FOR Y OUR SAFETY • Do not stor e or use g asoline or other f lammab le va pour s and liquids in the vicinity of this or an y other a ppliance. • Installa tion and ser vice m ust be perf or med b y a qualif ied installer , ser vice a g enc y or the g as supplier .
1” 1” ALCOVE INST ALLA TION LOCA TION Generally , the location selected should be as close to the wall as practical and as centralized with the piping system as possible.
– 2 – 1. COLD W A TER INLET 2. HOT W A TER OUTLET 3. GAS SUPPL Y MANUAL SHUT -OFF V AL VE 4. SEDIMENT TRAP 5. UNION - GROUND JOINT TYPE 6. FLOOR DRAIN 7. TEMPERA TURE & PRESSURE RELIEF V AL VE 8. GAS CONTROL 9. W A TER SUPPL Y T O METER 10. W A TER SUPPL Y T O HOME 1 1.
– 3 – Figure 3 - V ent Location Limit ations For a second or more direct vent unit, the dist ance between vent terminals must have a minimum of 1 foot. INSPECT SHIPMENT –– There may be hidden damage caused by transit. Check to be cert ain all p art s of the venting system, as shown in Figures 3A through 3M, are present.
SLOPE Figure 3 J Check the vent pipe’ s level or slope again, and adjust if required. – 4 – Figure 3 F Bend the 3 1/8” and 6” corrugated pipe all together toward the water heater ’ s flue connection.
– 5 – Inlet gas pressure to the appliance must not exceed the gas pressures marked on the rating plate; 7” W .C. for natural gas, 14” W .C. for L.P . gas. The minimum supply pressure for the purpose of input adjustment is 1” above manifold pressure.
– 6 – W ARNING Do not attempt to operate this water heater with the cold water inlet valve closed. Manually operate the T emperature and Pressure Relief valve at least once a year .
VI) LIGHTING AFTER INST ALLA TION W ARNING: T O A VOID POSSIBLE INJURY , FIRE AND EXPLOSION,READ THESE PRECAUTIONS BEFORE A TTEMPTING T O LIGHT OR RE- LIGHT THE PILOT . CHECK THA T THE HEA TER IS FILLED WITH W A TER AND THE VENTING SYSTEM IS UNOBSTRUCTED.
– 8 – LIGHTING INSTR UCTIONS FOR HEA TER WITH “R OBER TSHA W 220R” GAS CONTR OLS W ARNING: Should overheating occur or the gas supply fail to shut of f, turn of f the manual gas valve to the appliance. 1. ST OP! Read all safety labels on the water heater before operation.
– 9 – W ARNING If the water heater needs to be relit; 1. Open the inner door for at least 10 minutes and force some fresh air into the combustion chamber to clear any gas from the water heater and vent system. 2 Check the vent terminal for blockage.
– 10 – MAINTENANCE INSTRUCTIONS - GENERAL HOUSEKEEPING As a precaution against fire, and to maint ain an adequate flow of combustion air to the heater: • keep the appliance area clear and free f.
– 1 1 – CONTROL If the heater or the controls have been subjected to flooding, shut of f the gas at the manual shut-of f valve to the heater and call your gas comp any . The heater operates under a fully automatic control. Once the desired water temperature has been selected, the gas control will maint ain that temperature within close limit s.
See Rating Label Serial Number prefix for W arranty Code. Reduced warranty period applies to Newfoundland. W arranty Code: P R S T U V W Y S tandard W arranty Y ears: 3 5 6 7 8 9 10 12 Reduced W arran.
デバイスGSW PART NO.70999 REV.G (03-12)の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
GSW PART NO.70999 REV.G (03-12)をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGSW PART NO.70999 REV.G (03-12)の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。GSW PART NO.70999 REV.G (03-12)の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。GSW PART NO.70999 REV.G (03-12)で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
GSW PART NO.70999 REV.G (03-12)を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGSW PART NO.70999 REV.G (03-12)の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、GSW PART NO.70999 REV.G (03-12)に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGSW PART NO.70999 REV.G (03-12)デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。