Heat & Glo LifeStyleメーカー7000XLSの使用説明書/サービス説明書
ページ先へ移動 of 25
1 - Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas Do not try to light any appliance. Do not touch any electrical switch. Do not use any phone in your building.
2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or components MA Y BE USED . This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance.
3 TABLE OF CONTENTS Safety and W arning Information ................................................ 2 Service Parts Lists ..................................................................... 4 Section 1: Approvals and Codes .........................
8 Appliance Certification The Heat-N-Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. Certification MODELS: 7000XLS, 6000XLSB LABORA T OR Y : Underwriters Laboratories TYPE: Direct V ent Gas Fireplace Heaters ST ANDARD: ANSI Z21.
9 2 Getting St arted Introducing the Heat-N-Glo Gas Fireplaces Heat-N-Glo direct vent gas fireplaces are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
10 Figure 1. Diagram of the 7000XLS and 6000XLSB.
11 3 Inst alling the Fireplace Step 1. Locating the Fireplace The diagram below shows space and clearance require- ments for locating a fireplace within a room. ABCD E 42 22 36 51 72 Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Front .
12 Figure 4. D-Series Direct V ent Component Specifications (5-inch inner pipe / 8 5/8-inch outer pipe) NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) A T EACH JOINT .
13 HORIZONT AL VENTING Kit No. H Max. Run DVK-01D DVK-01TRD 24" (610 mm) NOTE: 7000XLS & 6000XLSB models are not approved to use 45° elbows in corner installations. Use 90° elbows. Figure 6. Corner Installation Figure 5. V ent System Components and T ermination Kit s Step 3.
14 V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX.
15 Figure 9. V enting with three 90° elbows VENTING WITH THREE (3) 90° ELBOWS 1´ MIN. (305 mm) 2´ MAX. (610 mm) 6´ MAX. (1.82 m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 12´ MAX. (3.65 m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 18´ MAX. (5.485 m) 4´ MIN.
16 B. Inst alling V ent Component s The glass must be taken off again for positioning the logs when the unit is finally installed in place and finished around it.
17 2. Continue Adding V ent Component s W ARNING: INST ALLA TI ON OF THE 7000XLS FIREPLACE REQUIRES THE USE OF HEA T SHIELD 570-290 ABOVE THE FIRST 90 0 ELBOW IN THE VENTING SYSTEM THA T MAKES A TRANSI- TION FROM VERTICAL TO HORIZONT AL. (HEA T SHIELD NOT REQUIRED FOR 6000XLSB).
18 For V ertical Runs - The vent system must be supported every eight (8) feet (2.4m) above the fireplace flue outlet by wall brackets. T o install support bracket s for vertical runs: Attach wall brackets to the vent pipe and secure the wall bracket to the framing members with nails or screws.
19 For V ertical Runs - One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes. T o install firestops for vertical runs that pass through ceilings: Position a plumb bob directly over the center of the verti- cal vent component.
20 ! C. V ent T ermination For Horizont al T erminations - T o attach and secure the termination to the last section of horizontal vent: Rotate and interlock the ends as described at the begin- ning of the Installing V ent Components section. The termination kit should pass through the wall firestops from the exterior of the building.
21 V =VENT TERMINAL X =AIR SUPPL Y INLET =AREA WHERE TERMINAL IS NOT PERMITTED * 30 minimum for vinyl clad soffits. * * a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
22 For V ertical T erminations - T o locate the vent and install the vent sections: Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint. Make the outline of the roof hole around the centerpoint nail.
23 Step 4. Positioning, Leveling, and Securing the Fireplace Place the fireplace into position. Level the fireplace from side to side and from front to back. Shim the fireplace with non-combustible material, such as sheet metal, as necessary .
24 Figure 25. Gas Supply Line Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing. At the gas line access hole the gap between the supply piping and gas access hole can be plugged with non- combustible insulation to prevent cold air infiltration.
25 Step 8. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENT AL FIREPLACE OPERA TION. For Standing Pilot Ignition Wiring Appliance Requirements This appliance DOES NOT require 1 10-120 V AC to operate.
26 Step 9. Finishing Figure 28 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 2 and 3 for other fireplace clearances.
27 Inst alling the T rim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints between the finished wall and the fireplace top and sides can only be sealed with a 300° F .
28 Step 1 1. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace. Review safety warnings and cautions Read the Safety and Warning Information section at the beginning of this Installers Guide .
29 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season.
デバイスHeat & Glo LifeStyle 7000XLSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat & Glo LifeStyle 7000XLSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat & Glo LifeStyle 7000XLSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat & Glo LifeStyle 7000XLSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat & Glo LifeStyle 7000XLSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat & Glo LifeStyle 7000XLSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat & Glo LifeStyle 7000XLSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat & Glo LifeStyle 7000XLSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat & Glo LifeStyle 7000XLSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。