312765 B Instr uctions - Schematics Mobile Spra y Rig For mobile spra ying or dispensing of epo xie s, pol yurethane foam, and polyurea coatings. Not for use i n explosive atmospheres.
2 312765B Contents Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Product Configur ator . . . . . . . . . . . . . . . . . . . . . . . 4 W arnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 0 Component Identification .
Relat ed Manuals 312765B 3 Related Manuals Graco Manuals These manual s can be f o und at www .graco . com. See Pr oduct Configurator on page 4 to deter mine whic h compo nents are i nstalled in your assembly . All manuals f o r insta lled compon ents are supplied wi th each S pra y Rig.
Product Co nfigurator 4 312765B Pr oduct Config urator An example of the product configurator would be the following co nfigurator c ode. The following par t nu mber fields apply for the Spray Rig par t numberi ng config urator fields.
Produ ct Configura tor 312765B 5 Code B Pa r t Air Compre ssor X U9101 0 None - F emale Q uic k Connect Fit ting Only A U9075 7 Rotary (Include s 40 kW , 3- Phase Ge nera - tor) No Air Conditioni ng, .
Product Co nfigurator 6 312765B Code F-G Pa r t Pump System NP - None 01 U90353 Husky 104 0 (2 Pumps with Sup ply Hoses), 20 ft 02 U90578 Husky 104 0 (2 Pumps with Sup ply Hoses), 28 ft 04 U90414 T2 (.
Produ ct Configura tor 312765B 7 30 U9082 0 Fusion C learShot, I ncludes RD000 0, Qty 2 Guns 31 U9082 1 Fusion C learShot, I ncludes RD010 1, Qty 2 Guns 32 U9082 2 Fusion C learShot, I ncludes RD020 2.
Product Co nfigurator 8 312765B Code Q-R Pa r t Heated Ho ses NH - None 01 U90715 160 ft, 200 0 psi, (3) 3 /8 with Fluid T emper- ature Sen sor , No Scuff- Guard, Non-assem bled 02 U90453 210 ft, 200 .
Produ ct Configura tor 312765B 9 37 U90722 160 ft, 350 0 psi, (4) 3 /8 with Fluid T emper- ature Senso r , Scuff-Guard, N on-assem - bled 38 U90462 210 ft, 350 0 psi, (4) 3 /8 with Fluid T emper- atur.
Warnings 10 312765B Wa r n i n g s The following warni ngs are for the setu p , use, groundi ng, mainte nance, and repai r of this eq uipment. The ex clama - tion point sy mbol aler ts y o u to a general war ning and the haz ard symbol ref ers to procedure- specific r isk.
Warnings 312765B 11 ELECTRIC SHOCK HAZARD Imprope r grounding, s etup , or usage of the syste m can caus e electr ic shock. • T ur n off and d isconnect power at main switch be f o re disconn ecting any cables and before ser vicing equipme nt. • Connect o nly to grounde d power source.
Compone nt Identification 12 312765B Compon ent Id entifica tion 20 ft T railer F IG . 1: Main Room H R G J F K L E C S T D A B N C M J P M Key : A Propo r tioner BA i r D r y e r C Chemi cal Dr ums a.
Componen t Identific ation 312765B 13 20 ft T railer , continued F IG . 2: Generator Room AA AC AB N TI1288 8b Key: AA Generator AB Ai r Conditione r A C Air Compressor AD Main Break e r AE Shore P ower Exten sion Cord AF Shore/Ge nerator P owe r Switch AD See P ower So ur ces on page 19 for a c loser view of which outlets Shore P ower supplies.
Compone nt Identification 14 312765B Single Propor tioner 28 ft T railer and T ruck Bo x F IG . 3: Main Room T D P C H G M R E J K L C J A F B N TI1288 4a TI128 83a The 18 ft truck bo x has a two-drum chemical rack instead of a three-dr um chemical rack.
Componen t Identific ation 312765B 15 Single Propor tioner 28 ft T railer and T ruck Bo x co ntinued F IG . 4: Generator Room N AA AB J TI12 885b 1 Only the 28 ft tr ailer has the gooseneck area. See P ower Sources on page 19 for a clos er vie w of which outlets Shore P ower supplies .
Compone nt Identification 16 312765B Dual Proportion er 28 ft T railer and 20-28 ft T ruc k Box F IG . 5: Main Room 20 ft T ruck Bo x Shown 20 ft T ruck Bo x Shown TI12 889a TI12890 a A F J K D J C T .
Componen t Identific ation 312765B 17 Dual Proportion er 28 ft T railer and 20-28 ft T ruc k Box, cont inued F IG . 6: Generator Room 20 ft T ruck Bo x Shown TI12891 b AB B AE N AC AA AJ 1 AD See P ower Sour ces on page 19 for a closer view o f which outlets Shore Po wer supplies.
Groundi ng 18 312765B Gr ounding The trailer must be grounded . In the ev ent of an elec tri- cal sho r t circuit, grounding reduces the risk of e lectri c shock by providing an escape wire for the electr ic cur- rent . When groun ding the traile r , ground to one of the bolt holes on the rear , s ide of gene rator bloc k.
Setup 312765B 19 Setup Po w e r S o u r c e s The trailer has two opti ons for power sources. Gene rator P ower uses the electr icity p ro vided by the generator to provide power to al l of the co mponents a nd outlets in the trailer except for the 12V l ights.
Setup 20 312765B Outlets P owered by Shore P ower in 28 ft T railer and Modified T ruc k Boxe s • The two-plug outl et in the m ain room to t he left of the ele ctric al panel, on the par tition wall • The outlet (W ) in the g enerator room F IG .
Setup 312765B 21 Sho re P ower Shore Po wer c an be used to provide power to cer ta in outlet s in the trailer . The powered out lets can be us ed to run low amperage ite ms . 1. T ur n main br eaker off . 2. T ur n generator of f . 3. T ur n Shore/Ge nerator P ower Switc h (AF) to the “OFF” positio n.
Setup 22 312765B Air Regulators Assembl y The left air pressure regulator o n the air re gulators assembly (F ) supplies air to the t ransf e r pump an d should b e set acc ording to ai r inlet recomm endations in the transfer pump manual . Pump flu id outlet pre ssure may v ar y bas ed on air inl et pressure.
Setup 312765B 23 Air Condition ing 1. V erify A ir Conditioni ng breaker is in the “ON” po si- tion. 2. See setup in str uctions in Air C onditioning manual. See Re lated Manuals on page 3. Breathable Air System 1. V erif y breathing air filter system is p lugged in .
Star tup 24 312765B Star tup Prepar e for Generato r Star tup 1. Ensure ma in brea ker f or the gene rator is in the OFF pos itio n. Th e main brea ke r is the on ly br eak er loca ted in the g enerator room . 2. T ur n Shore/Ge nerator P ower Switc h (AF) to the “GEN” positi o n.
Startup 312765B 25 Start T railer Components 12. T ur n on main breaker in the g enerator room. 13. V erif y v oltage and frequenc y displayed on the digit al v olta ge/amp mete r . W ith engin e at nor mal operati ng temperatur e and not un der load, voltage should be 220V +/- 1% and frequ ency sh ould be 60Hz +5%/- 2%.
Pres sure Re lie f Proc edure 26 312765B Pressure Rel ief Pr ocedure Generator pr essure must be relieved prior to perf or ming generator mai ntenance or repair . See generator man- ual. Air Pressure Relief 1. For rot a ry compressors, ope n ball valve on com- presso r .
Operat ion 312765B 27 Operation T railer Interior Lig hts 120V Lights The trailer i nterior lights on the walls an d the fluore scent light und er the ca binet (i f install ed) can be powered by either Gen erator or Sh ore P ower . T o u se these lights, setup Ge nerator P ower or Shor e P ower , see Setup on page 19 .
Shutdown 28 312765B Shutdo wn Shor t-T erm Shutdown 1. T ur n off propor tioner . Refer to propor t ioner ma nual f o r shutdown pr ocedure. See Rel ated Ma nual s on page 3. 2. Relie ve chemical pressure. See Pressure Relief Pr ocedure on page 2 6. 3.
Mainten ance 312765B 29 Mainte nance NO TE: Follow suggeste d maintena nce sch edule for all compo nents in their resp ective o wner ’ s manuals. See Related Manuals on page 3. T ro ubleshooting Contact your a uthorized G raco distr ibutor for ser vice a nd repai rs.
Simpl ifie d Elec tric al Sch emati cs 30 312765B Simplifi ed Electrical Sc hematics NO TE: Modifi ed truck box wiring v ar ies by trailer . Main Breaker , All T railers F IG . 18: Main Breake r , All T railers Connects to Generator Electrical Cabinet.
Simplifie d Electrical S chematic s 312765B 31 P ower Supply , All T railers F IG . 19: P ower Suppl y , All T railers See Electrical Panel wiring figure f or your trail er configuration.
Simpl ifie d Elec tric al Sch emati cs 32 312765B Electrical P anel 1-phase 20 ft a nd 28 ft Single Proportioner T railer s F IG . 20: Electrical Panel, 1-phase 20 ft and 28 ft Single Pr opor tioner 28 ft T railer s Connects to M ain Breaker . See M ain Breaker wiring, F IG .
Simplifie d Electrical S chematic s 312765B 33 3-phase 20 ft a nd 28 ft Single Proportioner T railer s F IG . 21: Electrical Panel, 3-phase 20 ft and 28 ft Single Pr opor tioner T railers Connects to Main Breaker . See Main Breaker wiring, F IG . 18 on page 30.
Simpl ifie d Elec tric al Sch emati cs 34 312765B Dual Pr opor tioner 28 ft T railer s F IG . 22: Electrical Panel, Dual Pr opor tioner 28 ft T railers Connects to Main Breaker . See Main B reaker wiring, F IG . 18 on page 30. See T rail er Wiring figure for y our trailer configuration.
Simplifie d Electrical S chematic s 312765B 35 T railer Wiring 20 ft T railers NO TE: Dashed lines indi cate items on other s ide of wall. F IG . 23: T railer Wiring, 2 0 ft T railers 2 See Electrical Panel wiring figure for y our trailer configuration.
Simpl ifie d Elec tric al Sch emati cs 36 312765B Single Pr opor tioner 28 ft T railer NO TE: Dashed lines indi cate items on other s ide of wall. F IG . 24: T railer Wiring, Single Proportioner 28 ft T railers 2 See Electrical Panel wiring figure for y our trailer configuration.
Simplifie d Electrical S chematic s 312765B 37 Dual Pr opor tioner 28 ft T r ailers NO TE: Dashed lines indi cate items on other s ide of wall. F IG . 25: T railer Wiring, Dual Proportioner 28 ft T railers 2 See Electrical Panel wiring figure for y our trailer configuration.
Simplif ied Pneumatic Sc hematic 38 312765B Simplif ied Pneuma tic Sc hematic Single Propor tioner T railer s/T ruc k Bo xes F IG . 26 T o Pr opor tione r (A) To P u m p ( L ) In Out To P u m p ( L ) .
Simplifi ed Pneumatic Schemati c 312765B 39 Dual Propor tioner T rail er s /T ru c k Bo xes F IG . 27 To P u m p ( L ) To P u m p ( L ) Air Dr yer ( B) In T o Prop or tioner (A) T o Pr opor tio ner (A.
Simpl ifie d Flui d Schema tics 40 312765B Simplified Fluid Sc hematics Single Proportion er T railers/T ruck Bo xes See Ci rculation and Return T ube Ki ts man ual.
Simplifi ed Fluid Schema tics 312765B 41 Dual Proportio ner T railers/T ruc k Bo xes, continued F IG . 29: System Circulation Key: CA Iso Drum CB I so Fl uid Li ne CC Is o Recirculation V a lv e CD Re.
Simpl ifie d Flui d Schema tics 42 312765B Dual Pr opor tioner T r ailers/T ruck Bo xes, continued F IG . 30: Machine Circulation Key: CA Iso Drum CB I so Fl uid Li ne CC Is o Recirculation V alve CD .
Dimensions 312765B 43 Dimensions F IG . 31: T op View C D 28 ft T rai ler Shown A TI12881 a.
Dime nsions 44 312765B F IG . 3 2: Side View Ref 20 ft T railer in. (cm) 28 ft T railer in. (cm) Modified Tr u c k B o x A (wid th) 102 (259) 102 (259 ) Va r i e s B (height, trailer le vel) Withou t Air Conditioni ng 129 (328) 129 (328) With Ai r Conditioni ng 135 (343) 135 (343) C (leng th) 240.
Tech nical Data 312765B 45 T ec hnical Data NO TE: See Related Manuals on p age 3. V oltag e, F requ ency 230V , 6 0 Hz Generator Ou tput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 kW , 1-phase or 3-phase (see Pr oduct Configurator on page 4) T railer M aximum Weight Capacity .
Graco Ohio Standard W arranty Graco warrants all equipment referenced in th is document which is manufactured b y Gr aco and bearing its nam e to be free from de fects in material and workmanship on the dat e of sale to the original purc haser f or use.
デバイスGraco 312765Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 312765Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 312765Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 312765Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 312765Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 312765Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 312765Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 312765Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 312765Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。