GrindmasterメーカーRAPS-330の使用説明書/サービス説明書
ページ先へ移動 of 12
ICB-400, ICB-300, P-430, P-330, RAP-430, RAP-330, RAPS-430, RAPS-330 OPER ATIONS MANUAL INS TALLATION WARNING: ELECTRIC SHOCK HAZARD! Installation of this appliance should be performed by qualified service personnel onl y . Improper installation could result in electrocution.
AMERICAN ME TAL WARE ® BREWERS INITIAL START-UP (cont’d) Once the appropriate selection is made, press the S TART switch on the touchpad to begin dispensing water through the sprayhead. Brew at least 1 batch for each timer setting. Check the level in the container to be sure the brew volume is correct.
AMERICAN ME TAL WARE ® BREWERS TEMPER ATURE AND BREW TIMING CONTROLS (Refer to Figure C) Temperature and brew timing are set by the dial and keypad located on the main controller. This controller is positioned inside the brewer housing and is accessed by removing the screws which fasten the access panel to the brewer.
STANDARD FE ATURES Three options are available on this equipment; these options are available independently of each other. The features are described below: Pre-infusion: This option enables the brewer to wet the grounds and then have a dwell period before the brew cycle is completed.
BY PASS ADJUSTMENT (Refer to Figure D) The bypass valve adjusts the amount of water that bypasses coffee grounds and dilutes the final brew. The factory setting is no bypass.
AMERICAN ME TAL WARE ® BREWERS TROUBLESHOOTING GUIDE Problem Possible Cause Solution ERROR MESSAGE FILLING PROBLEMS • Check system for water leaks. Correct any leaks and reset controller. • Thermistor failure or loose connections in thermistor circuit.
HE ATING PROBLEMS Tank does not heat • No electrical power to equipment. • No power to control board. • High electrode coated with lime or fault y. • Connection from control board to tank body fault y. • Connections from control board to heater relay fault y.
AMERICAN ME TAL WARE ® BREWERS TROUBLESHOOTING GUIDE (cont’d) • Contactor fault y. • Heater fault y. • Control board is fault y . • Heater fault y.
P roblem Possible Cause Solution • Brew valve fault y. • Touchpad fault y. • Controller fault y. • Check to see if there is 120 Vac across brew valve terminal. If there is 120 Vac across terminals and brew valve is not open,replace valve. • Check to see that touchpad connections to control board are secure.
AMERICAN ME TAL WARE ® BREWERS P-430, P-330, ICB-400, ICB-300 Part # A515027 A530-051 A531-072 A531-073 A535-071 A535-059 A536-018 A537-129 A537-154 A554-101 A712-066 A712-170 A712-174 DESCRIPTION Rela y , 12V d.c. Coil Controller Rela y , Powe r, 115V Coil Switch, Red Stop Element, Heating 6.
AMERICAN ME TAL WARE ® BREWERS NOTES Page 11.
WARRANTY For Models ICB-400, ICB-300, P-430, P-330 RAP-430, RAP-330, RAPS-430, RAPS-330 EFFECTIVE OCTOBER 1, 1998 GENERAL WARRANTY INFORM ATION Grindmaster Corporation maintains the highest standard of quality control in the manufacturing of American Metal Ware products.
デバイスGrindmaster RAPS-330の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Grindmaster RAPS-330をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGrindmaster RAPS-330の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Grindmaster RAPS-330の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Grindmaster RAPS-330で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Grindmaster RAPS-330を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGrindmaster RAPS-330の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Grindmaster RAPS-330に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGrindmaster RAPS-330デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。