ページ先へ移動 of 16
990-1852A, 12/2004 User Manual English APC Smart APC Smart APC Smart APC Smart- - - -UP S UPS UPS UPS ® ® ® ® SC SC SC SC 250/450 VA 250/450 VA 250/450 VA 250/450 VA 110/120/230 Vac 110/120/230 Va.
.
1 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent blackou ts, browno uts, sags, and surges from reaching y our equipment. The uninterruptible power supply (UPS) filters sm all util- ity line fluct uations and isolates yo ur equipment from large disturbances by i nternally disconnecting from the utility line.
2 Rack-Mounting Two-post rack-mounting : Utilize the bracket holes that are offset 6.25”. Secure clip-nuts to the ra ck, and attach brackets with prov ided screws.
3 Tower Configuration Attention: Connect the battery before tower setup by r eferring to applicable steps in Rack- Mounting..
4 Wall Mounting Attention: Connect the battery before m ounting by referring to applicable steps in Ra ck- Mounting. To avoid a sa fety hazard, do not mount the unit on the wall with the bezel facing downwards, or with the di splay panel at the b ottom.
5 2: S T ART UP Connect Equipment to the UPS Rear Panels 110/120 V: 230 V: Note: A laser printer draws significantly more power than other types of equipment and may over- load the UPS. Connect the UPS to the Network (if Applicable) Serial Port Telephone/ Network Surge Suppression Ports Use only interface kits approved by APC.
6 3: O PERA TION Front Display Panel I NDICATOR D ESCRIPTION Online The UPS is supplying utility power to the connected equ ipment. On Battery The UPS is supplying battery power to the connected equipment. Overload The connected loads are drawing more th an the UPS power rating.
7 4: U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE A DJUSTED THROUGH P OWER C HUTE SOFTWARE F UNCTION F ACT OR Y D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automatic Self-Test Every 14 days (336 hours) Every 7 d ays (168 hours), On Startup Only, No Self-Test Set the interval at which the UPS will execute a self-t est.
8 N OTE : S ETTINGS ARE A DJUSTED THROUGH P OWER C HUTE SOFTWARE F UNCTION F ACT OR Y D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Synchronized Turn-on Delay 0 seconds 0, 60, 180 , 300 seconds Specify the time the UPS will wait after the return o f utility power before turn- on (t o a void br anch ci rcuit over- load).
9 5: S TORAGE AND M AIN TENANCE Storage Store the UPS covered in a cool, dr y location, with the battery fully charged. At -15 to +30 ° C (+5 to +86 ° F), charge the UPS battery ever y six months. At +30 to +45 ° C (+86 to +113 ° F), charge the UPS battery every three months.
10 6: T ROUBLESHOOTING , S HIPPI NG , AND S ERVICE Use the chart below to solve minor UPS installation and operation problems. Refer to www.apc.co m with complex UPS problems, and for battery runtime charts. P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION UPS WILL NOT TUR N ON UPS not connected to utility power supply.
11 P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION THE OVERLOAD LED IS ILLU MINATED AND THE UPS EMITS A SUSTAI NED ALARM TONE The UPS is over loaded. The connected equipment is dr aw- ing more VA than the UPS can sustain. The connected equipment exceed s the specified “maximum load.
12 Shipping and Service Prepare the UPS for shipping: Shutdown and disconnect any equipm ent attached to the UPS. Shut down the UPS, and disconnect the UPS from the utility power outlet. Discon nect the battery. If the UPS requires service do not return it to the dealer.
13 7: R EGULA TOR Y AND W ARRANT Y I NFORMA TION 110/120 V models This equipment has been tested and fou nd to comply with the limits for a Class A digital device, pur- suant to part 15 of the FCC Rules.
14 Limited Warranty American Power Conversion (APC) warrants its p roducts to be free from defects in materials and workmanship for a period of two years from the date of purchas e. Its obligation under this warranty is limited to repair ing or replacing, at its own sole option, any such defective products.
デバイスAmerican Power Conversion 110, 120, 230の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Power Conversion 110, 120, 230をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Power Conversion 110, 120, 230の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Power Conversion 110, 120, 230の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Power Conversion 110, 120, 230で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Power Conversion 110, 120, 230を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Power Conversion 110, 120, 230の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Power Conversion 110, 120, 230に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Power Conversion 110, 120, 230デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。