Installation and Operating Instructions This manual describes the installation and operating procedures for the American Dynamics AD2096A Alarm Interface Unit.
The software/firmware furnished with this equipment is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software/firmware is furnished to the purchaser under a license for use on a single system.
The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.
.
CONTENTS Page DESCRIPTION .............................................................................. 1 FEA TURES .................................................................................... 1 INST ALLA TION ................................
.
DESCRIPTION The AD2096A Alarm Interface Unit (AIU) is used with American Dynamics Matrix Switching Systems to provide automatic callup of a camera to a monitor when a specific alarm switch/contact input is activated. Each AD2096A AIU is set up to identify the matrix system video input and preset scenes with which it will be associated.
SETUP Three 8-position DIP switches are used for AD2096A setup. The first two switches, S1 and S2, are located on the rear panel (see Figure 1, page 1). The top switch, S1, identifies the block of 64 alarm contacts (out of a possible 1024) which are connected to the AD2096A.
CONNECTIONS Alarm Inputs Eleven 12-pin connectors are provided on the rear panel of the AD2096A for alarm inputs. A mating screw-terminal connector, below, is supplied for each rear panel connector. Each connector is labeled with an alarm number (1 - 64), an "A", and a ground symbol.
OPERATION Power Sources Power is supplied via the appended 3-wire power cord. Power consumption is approximately eight watts. The AD2096A is configured for 120VAC, 50/60Hz, primary power source. Operating power voltages must be held within the 105V and 125V range.
T ypical System Connections.
.
ABCDEFGH ON OFF ON OFF SELECT ALARM POWER C O M INPUT OUTPUT ABCDEFGH N N C O C M 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 25 26 27 28 2.
ABCDEFGH ON OFF ON OFF SELECT ALARM POWER C O M INPUT OUTPUT ABCDEFGH N N C O C M 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 25 26 27 28 2.
AD1996 AD2096A AUX START RELAY OUTPUT SELECTS ALARM GROUP # 1-64, 65-128, 129-192 etc.... NORMALLY OPEN/CLOSED POSITION FOR ALARM INPUTS 1-8, 9-16, 17-24 etc.
C-5 TYPICAL SYSTEM CONNECTIONS AD2096A TO AD2150/2350 AD2150/2350 RS232 PORTS MONITORS 12 3 4 5 123 ALARMS RELAY KEYBOARDS 23 4 5 CAMERAS CODE 120V 60Hz BWS BWS BWS BWS 2468 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 2 8 3 0 3 2 13579 1 1 1 3 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 3 1 AD2096A SELECTS ALARM GROUP # 1-64, 65-128, 129-192 etc.
TYPICAL SYSTEM CONNECTIONS Cascading Multiple AD2096A Units AD2096A AD2096A 6003-0047-02 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 TERMINAL BOX 2113-0019-01 BROWN (GRD) GREEN RED GREEN BROWN (GRD) RED TERMINAL .
241 AD2010 Switching Bay PORTS 120V 60Hz DATA LINE 12 PROG MON 12 34 56 78 9 1 0 AD1996 1 AD2010DBVL Module 12 3 4 5 6 7 8 12 3 4 5 6 7 8 DATA LINE IN OUT SYNC 120 VAC 50/60 Hz 1 17 33 49 65 81 97 113.
Index.
.
I-2 INDEX AD2096A Alarm Input Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Alarm Relay Output Connection . . . . . . . . . . . . . . . . . . . . . 3 Alarm Response Operation . . . . . . . . . . . . . . . . . . . . . . . . . 4 Baud Rate Setup .
.
DECL ARA TION OF CONFORMITY According to ISO/IEC G uide 22 and EN45014 Manufacturer’s N ame: Sensormatic Electr oni cs Corporation Manufacturer’s A ddress: 1 Blue Hill Plaza 2 nd Floor Pearl River.
Sensormatic Video Systems Division One Blue Hill Plaza Pearl River, New York 10965 (845) 624-7600 Technical Support Center: 1-800-442-2225 FAX: 845-624-7685 8000-1819-01, Rev A December, 2000 Printed .
デバイスAmerican Dynamics AD2096Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Dynamics AD2096Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Dynamics AD2096Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Dynamics AD2096Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Dynamics AD2096Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Dynamics AD2096Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Dynamics AD2096Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Dynamics AD2096Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Dynamics AD2096Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。