Heat & Glo LifeStyleメーカーST-38HV-AUの使用説明書/サービス説明書
ページ先へ移動 of 35
1 MODEL: ST -38HV -AU AUSTRALIAN GAS ASSOCIA TION APPROVED APPROV AL NUMBER 6027 THIS MANUAL MUST BE USED FOR INST ALLA TION AND RET AINED BY HOMEOWNER FOR OPERA TION AND MAINTENANCE.
2 IMPORT ANT : Read all instructions carefully before st arting installation. Failure to follow these installation instructions may result in a possible fire hazard and will void the warranty . Save this manual for future reference. Heat & Glo, a brand of Hearth & Home T echnologies, Inc.
3 T ABLE OF CONTENTS 1. 0 INST ALLA TION INSTRUCTIONS . ................................................................... 4 1.1 Locating the Heater ..................................................................................... 5 1.2 Framing the Heater .
4 Figure 1. Diagram of ST -38HV -AU 1.0 INST ALLA TION INSTRUCTIONS When planning a heater installation, it’s necessary to determine: • Where the unit is to be installed. • The vent system configuration to be used. • Gas supply piping. • Electrical supply wiring.
5 Clearance Requirements The top, back, and sides of the heater are defined by stand-offs. The minimum clearance to a perpendicular wall extending past the face of the heater is one inch (25mm). The metal ends of the heater may NOT be recessed into combustible construction.
6 Minimum Clearances from the Flue Pipe to Combustible Materials For V ertical For Horizontal Sections Sections At W all Firestop s T o p Bottom Sides T o p Bottom Sides 3 inches 1 inch 1 inch 1 inch 2-1/2 inches 1/2 inch 1 inch (75mm) (25mm) (25mm) (25mm) (64mm) (13mm) (25mm) Figure 3.
7 NOTES: 1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest part of the terminal. 2. Prohibited area below electricity meter or fuse box extends to ground level. 3. See clause 5.13.6.6 for restrictions on a flue terminal under a roofed area.
8 MODEL FLUE TERMINA TION APPROV ALS ST -38HV -AU DVK-01DA, DVK-01TR DVK-03DA DVK-TVCD TABLE 1 1.3 FLUE SYSTEM APPROV ALS AND INST ALLA TIONS This model is approved to use D-Series flue pipe components. A DVK-01DA, DVK-03DA or DVK-01TR Termination Cap must be used to terminate vent sys- tems in a horizontal position.
9 Figure 6 STRAIGHT UP VERTICAL FLUEING V (FT .) 40' MAX. (12.4 M) STRAIGHT OUT HORIZONT AL FLUEING H Max. Run 24" (610 mm) V CAP H NOTE: When the 45 0 elbow is attached horizontally , the supplied heat shield must be installed.
10 Figure 6 H V V H FLUEING WITH ONE (1) 90° ELBOW V (F T .) H (FT .) 4.5' MIN. (1.37m) 3' MAX. (.914m) 6' MIN. (1.86m) 4' MAX. (1.22m) 8' MIN. (2.4m) 5' MAX. (1.5m) 32' MAX. (9.75m) 5' MAX. (1.5m) V + H = 37’ MAX.
11 Figure 8 FLUEING WITH TWO (2) 90° ELBOWS V (FT .) H + H 1 (FT .) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.44m) 5’ MIN. (1.5m) 10’ MAX.
12 Figure 9 V 1 1 V H 1 1 H H V H 1 1 H 2 2 FLUEING WITH THREE (3) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 2´ MAX. (610 mm) 2´ MIN. (610 mm) 2´ MAX. (610 mm) 4´ MAX. (1.22 m) 3´ MIN. (914 mm) 2´ MAX. (610 mm) 6´ MAX. (1.86 m) 4´ MIN.
13 Figure 10 H 1 1 H V 1 1 V V 1 1 H 1 1 H V FLUEING WITH THREE (3) 90° ELBOWS V (FT .) H + H 1 (FT .) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX.
14 Installing Flue Components 1. Attach the First Flue Component to the Starting Collars T o attach the first flue component to the starting collars of the fireplace: • Apply a 3/8 inch (10mm) bead of stove cement around the inner pipe heater st arting collar .
15 For V ertical Runs The flue system must be supported every eight (8) feet (2.4M) above the heater flue outlet by wall brackets. T o install support brackets for vertical runs: • Attach wall brackets to the flue pipe and se- cure the wall bracket to the framing members with nails or screws.
16 ! • Drill a hole or drive a nail through this center point. • Check the floor above for any obstructions, such as wiring or plumbing runs. • Reposition the heater and flue system, if neces- sary , to accommodate the ceiling joists and/or obstructions.
17 Figure 20 1.4 CONNECTING THE GAS SUPPL Y The gas is introduced to the appliance on the left hand side. See Figure 20. After the gas pipe installation is complete, check care- fully all gas connections for leaks with a soap solution. DO NOT USE AN OPEN FLAME.
18 Figure 21 NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 • C RA TED WIRE. JUNCTION BOX JUNCTION BOX FAN BLUE BROWN YELLOW/GREEN BLUE BRN YW/GR BLK BLK TEMP . SENSOR SWITCH TEMP .
19 FIGURE 24 FIGURE 23 FIGURE 22 1.5.1 INST ALLING THE ELECTRICAL SERVICE TO THE JUNCTION BOX W ARNING: TURN ELECTRICAL POWER OFF A T THE CIRCUIT BREAKER BEFORE BEGINNING IN- ST ALLA TION. 1. Remove the electrical cover plate from the lower side of the heater .
20 LOG PLACEMENT INSTRUCTIONS LOG NUMBER 1 (SRV675-721): Position log #1 at the rear left corner of the grate against the three grate stops as shown. LOG NUMBER 2 (SRV6 7 5-722): Place log #2 so that the slot on the bottom of the log fits over the grate tab in the rear right corner .
21 LOG NUMBER 3 (SRV675-726): Position log #3 on the front right hand side of the grate against the 3 stops. LOG NUMBER 4 (SRV675-723): Place log #4 so that the slot on the bottom of the log fits over the grate tab on the front left corner of the grate.
22 LOG NUMBER 6 (SRV278-705): Place the "Y" end of the log #6 over the second rear grate bend and locate its top in the locating groove on log #2. LOG NUMBER 7 (SRV285-725): Position log #7 on the locating grooves on log #3 and log #4 as shown.
23 ! ! 2.0 OPERA TING INSTRUCTIONS This appliance is a balanced flue heater and is designed to operate with all combustion air being siphoned from the outside of the building and all exhaust gases ex- pelled to the outside of the building. W ARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
24 OPERA TING CAUTIONS • THIS APPLIANCE MA Y EXHIBIT A SLIGHT CAR- BON DEPOSITION. • DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE. • DO NOT USE OR STORE FLAMMABLE MA TERI- ALS NEAR THIS APPLIANCE. • DO NOT SPRA Y AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERA TION.
25 LIGHTING INSTRUCTIONS TO TURN OFF GAS APPLIANCE 1. Open the bottom grille. 2. Turn ON/OFF switch to "OFF". 3. Turn the valve control knob clockwise to the "Pilot" position, then depress knob and continue turning to "OFF" position.
26 FIGURE 30 FIGURE 29 2.4 F AN OPERA TION The accessory fan is wired in series with a speed con- trol switch and a temperature sensor switch. Set the speed control to an "ON" position and light the heater . The temperature sensor switch will automatically start the fan when the switch warms up—and stop the fan when it cools down.
27 3.1 REMOV AL OF COVERS FOR SERVICING A . Control Compartment Grille • Rotate the bottom grille down to access the gas controls. B . Trim door and Glass Door • Lift the front trim door up and out away from the appliance side surrounds. Replace the door when servicing is complete.
28 3.5 TROUBLESHOOTING - ST -38HV -AU With proper installation and maintenance, your new heater should provide years of trouble-free service. If you do experience a problem, refer to the T roubleshooting Guide below . This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
29 III. Pilot burning, no gas burner , valve knob "ON", "on-off" switch "ON". CORRECTIVE ACTION 3. Check thermopile with millivolt meter .
30 SYMPTOM I V . Frequent pilot outage problem. V . Pilot and main burner go out while being in operation. CORRECTIVE ACTION 1. Turn valve knob to “ON”. Place ON/OFF switch to “ON”. Check with millivolt meter at thermopile terminals. Millivolt meter should read greater than 100 m.
31 SYMPTOM V I . Glass soots. VII. Flame burns blue and lifts off burner . POSSIBLE CAUSE D . Glass too loose and air tight gasket leaks in corners after usage. E . Bad thermopile F . Improper flue cap installation. A . Flame impingement on logs. B . Improper venturi setting.
32 Part number list on following page. 6 2 4 1 5 5 3 (NG , LP) Exploded Parts Diagram Service Parts ST -38HV -AU Beginning Manufacturing Date: 5/2000 Ending Manufacturing Date: ________ 7 8 9 10 11 13.
33 Service Parts List IT E M Descri pti on SER IA L # P A RT NUM BER 1 B ur ne r N G SRV675-710A 1 B ur ne r L P SRV675-71 1A 2 G lass D oor Assembly GLA-38H V -AU 3T r i m D o o r 675-1 13A 4 Base Re.
34 (NG , LP) Exploded Parts Diagram Service Parts ST -38HV -AU Beginning Manufacturing Date: 5-2000 Ending Manufacturing Date: ______ IT E M DESCRI PT I O N SERI AL # P A RT NUM BER 1 Wi re A sse mbl .
35 In order to presumptively establish the dates to which your HEAT & GLO Limited 10 Year Warranty runs, you must mail the completed warranty card to HEAT & GLO, a brand of Hearth & Home Technologies Inc., 20802 Kensington Boulevard, Lakeville, MN 55044, within 60 days of the date of fireplace installation.
デバイスHeat & Glo LifeStyle ST-38HV-AUの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat & Glo LifeStyle ST-38HV-AUをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat & Glo LifeStyle ST-38HV-AUの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat & Glo LifeStyle ST-38HV-AUの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat & Glo LifeStyle ST-38HV-AUで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat & Glo LifeStyle ST-38HV-AUを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat & Glo LifeStyle ST-38HV-AUの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat & Glo LifeStyle ST-38HV-AUに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat & Glo LifeStyle ST-38HV-AUデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。