Repair-Parts EP2 EP2 EP2 Hose Hose Hose Pump Pump Pump 3A1940G EN Electric Electric Electric - - - powered powered powered hose hose hose pump pump pump for for for use use use in in in uid uid uid transfer transfer transfer and and and metering metering metering applications.
Contents Contents Contents Models .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 2 Warnings . .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 3 Troubleshooting .. .
Warnings Warnings Warnings Warnings The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specic risks.
Warnings WARNING WARNING WARNING ENTANGLEMENT ENTANGLEMENT ENTANGLEMENT HAZARD HAZARD HAZARD Rotating parts can cause serious injury. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Do not wear loose clothing, jewelry or long hair while operating equipment.
Warnings WARNING WARNING WARNING EQUIPMENT EQUIPMENT EQUIPMENT MISUSE MISUSE MISUSE HAZARD HAZARD HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the inuence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component.
Troubleshooting Troubleshooting Troubleshooting Troubleshooting NOTE: NOTE: NOTE: Check all possible remedies before disassembling the pump. Problem Problem Problem Cause Cause Cause Solution Solution Solution Inlet or outlet pipe diameters too small.
Troubleshooting Problem Problem Problem Cause Cause Cause Solution Solution Solution Chemical incompatibility. Consult your Graco distributor to see if you have the correct hose for your application. Normal wear. The hose may have failed due to normal wear.
Repair Repair Repair Repair Before Before Before You You You Start Start Start 1. Flush the pump. 2. Relieve the pressure. 3. Disconnect power to the pump. 4. Make sure the pump is electrically isolated. Unexpected operation of the pump can cause serious injury.
Repair Remove Remove Remove the the the Hose Hose Hose 1. See Figure 5, page 11. Remove the screws holding the motor fan cover (FC). Turn the fan by hand until the roller (102) stops at the bottom of the pump housing (1) in the 6 o’clock position.
Repair Remove Remove Remove the the the Roller Roller Roller 1. Using external snap ring pliers, remove the roller retaining ring (8) from the front of the eccentric shaft (7). 2. Pull the roller (102) off the shaft. It should slide off easily. 3. Inspect the inside and outside diameter of the roller (102), and replace it if worn or damaged.
Repair Remove Remove Remove the the the Eccentric Eccentric Eccentric Shaft Shaft Shaft 1. Using external snap ring pliers, remove the eccentric shaft retaining ring (8) from the motor output shaft (2). 2. Remove the eccentric shaft (7) from the motor output shaft.
Repair Reassembly Reassembly Reassembly Clean Clean Clean and and and Inspect Inspect Inspect All All All Parts Parts Parts NOTICE NOTICE NOTICE Use only genuine Graco replacement parts. Non-standard parts will void your warranty and may damage your equipment.
Repair Figure 7 Install the Motor Output Shaft and Eccentric Shaft Key Key Key for for for Figure Figure Figure 7 7 7 Note Note Note Description Description Description 1 Lips of the u-cup (4) must face toward the shaft bearings. 2 Lips of the u-cup (5) must face into the pump housing.
Repair Figure 8 Install the Roller, Hose, and Front Cover Key Key Key for for for Figure Figure Figure 8 8 8 Note Note Note Description Description Description 4 Torque to 115 in-lb (13.
Repair Install Install Install the the the Hose Hose Hose 1. Move the roller (102) by turning the motor fan until the roller reaches the 6 o’clock position. Figure 9 Roller in 6 O’Clock Position 2. Install one end of the hose (103) through the rear port of the pump housing on the left hand side when looking at it from the front.
Repair Install Install Install the the the Front Front Front Cover Cover Cover 1. Scrape all debris from the gasket mating surfaces on the front cover (12) and the pump housing (1), then clean with acetone or brake cleaner to remove any residue. This is critical to ensure a leak-free assembly.
Notes Notes Notes Notes 3A1940G 17.
Parts Parts Parts Parts EP2 EP2 EP2 Hose Hose Hose Pump Pump Pump Assembly Assembly Assembly EP2006 EP2006 EP2006 and and and EP2013 EP2013 EP2013 Pumps, Pumps, Pumps, Series Series Series A A A Inclu.
Parts Ref. Ref. Ref. No. No. No. Part Part Part No. No. No. Description Description Description Qty Qty Qty 101 24L887 ASSEMBLY, pump; see Bare Pump Assembly, page 20 .
Parts Bare Bare Bare Pump Pump Pump Assembly Assembly Assembly Model Model Model 24L887 24L887 24L887 Pump Pump Pump Assembly, Assembly, Assembly, Series Series Series A A A Includes items 1–23 20 3.
Parts Ref. Ref. Ref. No. No. No. Part Part Part No. No. No. Description Description Description Qty Qty Qty 1 --- HOUSING, pump 1 2 24K574 SHAFT KIT, output, motor; includes items 3, 4, 5, 6, 8, 18, a.
Parts Pump Pump Pump Matrix Matrix Matrix Model Model Model EP2006 EP2006 EP2006 Pumps Pumps Pumps With 6 mm ID Hose and Roller Installed Pump Pump Pump Part Part Part No. No. No. Pump Pump Pump Series Series Series Hose Hose Hose Kit Kit Kit (Ref. (Ref.
Parts Model Model Model EP2013 EP2013 EP2013 Pumps Pumps Pumps With 13 mm ID Hose and Roller Installed Pump Pump Pump Part Part Part No. No. No. Pump Pump Pump Series Series Series Hose Hose Hose Kit Kit Kit (Ref.
Parts Pump Pump Pump Kit Kit Kit Matrix Matrix Matrix Model Model Model EP2006 EP2006 EP2006 Pump Pump Pump Kits Kits Kits With 6 mm ID Hose (installed) and Roller (not installed) Pump Pump Pump Part Part Part No. No. No. Roller Roller Roller Kit Kit Kit (Ref.
Parts Model Model Model EP2013 EP2013 EP2013 Pump Pump Pump Kits Kits Kits With 13 mm ID Hose (installed) and Roller (not installed) Pump Pump Pump Part Part Part No. No. No. Roller Roller Roller Kit Kit Kit (Ref. (Ref. (Ref. 102) 102) 102) Hose Hose Hose Kit Kit Kit (Ref.
Parts Pump Pump Pump Part Part Part No. No. No. Roller Roller Roller Kit Kit Kit (Ref. (Ref. (Ref. 102) 102) 102) Hose Hose Hose Kit Kit Kit (Ref. (Ref. (Ref. 103) 103) 103) Hose Hose Hose Inner Inner Inner Material Material Material Hose Hose Hose Stripe Stripe Stripe Color Color Color Barbed Barbed Barbed Fitting Fitting Fitting Kit Kit Kit (Ref.
Parts Variable Variable Variable Frequency Frequency Frequency Drives Drives Drives (VFD) (VFD) (VFD) VFD VFD VFD Part Part Part No. No. No. Used Used Used With With With Pump Pump Pump Horsepower Horsepower Horsepower Input Input Input Voltage Voltage Voltage Output Output Output Voltage Voltage Voltage 16K905 EP2006 0.
Notes Notes Notes Notes 28 3A1940G.
Technical Data Technical Technical Technical Data Data Data EP2 EP2 EP2 Pumps Pumps Pumps U.S. U.S. U.S. Metric Metric Metric Maximum Fluid Working Pressure 125 psi 0.9 MPa, 9 bar See the Pump Matrix, page 22 , for the motor/gear ra- tio used on your pump: 0.
Graco Graco Graco Standard Standard Standard Warranty Warranty Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
デバイスGraco 3A1940Gの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 3A1940Gをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 3A1940Gの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 3A1940Gの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 3A1940Gで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 3A1940Gを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 3A1940Gの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 3A1940Gに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 3A1940Gデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。