Model 1981 POR T EXP ANDER This manual describes the installation procedures for the American Dynamics model 1981 Port Expander. The 1981 Port Expander is used to increase the number of RS-232 I/O ports on the 1650, 1995, 1996, and 2150 Systems. The Port Expander uses one I/O port to accept an input and then expands that one input to four outputs.
Information furnished by SENSORMATIC is believed to be accurate and reliable. However, no responsibility is assumed by SENSORMATIC for its use; nor for any infringements of other rights of third parties which may result from its use. No license is granted by implications or otherwise under any patent or patent rights of SENSORMATIC.
The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.
.
T able of Contents Description .............................................................1 Installation ..............................................................1 Power Source .........................................................1 Setup ..
.
DESCRIPTION The 1981 Port Expander is used to increase the number of RS-232 ports on the 1650, 1995, 1996, and 2150 Matrix Switching System CPUs. The Port Expander uses one CPU RS-232 port and expands that to four ports. These ports are for use with external RS-232 devices, such as keyboards.
SETUP Port Baud Rates As shipped all 1981 Port Expander units are configured as follows: Input Baud Rate - 1200 (Keyboard ports) Output Baud Rate - 4800 (System port) See Figure 2 below to locate the baud rate jumper pins on the main circuit board of the 1981.
CONNECTIONS Connections between the 1981 Port Expander and the 1650, 1995, 1996, and 2150 System CPUs, and between the 1981 and the keyboard(s) are discussed in the following pages and illustrated in the Appendix.
1981 to 1995 Connections The 1995 System has ten RS-232 ports. With the use of 1981 Port Expanders, you may expand the number of ports on the 1995 CPU to a maximum of forty. This type of connection is illustrated in Appendices B and C. The 1981 has five RS-232 ports.
1981 to 1996 Connections The 1996 has ten RS-232 ports. With the use of 1981 Port Expanders, the number of input keyboards that can communicate with the 1996 can expand to a maximum of forty. This type of connection is illustrated in Appendix D. The 1981 has five RS-232 ports.
1981 to 2150 Connections The 2150 has three RS-232 ports. When the 1981 Port Expander is used with the 2150, the number of inputs (keyboards) that can communicate with the 2150 can expand to a maximum of twelve. This type of connection is illustrated in Appendix E.
CONNECTIONS 1981 Connections for 2010DBVL Video Loss Detector Data Buffer Modules The 2010DBVL Video Loss Detector modules of the 2050 Switching Bays must communicate with only a single port on the 1996 CPU.
.
Appendix.
.
TYPICAL SYSTEM CONNECTIONS 1981 to 1650 APPENDIX A 1650 NOTE : THESE CONNECTIONS ARE TYPICAL OF ONE 1981 PORT EXPANDER . EACH RS232 PORT IS PROGRAMMABLE.
TYPICAL SYSTEM CONNECTION 1981 TO 1995, 9 - PIN CONNECTOR APPENDIX B 1678CM 1676 THREE CONDUCTOR SHIELDED BELDON 8770 OR EQUIVALENT XMIT RCD GND AC AC GND B W S CTS DTR DATA TP8059 7.
TYPICAL SYSTEM CONNECTIONS 1981 TO 1995, 25 - PIN CONNECTOR APPENDIX C 13 6 123 4 5 78 9 1 01 11 2 22 23 24 25 18 19 20 21 14 15 16 17 CPU'S TRANSMIT CPU'S RECEIVE GROUND THREE CONDUCTOR SHIELDED BELDON 8770 OR EQUIVALENT XMIT RCD GND AC AC GND B W S CTS DTR DATA TP8059 7.
1676 1996 APPENDIX D THREE CONDUCTOR SHIELDED BELDON 8770 OR EQUIVALENT 1 2 3 45 6 7 8 RED GREEN XMIT RCD GND AC AC GND B W S CTS DTR DATA TP8059 7.5 VOLTS AC 1.5 AMP 1678TB 1678CM THREE CONDUCTOR SHIELDED BELDON 8770 OR EQUIVALENT 1981 HP0047 4 RED GREEN JJ0007 ORANGE ORANGE TP8059 7.
1676 2150 RS232 PORTS MONITORS 12 3 4 5 123 ALARMS RELAY KEYBOARDS 12 3 4 2468 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 2 8 3 0 3 2 13579 1 1 1 3 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 3 1 CAMERAS -CODE- APPENDIX E THREE CONDUCTOR SHIELDED BELDON 8770 OR EQUIVALENT 1 2 3 45 6 7 8 RED GREEN XMIT RCD GND AC AC GND B W S CTS DTR DATA TP8059 7.
1996 to CPU THREE CONDUCTOR SHIELDED BELDEN 8770 OR EQUIVALENT 1 2 3 45 6 7 8 RED GREEN 123 4 5 6789 12345 6789 KBD d 1981 HP0047 12345 6789 JJ0007 1 2 3 45 6 7 8 RED GREEN HP0047 ORANGE ORANGE ** POR.
DATA LINE 120 VAC 50/60 Hz 257 497 1 241 DATA LINE IN OUT DATA LINE 1 2010R 2010R PORTS DATA LINE 12 PROG MON 12 3 456 78 9 1 0 1996 IN OUT To CPU 1981 DATA LINE TYPICAL SYSTEM CONNECTIONS 2050 Switch.
SPECIFICATIONS Supply Voltage: 1981 - 120VAC 50/60 Hz 1981X - 230VAC 50/60 Hz Power: 10 Watts, Nominal Temp. : 32 o F - 135 o F; 0 o C - 57 o C Humidity: Relative humidity between 9% - 95%, non-condensing Mounting: Free standing or half-rack mount with accessory kit (1 3/4" H) Weight: 3.
デバイスAmerican Dynamics AD1981の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Dynamics AD1981をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Dynamics AD1981の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Dynamics AD1981の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Dynamics AD1981で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Dynamics AD1981を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Dynamics AD1981の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Dynamics AD1981に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Dynamics AD1981デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。