C L I M A T E C O N T R O L C CHTSTB March 2011 Replaces C C-HTSTB, Dec 2008 www .cold y oucancounton.com A I R C O O L E D C O N D E N S I N G U NI T 1 / 2 T O 6 H P I ND OO R A ND O UT DO O R .
2 C H T 030 L 6 C F M odel C ompressor A pplication E quiv . HP T emp . R efrigerant V oltage I dentier C = Climate Control H = Hermetic S = Semi–herm.
3 F eatures & Benets Typic al Outdoor Hermetic Unit Typic al Outdoor Unit with throwaw ay liquid-line lter and sight glass Typic al Outdoor Hermetic Unit with liquid lter drier and sight .
4 Options Electric al options: Outdoor Indoor Stock Adjustable low pr essure contr ol for medium temp . comp . Option Option N/A Air or electric defrost timer only Option Option 1/2-3 HP low temp .
5 HERMETIC COMPRESSORS P erformance Data - High T emperature (R-404A/507) R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 40°F 35°F CH*005H6 RST45C1E 8,910 8,150 CH*.
6 HERMETIC COMPRESSORS P erformance Data - Extended T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ † = RS compressor not suitable for R-507 R-404A/507 Model Compresso.
7 HERMETIC COMPRESSORS P erformance Data - Lo w T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empe.
8 HERMETIC COMPRESSORS P erformance Data - Medium & High T emperature (R-22) * = T for Outdoor, N for Indoor , S for Beacon II™ Hermetic C ompressors R-22 Mo del Compr essor Capacity BTUH @ 90°.
9 HERMETIC COMPRESSORS Unit Specications Electrical Data Model Fig . ++ Compressor Connections (ID) Receiver 90% F ull Lbs. F an(s) Dimensions Net Wt. Lbs. Sound Data dBA † Liquid Suction D (In.) W (In.) H (In.) CH*005H2 A AR T82C1 3/8 1/2 6.0 1 28-1/4 23-3/4 17-1/4 135 67 CH*008H2 A RS64C2 3/8 1/2 6.
10 Model Number Part Number Po wer Supply C ompressor Fan Motor MCA MOPD Evap . F an Amps Defrost Heater Amps V olts Ph Hz † RLA LRA Qty . HP FLA Air Elec. Air Elec. CH*040H2B CR53KQ-PFV 208-230 1 60 26.0 140.0 1 1/3 3.5 36.0 48.0 50 60 12.0 35 CH*040H2C CR53KQ- TF5 208-230 3 60 16.
11 * = T for Outdoor, N for Indoor , S for Beacon II™ R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 40°F 35°F 30°F 25°F 20°F 10°F 0°F -5°F CZ*020M6 ZS15K4E.
12 * = T for Outdoor, N for Indoor , S for Beacon II™ NOTE: The ZF c ompressor comes with liquid injection. R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 0°F -10.
13 * = T for Outdoor, N for Indoor , S for Beacon II™ R-22 Mo del Compr essor Capacity BTUH @ 90°F Ambient Suc tion T emperature 35°F 30°F 25°F 20°F 10°F CZ*020M6 ZS15K4E 22,080 20,420 18,800 .
14 R-22 Mo del Compr essor Capacity BTUH @ 90°F Ambient Suc tion T emperature 0°F -10°F -15°F -20°F -25°F -30°F -40°F CZ*020L6 ZF06K4E 11,610 9,400 8,380 7,450 6,590 5,840 4,590 CZ*025L6 ZF08K.
15 * = T for Outdoor, N for Indoor , S for Beacon II™ Per UL and NEC, RLA values hav e been calculated by dividing the Maximum Contin uous Current (MC C ) by 1.56. ^ Pow er supplied by customer . † Consult factory for 50 HZ applications . * = T for Outdoor, N for Indoor , S for Beacon II™ ++ = See Dimensional Drawings for details.
16 SEMI-HERMETIC COMPRESSORS P erformance Data - Medium T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suctio.
17 SEMI-HERMETIC COMPRESSORS P erformance Data - Lo w T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ ^ NRD1-040E Compressor is Single Phase & uses R -404A only.
18 SEMI-HERMETIC COMPRESSORS P erformance Data - Medium and High T emperature (R-22) * = T for Outdoor, N for Indoor , S for Beacon II™ R-22 Mo del Compr essor Capacity BTUH @ 95°F Ambient Suc tion.
19 SEMI-HERMETIC COMPRESSORS Unit Specications * = T for Outdoor, N for Indoor , S for Beacon II™ ++ = See Dimensional Drawings for details. † = Estimated sound pressure v alues are 10 feet from the unit.
20 SEMI-HERMETIC COMPRESSORS Electrical Data - Medium and High T emperature * = T for Outdoor, N for Indoor , S for Beacon II™ ^ Pow er supplied by customer . † Consult factory for 50 HZ applications. Model Number Part Number Pow er Supply Compr essor Fan Motor MC A MOPD Evap .
21 SEMI-HERMETIC COMPRESSORS Electrical Data - Low T emperature * = T for Outdoor, N for Indoor , S for Beacon II™ ^ Pow er supplied by customer . † Consult factory for 50 HZ applications. NOTE: P er UL and NEC, RLA values have been c alculated by dividing the Maximum Continuous Current (MC C ) by 1.
22 Dimensional Dra wings of Cabinets OUTDOOR A B C D 1/2, 3/4 AND 1HP 1-1/2 AND 2HP 3HP - AL TERNA TE CABINET 3, 4, 5 AND 6HP AIR FLOW AIR FLOW AIR FLOW AIR FLOW SUCTION LIQUID LIQUID SUCTION LIQUID L.
23 A B C D INDOOR 1/2, 3/4 AND 1HP 1-1/2 AND 2HP 3HP - AL TERNA TE CABINET 3, 4, 5 AND 6HP AIR FLOW AIR FLOW AIR FLOW AIR FLOW SUCTION LIQUID LIQUID SUCTION LIQUID LIQUID SUCTION FRONT VIE W OUTDOOR I.
A Brand of Heatcraft Refrigeration P roducts, LL C 2175 West P ar k Place Blv d. • Stone Mountain, GA • 30087 (800) 321-1881 ww w .heatcraftrpd.com C L I M A T E C O N T R O L Cold Y ou Can Count On Since produ ct improvem ent is a continuing eo rt, we rese rve the ri ght to make change s in specicati ons without noti ce.
デバイスHeatcraft Refrigeration Products CC-HTSTBの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heatcraft Refrigeration Products CC-HTSTBをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeatcraft Refrigeration Products CC-HTSTBの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heatcraft Refrigeration Products CC-HTSTBの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heatcraft Refrigeration Products CC-HTSTBで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heatcraft Refrigeration Products CC-HTSTBを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeatcraft Refrigeration Products CC-HTSTBの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heatcraft Refrigeration Products CC-HTSTBに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeatcraft Refrigeration Products CC-HTSTBデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。