FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-240g MODEL: HI300 10/07/08 Installer : Please complete the details on the back cover and leave this manual with the homeowner . Homeowner: Please keep these instructions for future reference.
Hampton HI300 Wood Cast Insert 2 Thank-you for purchasing a HAMPTON FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the HAMPTON DEALER in your area.
Hampton HI300 Wood Cast Insert 3 T ABLE OF CONTENTS SAFETY LABEL Safety Label For HI300.................................................. 4 UNIT DIMENSIONS Standard Faceplate ....................................................... 5 Cast faceplate....
Hampton HI300 Wood Cast Insert 4 SAFETY LABEL This is a copy of the label that accompanies your Hampton Insert . We have printed a copy of the contents here for your review . NOTE: Hampton units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Hampton HI300 Wood Cast Insert 5 UNIT DIMENSIONS 17-1/4” 9” 1 1-1/8” 1 1-3/8” 8-1/2" 21-1/2” 30” 30-7/8" 23-1/4” 23-3/4” 42-1/2” 41” 40” 7-3/4” NOTE: Before assembling your Insert, use these dimensions to ensure appropriate clearances will be met (refer to Masonry and Factory Built Fireplace Clearances section).
Hampton HI300 Wood Cast Insert 6 UNIT DIMENSIONS NOTE: Before assembling your Insert, use these dimensions to ensure appropriate clearances will be met (refer to Masonry and Factory Built Fireplace Clearances section).
Hampton HI300 Wood Cast Insert 7 INST ALLA TION CHIMNEY SPECIFICA TIONS Before installing, check and clean your chimney system thoroughly . If in doubt about its condi- tion, seek professional advice.
Hampton HI300 Wood Cast Insert 8 Clearance Diagram for Installations Side and T op facing is a maximum of 1.5" thick. Floor protection must be non-combustible, insula- tive material with an R value of 1.1 or greater . * Hearth thickness of 0.5" with k value = 0.
Hampton HI300 Wood Cast Insert 9 FLUE CONNECT OR BRACKET Package contains: 3 brackets and 6 screws. These brackets are to be used to hold the fl ue liner (not supplied) to the Insert and keep the connection. The brackets are screwed into the top of the Insert in the pre-punched holes and then screwed into the fl ue liner.
Hampton HI300 Wood Cast Insert 10 1) Positive Flue Connection with Cleanout 2) Direct Flue Connection with Cleanout 3a) Full Flue Liner (No Cleanout Required) Note: A clean-out door is sometimes required, by your inspector , to be installed when either the Positive fl ue connection or Direct fl ue connection method is used.
Hampton HI300 Wood Cast Insert 11 INST ALLA TION ST ANDARD CAST F ACEPLA TE INST ALLA TION 1 Left Side Faceplate 1 Right Side Faceplate 1 T op Faceplate 2 Side Mounting Brackets 4 1/4" - 20 x 1/2.
Hampton HI300 Wood Cast Insert 12 INST ALLA TION 4) Slowly slide the Mantel T op forward until it stops. Slide Mantel T op 5) Mount the T op Faceplate by carefully sliding the Mounting Plates on the Left and Right Side Faceplate thru the Retainers in the T op Faceplate.
Hampton HI300 Wood Cast Insert 13 INST ALLA TION 7) Location of Insulations a) Place 1 piece of Insulation behind the Mantel T op. b) Cut the second piece of Insulation in half, then install behind both the Left and Right Sides as shown. 8) The unit may now carefully be slid into fi nal position.
Hampton HI300 Wood Cast Insert 14 1. Ensure the unit is out from the fi replace opening by at least 4” before assembling the faceplate. 2. Remove the 4 bolts and washers on each side of the unit (shown below).
Hampton HI300 Wood Cast Insert 15 8. Install the left and right top corner faceplate mounting plates to the top surround using 2 bolts and washers per bracket. See diagram 7. T op Corner Faceplate Mounting Plates 9. Install the top surround by lining up the forks in the top surround to the installed capscrews on the mantel top.
Hampton HI300 Wood Cast Insert 16 Not using the 4th bolt location will help obtain a tighter fi t between the top surround and the left and right side surround. 11 . T ake the left or right side surround and slide the top bolt into the guide in the top corner faceplate mounting plate.
Hampton HI300 Wood Cast Insert 17 INST ALLA TION Rear View of Unit Stop! Read Carefully . Enamel & Cast components are very fragile. Use extreme care when handling. 4-1/2" - 4-3/4" boths sides rear inside edge to fi rebox. Important : V erify gap between cast and door did not change after rear adjustments have been made.
Hampton HI300 Wood Cast Insert 18 Backside of Fan Facia Shown. Y our fan should only be installed once the unit is in place in order to prevent any damage to the fan.
Hampton HI300 Wood Cast Insert 19 INST ALLA TION 1) Remove the Phillips screw , located on the top of the fan housing, which attaches the fan defl ector to the main fan body . 2) T ake off the 2 screws from the fan switch plate as- sembly , and remove it from the left casting face.
Hampton HI300 Wood Cast Insert 20 INST ALLA TION 10) Attach the thermodisc assembly to the mounting holes located on the right side of the base of the main fan body using the existing hardware - 2 bolts, nuts and washers. Important Note: On older fan units these holes may require drilling.
Hampton HI300 Wood Cast Insert 21 Pull Open Push Closed hand side, as far as possible and then bring it back into the hole on the right hand side. Use a pair of vise grips or pliers and tap it into place with a hammer . A tighter fi t will ensure the tube will not move when the unit is burning.
Hampton HI300 Wood Cast Insert 22 9) During the fi rst few hours it may be more dif fi cult to start the fi re. As you dry out your fi re brick and your masonry fl ue (if applicable), your draft will increase. 10) For those units installed at higher elevations or into sub-standard masonry fi replaces, drafting problems may occur .
Hampton HI300 Wood Cast Insert 23 ASH DISPOSAL During constant use, ashes should be removed every few days. Please take care to prevent the build-up of ash around the start-up air housing located inside the fi rebox, under the loading door lip. DO NOT ALLOW ASHES TO BUILD UP TO THE LOADING DOORS.
Hampton HI300 Wood Cast Insert 24 DOOR GASKET If the door gasket requires replacement, 7/8" diameter material must be used. A proper high temperature gasket adhesive is required. A gasket repair kit, Part # 846-570 is available from your local Hampton dealer .
Hampton HI300 Wood Cast Insert 25 LA TCH ADJUSTMENT The door latch may require adjustment as the door gasket material compresses after a few fi res. Removal of spacers will allow the latch to be moved closer to the door frame, causing a tighter seal.
Hampton HI300 Wood Cast Insert 26 MAIN ASSEMBL Y Part # Description 1) 942-681* Right Side Cast 936-238 Side Cast Gasket 2) 300-021 Flange Adaptor 3) 942-691* Ashlip 4) 300-006 Fan Clip 5) 300-023 Doo.
Hampton HI300 Wood Cast Insert 27 ST ANDARD CAST F ACEPLA TE Part # Description 300-921 Cast Faceplate - Metallic Black 300-925 Cast Faceplate - T imberline Brown 300-926 Cast Faceplate - Enamel Black 200) * T op Faceplate 201) * Left Side Faceplate 202) * Right Side Faceplate * Not available as a replacement part.
Hampton HI300 Wood Cast Insert 28 OVERSIZE CAST F ACEPLA TE Part # Description 300-931 Oversize Cast Faceplate - Metallic Black 300-935 Cast Faceplate - T imberline Brown 300) * T op Faceplate 301) * .
Hampton HI300 Wood Cast Insert 29 P ARTS LIST BRICK P ANELS Part # Description 180-960 Brick Set - Complete.
Hampton HI300 Wood Cast Insert 30 NOTES.
Hampton HI300 Wood Cast Insert 31 W ARRANTY Hampton Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd.
Hampton HI300 Wood Cast Insert 32 Printed in Canada Installer: Please complete the following information Dealer Name & Address: ______________________________________________ _____________________.
デバイスHAMPTON BAY HI300の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HAMPTON BAY HI300をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHAMPTON BAY HI300の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HAMPTON BAY HI300の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HAMPTON BAY HI300で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HAMPTON BAY HI300を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHAMPTON BAY HI300の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HAMPTON BAY HI300に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHAMPTON BAY HI300デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。