Hampton DirectメーカーHI300の使用説明書/サービス説明書
ページ先へ移動 of 24
FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-240e MODEL: HI300 07/18/06 Installer : Please complete the details on the back cover and leave this manual with the homeowner . Homeowner: Please keep these instructions for future reference.
Hampton HI300 Wood Cast Insert 2 Thank-you for purchasing a HAMPTON FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the HAMPTON DEALER in your area.
Hampton HI300 Wood Cast Insert 3 T ABLE OF CONTENTS SAFETY LABEL Safety Label For HI300 ................................................. 4 UNIT DIMENSIONS Unit Dimensions ............................................................ 5 INST ALLA TION Before Installing Y our Insert .
Hampton HI300 Wood Cast Insert 4 SAFETY LABEL This is a copy of the label that accompanies your Hampton Insert . We have printed a copy of the contents here for your review . NOTE: Hampton units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Hampton HI300 Wood Cast Insert 5 UNIT DIMENSIONS 17-1/4” 9” 1 1-1/8” 1 1-3/8” 8-1/2" 21-1/2” 30” 30-7/8" 23-1/4” 23-3/4” 42-1/2” 41” 40” 7-3/4” NOTE: Before assembling your Insert, use these dimensions to ensure appropriate clearances will be met (refer to Masonry and Factory Built Fireplace Clearances section).
Hampton HI300 Wood Cast Insert 6 INST ALLA TION CHIMNEY SPECIFICA TIONS Before installing, check and clean your chimney system thoroughly . If in doubt about its condi- tion, seek professional advice.
Hampton HI300 Wood Cast Insert 7 Clearance Diagram for Installations Side and T op facing is a maximum of 1.5" thick. Floor protection must be non-combustible, insula- tive material with an R value of 1.1 or greater . * Hearth thickness of 0.5" with k value = 0.
Hampton HI300 Wood Cast Insert 8 FLUE CONNECT OR BRACKET Package contains: 3 brackets and 6 screws. These brackets are to be used to hold the fl ue liner (not supplied) to the Insert and keep the connection. The brackets are screwed into the top of the Insert in the pre-punched holes and then screwed into the fl ue liner .
Hampton HI300 Wood Cast Insert 9 1) Positive Flue Connection with Cleanout 2) Direct Flue Connection with Cleanout 3a) Full Flue Liner (No Cleanout Required) Note: A clean-out door is sometimes required, by your inspector , to be installed when either the Positive fl ue connection or Direct fl ue connection method is used.
Hampton HI300 Wood Cast Insert 10 INST ALLA TION CAST F ACEPLA TE INST ALLA TION 3) Place Mantel T op onto the top of the fi rebox. Mantel T op 2) Secure the Left and Right Side Faceplate to the fi rebox by aligning the Mounting Holes with the Side Mounting Brackets taking care to align vertically while each side rests on the hearth.
Hampton HI300 Wood Cast Insert 11 5) Mount the T op Faceplate by carefully sliding the Mounting Plates on the Left and Right Side Faceplate thru the Retainers in the T op Faceplate. NOTE: Slowly lower the T op Faceplate into position; being careful not to damage the Mantel T op.
Hampton HI300 Wood Cast Insert 12 Backside of Fan Facia Shown. Y our fan should only be installed once the unit is in place in order to prevent any damage to the fan.
Hampton HI300 Wood Cast Insert 13 Pull Open Push Closed hand side, as far as possible and then bring it back into the hole on the right hand side. Use a pair of vise grips or pliers and tap it into place with a hammer . A tighter fi t will ensure the tube will not move when the unit is burning.
Hampton HI300 Wood Cast Insert 14 9) During the fi rst few hours it may be more diffi cult to start the fi re. As you dry out your fi re brick and your masonry fl ue (if applicable), your draft will increase. 10) For those units installed at higher elevations or into sub-standard masonry fi replaces, drafting problems may occur .
Hampton HI300 Wood Cast Insert 15 ASH DISPOSAL During constant use, ashes should be removed every few days. Please take care to prevent the build-up of ash around the start-up air housing located inside the fi rebox, under the loading door lip. DO NOT ALLOW ASHES TO BUILD UP TO THE LOADING DOORS.
Hampton HI300 Wood Cast Insert 16 DOOR GASKET If the door gasket requires replacement, 7/8" diameter material must be used. A proper high temperature gasket adhesive is required. A gasket repair kit, Part # 846-570 is available from your local Hampton dealer .
Hampton HI300 Wood Cast Insert 17 LA TCH ADJUSTMENT The door latch may require adjustment as the door gasket material compresses after a few fi res. Removal of spacers will allow the latch to be moved closer to the door frame, causing a tighter seal.
Hampton HI300 Wood Cast Insert 18 HI300 MAIN ASSEMBL Y Part # Description 1) 942-681* Right Side Cast 936-238 Side Cast Gasket 2) 300-021 Flange Adaptor 3) 942-691* Ashlip 4) 300-006 Fan Clip 5) 300-0.
Hampton HI300 Wood Cast Insert 19 HI300 CAST F ACEPLA TE Part # Description 300-921 Cast Faceplate - Metallic Black 300-925 Cast Faceplate - T imberline Brown 300-926 Cast Faceplate - Enamel Black 200.
Hampton HI300 Wood Cast Insert 20 P ARTS LIST HI300 BRICK P ANELS Part # Description 180-960 Brick Set - Complete.
Hampton HI300 Wood Cast Insert 21 NOTES.
Hampton HI300 Wood Cast Insert 22 NOTES.
Hampton HI300 Wood Cast Insert 23 W ARRANTY Hampton Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd.
Printed in Canada Installer: Please complete the following information Dealer Name & Address: ______________________________________________ _______________________________________________________.
デバイスHampton Direct HI300の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hampton Direct HI300をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHampton Direct HI300の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hampton Direct HI300の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hampton Direct HI300で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hampton Direct HI300を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHampton Direct HI300の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hampton Direct HI300に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHampton Direct HI300デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。