 308768 Installation Installing the Pump Module The pump module consists of the pump mounted on the pump bracket, the air controls, back pressure regulator , hoses, and plumbing. NOTE: Refer to Fig. 2 on page 9, and to the Dimen- sion drawing on page 22 and the Mounting Hole Lay- out on page 23.
308768 9 Installation 7704c Fig. 2 A B C Detail of Air Controls 22 1 37 16 D 11 k 24 11 c 11 d E 15 5 14 12 F G 21 19 11 h 11 a 11 b 11 j 40 11 4 See Detail of Air Controls in upper left corner . Pump Module shown installed with a 239857 Supply Module (not included) 1 Ensure t hat there is 9 ft (2.
10 308768 Installation Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE AND EXPLOSION HAZARD on page 5. 1. Pump: use the ground wire and clamp (40, sup- plied). See Fig.
308768 11 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally .
12 308768 Operation Starting and Adjusting the Pump 1. Open all fluid shutof f valves (14, 15). Refer to Fig. 2 on page 9, and to Fig. 4. 2. Open the back pressure regulator (12). T urn the 3-way recirculation valve (19) to the circulation position. 3.
308768 13 Operation ti17807a Fig. 4 1 T orque packing nut (H) to 34–40 N S m (25–30 ft-lb). Packing nut is partially hidden. 15 5 14 21 19 11 h D 11 a 42 H 1 12.
14 308768 Maintenance Preventive Maintenance Schedule The operating conditions of your particular system determine how often maintenance is required. Estab- lish a preventive maintenance schedule by recording when and what kind of maintenance is needed, and then determine a regular schedule for checking your system.
308768 15 Maintenance 05998 201* 202* 203* 204* 205* 206* { 208 { 209 { 207* 210 { 21 1 } Model 1 13765 Air Filter/Regulator Shown 1 Lubricate w ith no. 2 lithium-base grease. 1 1 1 1 1 1 1 N P Repair Kit 239383 (includes items 201 to 207). For Part No.
16 308768 Parts Part No. 232078, Series B, stainless steel pump module Part No. 232079, Series B, carbon steel pump module (shown) Part No. 232081, Series B, stainless steel pump module B 10 9 1 B 38 .
308768 17 Parts Part No. 232078, Series B, stainless steel pump module Part No. 232079, Series B, carbon steel pump module (shown) Part No. 232081, Series B, stainless steel pump module NOTE: Part numbers vary by module. T o find the part number used in your module, read down the chart to find the desired ref.
18 308768 Parts Part No. 232078, Series B, stainless steel pump module Part No. 232079, Series B, carbon steel pump module Part No. 232081, Series B, stainless steel pump module NOTE: Part numbers vary by module. T o find the part number used in your module, read down the chart to find the desired ref.
308768 19 Notes.
20 308768 T echnical Data Part No. 232078, Series B, stainless steel pump module Part No. 232079, Series B, carbon steel pump module Part No. 232081, Series B, stainless steel pump module Category Data Maximum fluid working pressure 300 psi (2.1 MPa, 21 bar) Maximum air input pressure 100 psi (0.
308768 21 T echnical Data Fluid Outlet Pressure Chart 0 50 100 150 200 250 300 350 400 02468 1 0 1 2 1 4 PUMP DELIVER Y (T est Fluid: No. 10 Motor Oil) PUMP OUTLET PRESSURE 12 25 37 49 61 73 CPM 86 8 1 52 3 3 03 8 4 65 4 GPM l/min A B C 1.4, 14 0.7, 7 PSI 1.
22 308768 Dimensions 2 Mount the pump module so the top of the bracket is 4 to 5 ft (1.2 to 1.5 m) above the floor . 2 3 The suction hose is 6 ft (1.8 m) long. Do not stretch the hose tight; let it hang as shown, to assist fluid flow into the pump. 3 ti17807a Floor 33.
308768 23 Mounting Hole Layout 7687A 1.0 in. (25.4 mm) 4.0 in. (101.6 mm) 10.0 in. (254 mm) 5.0 in. (127 mm) 1 1 Check that t he bracket is level before bo lting it to the wall. 2 2 Mount the bracket so the top edge is 4 to 5 ft (1.2 to 1.5 m) above the floor .
24 308768 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
デバイスGraco 232079の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 232079をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 232079の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 232079の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 232079で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 232079を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 232079の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 232079に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 232079デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。