990-1851D 03/2007 User Manual English APC Smart-UPS ® SC 1000/1500 VA 110/120/230 Vac Tower/Rack-Mount 2U Uninterruptible Power Supply.
.
1 Introduction The APC Uninterruptible Power Supply (UPS) is de signed to prev ent blackouts, brownou ts, sags, and surges from reaching y our eq uipment. The uninterruptible powe r supply (UPS) filters small util- ity line fluct uations and i solates yo ur equipm ent from l arge disturbances by inter nally disconnect ing from the utility line.
2 Tower Configuration Note: Illustrations in this document may appear different than the actual hardware. " # $ % Mount the UPS in a Two-Post Rack " # Remove b attery bracket screws, battery bracket, an d batte ry.
3 $ % Note: For information on the four-po st rack- mounting ki t, see www.apc.com . & Reinstall battery, battery bracket, a nd screws. '.
4 2: S T ART UP Connect Equipment to the UPS Rear Panels 110/120 V: 230 V: • Note: A laser printer draws significantly more power than other types of equipment and may overload t he UPS.
5 Start the UPS 1. Plug the UPS into a two-pole , three-wi re, grounded rece ptacl e only. Avoi d using e xtension cords. 110/120 V mo dels : The power cord is attached to the UPS. The input p lug is a NEMA 5- 15P. 230 V models: The power cord is supplied in the UPS literature kit.
6 3: O PERA TION Front Display Panel 110/120 V 230 V I NDICATOR D ESCRIPTION On Line The UPS is supplying utility power to the conn ected equipment. On Battery The UPS is supplying battery power to the connected equipment. Overload The connected loads are drawing more th an the UPS power rating.
7 4: U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE A DJUSTED THROUGH P OW ER C HUTE SOFTWARE F UNCTION F ACT OR Y D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Self-Test Every 14 days (336 hours) Every 7 d ays (168 hours), Every 14 days (336 hours), On Startup Only, No Self-Test Set the interval at which the UPS will execute a self-t est.
8 N OTE : S ETTINGS ARE A DJUSTED THROUGH P OW ER C HUTE SOFTWARE F UNCTION F ACT OR Y D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Low Battery Warning 2 minutes PowerChute Business Edition software provides automatic, unat- tended shutdown when approxi- mately 2 minutes of battery oper- ated runtime re- mains.
9 5: S TORAGE AND M AIN TENANCE Storage Store the UPS covered in a cool, dr y loca tion, with th e battery fu lly charged . At -15 to +30 ° C (+5 to +86 ° F), charge the UPS batt ery ever y six months. At +30 to +45 ° C (+86 to +113 ° F), charge the UPS battery every three months.
10 6: T ROUBLESHOOTING , S HIPPING , AND S ERVICE Use the chart below to solve minor UPS installation and operation problems. Refer to www.apc.co m with complex UPS problems. P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION UPS WILL NOT TURN ON UPS not connected to utility power supply.
11 P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION THE OVERLOAD LED IS ILLU MINATED AND THE UPS EMITS A SUSTAINED ALAR M TONE The UPS is over loaded. The connected equipment is dr aw- ing more VA than the UPS can sustain. The connected equipmen t exceeds the specif ie d “maximum load.
12 Shipping and Service Prepare the UPS for shipping: Shutdown an d disconnect any equipm ent attached to the UPS. Shut down the UPS, and disconnect the UPS from the utility power outlet. Discon nect the battery. If the UPS requires service do not return it to the dealer.
13 7: R EGULA TOR Y AND W ARRANTY I NFORMA TION 110/120 V models This equipment has been tested and fou nd to comply with the limits for a Class A digital device, pur- suant to part 15 of the FCC Rules.
14 Limited Warranty American Power Conversion (APC) warrants its p roducts to be free from defects in materials and workmanship for a period of two years from the date of purchas e. It s obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products.
デバイスAmerican Power Conversion 1500 VA,の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Power Conversion 1500 VA,をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Power Conversion 1500 VA,の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Power Conversion 1500 VA,の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Power Conversion 1500 VA,で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Power Conversion 1500 VA,を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Power Conversion 1500 VA,の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Power Conversion 1500 VA,に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Power Conversion 1500 VA,デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。