ST AINLESS STEEL, W A TERBASE COMP A TIBLE Fluid Pressure Regulators Used to regulate fluid pressure in low pressure systems only . Fluid Flow up to 3 GPM (1 1 liters/min) Instructions–Parts List 307212ZAC EN Important Safety Instructions Read all warnings and instructions in this manual.
2 307212 T able of Contents Models 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W arnings 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 6 . . . . . . . . . . . . . . . .
3 307212 Models Spring Operated Fluid Regulators Part No. Series Maximum Fluid Inlet Pressure, psi (kPa, bar) Regulated Pressure Range, psi (kPa, bar) Gauge Gauge Pressure Range, psi (kPa, bar) 214895 H 250 (1800, 18) 5–100 (34–700, 0.3–7) No n/a 214706 H 250 (1800, 18) 5–100 (34–700, 0.
4 307212 Notes.
5 307212 W ARNING PRESSURIZED EQUIPMENT HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury .
6 307212 Installation FLUID SUPPL Y INLET BALL V A L VE OUTLET BALL V A L VE PIPE NIPPLES BACK PRESSURE VA LV E FLUID RETURN AIR FIL T ER & REGULA TOR Spring Operated Installation Models 214895, 2.
7 307212 Installation Fluid pressure regulators are used for accurate, posi- tive control of the fluid pressure to spray guns, dis- pensing valves or atomizing heads. Regulators installed at circulating line take-offs or pumps are used to reduce main line pressure and maintain the desired fluid pressure to the spray gun or atomizing head.
8 307212 Operation CAUTION The new system must be cleaned and tested thoroughly before admitting fluid to the regulator to avoid contaminants clogging or damaging the regulator . Always use the lowest possible air and fluid pressures for your application.
9 307212 Operation 7. Adjust the fluid regulator to the desired setting. a. Spring Operated Regulators Only (see Fig. 3). The regulator can be adjusted in two ways: Using the male end (B) of the regulator key (24), turn the socket–head adjustment screw (19) fully clockwise .
10 307212 Notes.
11 307212 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment always make sure to Relieve the Pressure .
12 307212 Service Service of the Air Operated Regulators W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Shut off the pump. 2. Close the ball valve at the regulator ’ s air inlet.
13 307212 Service Models 214980 (shown) & 244375 29 10 13 23 7 1 17 22 26 18 9 15 16 4 20 40 6 21 3 NOTE: Numbers indicate tightening sequence. T ighten evenly to 7–10 in-lb (0.8–1.1 N m), then retorque to 125 in-lb (14 N m) three times, consecu- tively , to compensate for diaphragm relaxation.
14 307212 Service Service of the Spring Operated Regulators W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Shut off the pump. 2. Close the ball valve at the regulator ’ s fluid inlet.
15 307212 Service 10 Models 217314 and 221 1 18 Models 214895, 214706, 255374, and 24A082 21 12 13 22 25 17 26 3 15 16 23 40 6 9 18 4 20 1 7 10 21 12 13 22 17 26 3 15 16 23 40 6 9 18 4 20 1 5 2 4 6 1 3 BOTTOM VIEW PET NOTE: Numbers indicate tightening sequence.
16 307212 Parts 24 7 19 14 12 11 5 10 *21 *3 *9 27 28 23 4* *15 *16 *20 40* 1 6 18 26* 22* 17 13 Model 214895, Series H Without gauge. Includes items 1–26, 40 Model 214706, Series H With gauge. Includes items 1–40 Model 214706 only Ref No.
17 307212 Parts 24 7 19 14 12 11 5 10 *21 *3 *9 27 23 4* *15 *16 *20 40* 1 6 18 26* 22* 17 13 TI0037 Model 255374, Series A Model 24A082, Series A ISO pitch thread inlet and outlet (n ot compatible with US standard pitch – fluid housing coated with PTFE based polymer) Includes items 1–40 Ref No.
18 307212 Parts 24 7 19 14 12 11 5 10 *21 *3 *9 27 28 23 4* *15 *16 *20 40* 1 6 32 18 26* 25* 17 13 Model 221 1 18 only Model 217314, Series F With gauge. Includes items 1–32, 40 Model 221 1 18, Series E Without gauge.
19 307212 Parts Model 214980 Series F Includes items 1–40 *9 7 29 10 *21 *3 27 28 *15 *16 *20 40* 4* 23 1 18 26* 22* 17 13 6 Ref No. Part No. Description Qty . Ref. No. Part No. Description Qty . 1 100644 SCREW , soc hd cap; 0.
20 307212 Parts TI1697A Model 244375 Series B Includes items 1–41 *9 7 10 *21 *3 *15 *16 *20 40* 4* 23 1 18 26* *22 13 6 29 17 19 41 Ref No. Part No. Description Qty . Ref. No. Part No. Descri ption Qty . 1 100644 SCREW , soc hd cap; 0.
21 307212 Dimensions Model 244375: 3” (76.2 mm) All Other Models: 4.94” (125.5 mm) 1.76” (44.7 mm) 1.8” (46 mm) 3/8 npsm female INLET 3.65” (93 mm) DIA.
22 307212 T echnical Data Category Data Maximum Fluid Inlet Pressure 250 psi (1.8 MPa, 18 bar) Regulated Fluid Pressure Range Models 217314 & 221 1 18: 20–160 psi (0.15–1.1 MPa, 1.5–1 1 bar) Models 214706, 214895, 244375, 255374, & 24A082: 5–100 psi (30–700 kPa, 0.
23 307212 Performance Chart 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 0123 45 FLUID FLOW kPa bar p si gpm liters/min 0 10 20 30 40 50 60 70 80 90 100 0123 45 3.
24 307212 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
デバイスGraco 307212ZACの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 307212ZACをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 307212ZACの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 307212ZACの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 307212ZACで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 307212ZACを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 307212ZACの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 307212ZACに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 307212ZACデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。