1 Printed in U.S.A. Copyright 2008, Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 100-907F 4/08 RCT -ML T -II Remote Control Kits - Installation and Operating Instructions - INTRODUCTION The remote control system can be operated thermostati- cally or manually from the transmitter .
2 Figure 1 REMOTE RECEIVER Important: The remote receiver should be positioned close to front in right or left corner where ambient temperatures do not exceed 170º F . The remote receiver is powered by 1 10-120V AC. It plugs into a standard polarized duplex receptacle.
3 Figure 4. Figure 5. VARIABLE REGULATOR GAS CONTROL VALVE FLAME CONTROL SOLENOI D KNOB SCREW NUT VARIABLE REGULATOR JAM NUT VARIABLE REGULATOR SOLENOID WASHER WASHER PLUNGER Installing Flame Control Solenoid 1. Remove the screw and knob from the variable regula- tor and discard.
4 The remote receiver has a 3-position slide switch: OFF/ REMOTE/ON (see Figure 6). Figure 6. Remote Receiver TRANSMITTER Important: Before operating remote control, transmit- ter and receiver must have matching security codes. See section ‘Matching Security Codes’.
5 MA TCHING SECURITY CODES It may be necessary to program the remote receiver to the security code of the transmitter upon initial use, if batteries are replaced, or if a replacement transmitter is purchased from your dealer . T o program the remote receiver: 1.
6 Figure 8. Setting Button/Child Proof Lockout Setting ºF/ºC Scale The factory setting for temperature is degrees Fahrenheit ( ºF). T o change this setting to degrees Centigrade (ºC): 1. Remove the battery cover on the back of the transmit- ter and locate the “setting button” at the top center of battery compartment (see Figure 8).
7 Adjusting the Flame Height - Operates in ON or THERMO mode This remote control system allows the user to control the height of the FLAME when the gas valve is factory equipped with a FLAME CONTROLLER. 1. Press and release FLAME button to change fl ame height to HI (see Figure 7, Location #5), (a second fl ame icon appears).
8 6. Advance the SET temperature on the transmitter to a temperature of at least 2º F (1º C) above the ROOM temperature displayed on the LCD screen and the system fl ame will ignite. 7. Set the SET temperature to at least 2º F (1º C) below the room temperature and the system fl ame will extin- guish.
9 Figure 9. Intermittent Pilot Ignition (IPI) Wiring Diagram Figure 10. Standing Pilot Ignition Wiring Diagram TRAN SF ORMER 3V A C PLUG I N R E D BA T TERY P ACK THER MO ST A T WIRE AS SEMBL Y JUMPER.
10 Figure 12. Standing Pilot Ignition Wiring Diagram Figure 1 1. Intermittent Pilot Ignition (IPI) Wiring Diagram BLACK S2 ON OFF ON/OFF SWIT CH WHITE T2 RED T1 THERMO PILE GAS V AL UE BLACK S1 3/16.
11 Figure 14. Remote Control Standing Pilot Ignition Wiring Diagram Figure 13. Remote Control Intermittent Pilot Ignition (IPI) Wiring Diagram Remote Control Wiring Diagrams V ALVE GREEN ORANGE JUMPER.
デバイスHearth and Home Technologies RCT-MLT-IIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hearth and Home Technologies RCT-MLT-IIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHearth and Home Technologies RCT-MLT-IIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hearth and Home Technologies RCT-MLT-IIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hearth and Home Technologies RCT-MLT-IIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hearth and Home Technologies RCT-MLT-IIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHearth and Home Technologies RCT-MLT-IIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hearth and Home Technologies RCT-MLT-IIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHearth and Home Technologies RCT-MLT-IIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。