Instr uctions-P ar ts Flo w Contr ol Modules 3A2097B EN Precisely regulates the flo w of material to a gun in an automatic proportioning system. For prof essional use only . Appro ved for use in e xplosive atmospheres onl y when used in conju nction with ProMix Electronic Pr opor tioners.
Related Manua ls 2 3A2097B Related Manuals ProMix Manuals in English Gr ounding Ground all components in y our system, as ex plained in yo ur ProMix Installation manua l. Ground a rem ote fluid regulator (used wit h Model 24H989 only) b y connectio n to a properly grounded fl uid hose.
Installation (Model 24H989) 3A2097B 3 Installation (Model 24H989) The intrinsically safe flow control module (FC) is required to use fl ow control in your syst em. It is for use with a remotely mounted , air-oper ated fluid regulator (FR, not included).
Service 4 3A2097B Service Bef ore Ser vicing 1. Flush s ystem and follow Pressur e Relief Proce- dure in your ProMix Repair-P a r ts manual. 2. Close main air shutoff v alve on air supply line and on ProMix. 3. Shut of f power (0 position). F IG . 3. 4.
Service 3A2097B 5 F IG . 4: 249849 Fl ow Control Modul e 604* 606 620‡ 607 603 605 619 618 621 605 614 601* 624 622 605 *623 *613 *610 *609 *612 *617 *616 611 615 TI12506a 602*‡ 619a 619b Flow direction 1 2 2 3 2 T orque to 8-10 in-lbs (0.9-1.1 N•m) T orque to 30-40 in-lbs (3.
Service 6 3A2097B Servicing the Pressure Sensor (Model 24H989 onl y) 1. Follo w Be fore Servicing , page 4. 2. Disconnect the pressure sensor (620) from the pressure sensor wire ha r ness (620b). F IG . 5. 3. Unscrew the pr essure sensor (620) from the pres- sure sensor fitting (62 6).
Service 3A2097B 7 F IG . 5: 24H989 Flo w Control Module 607 620 608 619 618 621 605 614 620b 603 602 611 605 619a 619b 626 624 620a 2 3 T orque to 30-40 in-lb (3.
Parts 8 3A2097B Pa r t s 249849 Flow Contr ol Module * P ar ts included in Regulator Service Kit 15G843. Purchase separately . ‡ P ar ts included in Sensor Service Kit 15G867. Purchase separately . P ar ts labeled --- are not a vailab le separately .
Parts 3A2097B 9 24H989 Flow Contr ol Module f or Remote Fluid Regulator P ar ts labeled --- are not a vailab le separately . Ref. No. P ar t No. Description Qty 602 --- O-RI NG; chemically resistant fluoroelastomer 1 603 112698 ELBO W , air inlet; 1/8 npt(m) x 1/4 in.
Dimensions and Mounting Hole Layou ts 10 3A2097B Dimensions and Mounting Hole La y outs Module A Overall Length in. (mm) Overall Width in. (mm) B Overall Height in. (mm) Mounting Dime nsions, Length (C) x Width (D) in. (mm) E Mounting Hole Size in. (mm) We i g h t lb (kg) 249849 Flow Control Module 7.
Technical Data 3A2097B 11 Te c h n i c a l D a t a Maximum fluid working pr essure . . . . . . . . . . . . . . . 190 psi (1.3 1 MP a, 1 3.1 bar) Maximum wor king air p ressure. . . . . . . . . . . . . . . . . 100 psi (0.7 M P a, 7 bar) Air supply . . .
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. Original instructions. This manual con tains English.
デバイスGraco 3A2097Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 3A2097Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 3A2097Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 3A2097Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 3A2097Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 3A2097Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 3A2097Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 3A2097Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 3A2097Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。