312374 J EN Instructions-Parts Air Controls Integrated and 2-Button Interl ock Air Controls for use wi th Supply Systems. For professional use only . See page 2 for Mod el infor mation. Important Safety Instructio ns Read all warnings and instructions in this manual.
Conten ts 2 312374 J Contents Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Integrated Air C ontrols . . . . . . . . . . . . . . . . . . . .
Inte grat ed Air Contr ols 312374J 3 Integrated Air Controls Pressure Relief Procedure 1. Close th e air m otor slide r valve (E) and t he main a ir slider valve ( F). 2. Set the r am director val ve to DOWN. Th e ram wil l slowly drop. 3. Jog the dir ector valv e up and down to ble ed air from ram cylin ders.
Integrate d Air Cont rols 4 312374 J Replace Director Valve Numbers in parenthes es refer to F IG . 5. 1. Relieve pres sure. 2. Remove s crews (4a) and take o ff director valve. 3. Remove s pring (4c ), valve p late (4d), a nd o-ring (4b) . 4. Remove an d discard pin (4g) and fo ur valve seats (4e) with o -rings (4f).
Inte grat ed Air Contr ols 312374J 5 Replace Ram Air Reg ulator Numbers in parenthes es refer to Parts, page 10. 1. Relieve pres sure. 2. Remove fou r screws ( 7a) and take off the ra m air regulato r (7). 3. Replace o -rings (7b) o n back sid e of regulato r.
2-Button In terloc k 6 312374 J 2-Butt on Interlo ck Attach Roller Switch and Actuator 1. Attach r oller swi tch (133) t o bracket (13 2). Posi tion roller s witch to fa r back pos ition on the bracket and leave mo unting sc rews (144 ) loose. 2. Attach brac ket (132) to ram with sc rews (105) and washers ( 106).
2-Button In terlock 312374J 7 5. Tighten actuator brac ket to ro d using 4 sc rews (140 ) and brac ket clamps ( 139). 6. Adjust t he roller switch (133 ) out so it contacts actu- ator brack et (138), t hen tighten screws (144 ). 7. Tighten bracket (132 ) to ram wit h screws (10 5) and washers ( 106).
2-Button In terloc k 8 312374 J See F IG . 13 f or steps 9 - 14. 9. Inside 2-bu tton inter lock modul e, disconn ect elbow fittin g (6) and pu sh fitting s (7) fro m tee fitting ( 5). Remove pl ug (8) from a uxiliary ai r supply por t on back of inte grated ai r controls.
L20c Air Co ntrols 312374J 9 L20c Air Contro ls Pressure Relief Procedure 1. Close th e air m otor shutoff valve (E) and rem ove air line fro m air contro l coupli ng (x). 2. Set the el evator direc tor valve to DO WN. The r am will sl owly dr op. Disassembly 1.
Parts 10 312374 J Parts L20c Air Controls , 257613 Mounting s crews and lockwashe rs are in cluded wi th kit 25761 3. See man ual 31352 7. Front View Back View r_2891 05_31237 5_9a r_28910 5_312375 _9a2 212 218 211 209 213 216 201 205 204 206, 218 203 210 214 202 215 219 217 207 208 Ref.
Parts 312374J 11 Integrated Air Co ntrols Model 255650; D200s, D200, and D60 Model 257612; S20 ★ For D 200s, D200 , and D60 su pply sys tems only . ◆ ForS 20 suppl y systems only. 1 3 4 6 5 9 3 13 13 7 8 10 11 ti10774a 7a 7b 4b 4a 5 9 9 5 ★ 14 ◆ Ref.
Parts 12 312374 J Integrated Air Co ntrols Model 24C824; D200s and D200 1 4 9 3 13 7 8 10 11 ti10774a 7a 7b 4b 4a 5 Ref. Part Description Qt y . 1M A N I F O L D 1 3 1211 08 VALVE, s hutoff (inc ludes o-r ings and scr ews) 1 4 121107 VALVE, d irector (i ncludes 4a and 4b, plus a ll parts show n in F IG .
Parts 312374J 13 2-Button Interlock Kit Model 255719 (For D200 3- in., 55 gallon (200 liter) su pply syste ms with NXT 2200 , 3400 and 6500 Air Mo tors only) Model 255720 (For D20 0s 6.5 -i n., 55 gall on (2 00 li ter ) supp ly sy stem s with NXT 2200, 3400 and 6500 Air Mo tors only ) Model 257615 (For D60 3-in.
Pneumati c Schematic 14 312374 J Pneumati c Schemat ic Integrated Air Co ntrol Module Platen Pump Air Motor Ram Up Ram Down Pump Pressure Regulator Ram Pressure Regulator Air Motor Shutoff Ram Directi.
Pneumat ic Schem atic 312374J 15 Integrated Air Co ntrol Module with Optiona l 2-Button In terlock Platen Pump Air Motor Ram Up Ram Pressure Regulator Blow Off Valve INTEGRATED AIR CONTROL MODULE Air .
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco rese rves the right t o make changes at any time without notice. This m anual contains English. MM 312374 Graco H eadquarte rs: Min neapol is International O ffices: Bel gium, China, J apan, Korea GRACO INC.
デバイスGraco 312374Jの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 312374Jをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 312374Jの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 312374Jの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 312374Jで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 312374Jを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 312374Jの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 312374Jに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 312374Jデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。