American Power ConversionメーカーAP7902 AP7911の使用説明書/サービス説明書
ページ先へ移動 of 26
Switche d Rac k Power D istribution Un it AP7902 AP7911 Installation and Quick Start.
.
Contents Switched Ra ck PDU Insta llation and Quick Star t i Produ ct Descript ion and Inventor y . . . . . . . . . . . . . . . . . . . . . . 1 AP7902 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 AP7911 . . . . . . . .
ii Switched Ra ck PDU Insta llation and Quick Star t How to Dow nload Firmwa re Updat es . . . . . . . . . . . . . . . . . . . 17 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 AP7902/AP7 911 . . . . . . .
Switched Ra ck PDU Insta llation and Quick Star t 1 Pr oduct Description and Inventory AP7902 and AP79 1 1 are Switched Rack Powe r Distri bution Unit s (Rack PDUs) that dis tribute powe r to devices in the ra ck. The us er can tu rn on, turn off , or recycl e power bac k to the i ndividual ly contr olled outlet s.
Product Descripti on and In ventory 2 Switched Rack PDU Installation and Q uick Start Additiona l documentatio n The Rack PDU Us er’ s Gui de and the Rac k PDU Addendum a re avail able on the su pplied CD and on the APC W eb site: www .apc.co m . The User’ s Guide (.
Switched Ra ck PDU Insta llation and Quick Star t 3 How to Install the Rack PDU Installation guidelines • For a Ra ck PDU inst alled i n an enc losed co mmunicati ons rac k, the recommen ded maximum ambie nt tempera ture is 45° C ( 1 13º F).
How to Install the Rack PDU 4 Switched Rack PDU Installation and Q uick Start Attach cor ds to the tray Attach a cord to t he tray by loop ing th e cord and s ecuring i t to the tray , using a wi re tie ( provided) .
How to Install the Rack PDU Switched Ra ck PDU Insta llation and Quick Star t 5 For a r ecessed placement : use four flat -head scr ews (provid ed) through t he last four ho les of ea ch bracket .
6 Switched Rack PDU Installation and Q uick Start Operation Disp lay inte rfac e Link - Rx/Tx 10 / 100 Status Serial Port Rese t - W ar ning - OK - Overl oad B2 B1 TOT AL Amps Amps.
Switched Ra ck PDU Insta llation and Quick Star t 7 Quick Configuration Over v iew Y ou must configur e the fol lowing TCP/IP settin gs before the Rac k PDU can oper ate on a net work: • IP address .
Quick Configuration 8 Switched Rack PDU Installation and Quick Start APC Manageme nt Car d Wizar d Y ou can use the APC Management Card Wizard at a W indows ® 98, W indows NT ® 4.0, W indows 2000, or W indows XP computer to configure a Rack PD U. 1.
Quick Configur ation Switched Ra ck PDU Insta llation and Quick Star t 9 BOOTP . Y ou can use an RFC951-compli ant BOOTP serve r to configu re the TCP/I P settings f or the Rack PDU. If the BOOTP serv er is pro perly configur ed, the Rac k PDU’ s default setting ( DHCP & BOOTP ) fo r BOOT Mode causes it t o discove r the BOOTP server .
Quick Configuratio n 10 Switched Ra ck PDU Insta llation and Quick Sta rt DHCP . Y ou can use a RFC2131/RFC2132-c ompliant DHCP s erver to configur e the TCP/I P settin gs for the Rack PDU.
Quick Configur ation Switched Ra ck PDU Insta llation and Quick Star t 11 Local access to the contr ol console Y ou can use a l ocal comput er to conn ect to th e Rack PDU to ac cess the control console. 1. Select a serial port at t he local computer , and dis able any s ervice which uses that por t.
Quick Configuratio n 12 Switched Ra ck PDU Insta llation and Quick Sta rt 3. U se T el net t o acc ess t he Ra ck PD U at its ne wl y assi gne d I P addr ess. F or e xampl e: telnet 156.205.14.141 4. Use apc for bot h user name and pas sword. 5. See “Contr ol consol e” on this page to f inish the configur ation.
Switched Ra ck PDU Insta llation and Quick Star t 13 How to Access a Config ur ed Rack PDU Over v iew After t he Rack PDU is runn ing on yo ur network, you can use the interf aces summari zed he re to acce ss the uni t. W eb i nterf ace As your br owser , you can use Microsoft ® I nternet Ex plorer 5.
How to Access a Configured Rack PDU 14 Switched Ra ck PDU Insta llation and Quick Sta rt T elnet/ SSH Y ou can acces s the cont rol consol e through T elne t or Secur e SHell (SSH), depe nding on whic h is enabl ed. An Administ rator c an enable these ac cess metho ds through the T e lnet/S SH option of the Network menu.
How to Access a Configu red Rack PDU Switched Ra ck PDU Insta llation and Quick Star t 15 FT P / S C P Y ou can use FTP (ena bled by def ault) or Secure CoPy ( SCP) to tr ansfer new firmwar e to the Rack PDU, o r to acce ss a copy of th e Rack PDU’ s event l ogs.
16 Switched Ra ck PDU Insta llation and Quick Sta rt How to Recover Fr om a Lost Passwor d Y ou can use a local computer , a computer that connects to t he Rack PDU or other device t hrough the serial p ort to ac cess the c ontrol c onsole. 1. Select a serial port at t he local computer , and dis able any s ervice that us es that po rt.
Switched Ra ck PDU Insta llation and Quick Star t 17 How to Download Firmwar e Updates Y ou can use a l ocal comput er that co nnects to the Rack PDU through th e serial port on t he front o f the unit. 1. Select a serial port at t he local computer , and dis able any s ervice that us es that po rt.
18 Switched Ra ck PDU Insta llation and Quick Sta rt Specifications AP79 02/AP7 911 Electrical AP790 2 AP791 1 Nominal input voltage 120 V 208 V Acceptable input voltage ± 10% Nominal inp ut voltage .
Switched Ra ck PDU Insta llation and Quick Star t 19 W arranty and Service Limi ted w arr anty APC warrant s the Rack PDU to be free fr om defects in ma terials and workmanshi p for a per iod of two y ears fro m the date o f purchase .
20 Switched Ra ck PDU Insta llation and Quick Sta rt Life-Support Policy General po licy American Power Conversion (APC) doe s not recommend th e use of any of its p rodu cts in the follow ing situat .
Radio Fr equency Interfer ence USA — FCC This equi pment has be en teste d and found t o comply wit h the limits for a Class A d igital devic e, pursu ant to part 15 of the FCC Rules . These limit s are designed to pro vide reas onable pro tection against h armful interfe rence when the equi pment is ope rated in a commercial environme nt.
*990-1664* APC W orldwide Customer Support Customer support for this or any other AP C product is available at no char ge in any of the following ways: • V isit the APC W e b site to find answers to frequently asked questions (F AQs), to access documents in the APC Knowledge Base, and to submit customer support requests.
デバイスAmerican Power Conversion AP7902 AP7911の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Power Conversion AP7902 AP7911をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Power Conversion AP7902 AP7911の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Power Conversion AP7902 AP7911の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Power Conversion AP7902 AP7911で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Power Conversion AP7902 AP7911を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Power Conversion AP7902 AP7911の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Power Conversion AP7902 AP7911に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Power Conversion AP7902 AP7911デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。