Owner’ s Manual ©2002,2003,2004 Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road • PO Box 187 Waunakee, Wisconsin 53597 Phone: 608-849-3050 • Fax 608-849-7398 Web: www.
2 This owner’s manual is designed to assist owners and installers with the operation, maintenance and installation of your new water softener. It is our sincere hope that this manual is clear, concise and helpful to both owner and installer.
3 JOB SPECIFICA TION SHEET MODEL NO. ___________________________________________________________________________________________ *WATER TEST AT TIME OF INSTALLATION _______ Hardness CaCo 3 (gpg) _____.
4 SOFT WA TER BASICS Hardness Excess amounts of calcium and magnesium in water produce hardness. A water softener removes the majority of calcium and magnesium to produce softened water. Hardness is measured in terms of grains. (This grain weight is derived from the average weight of a dry grain of wheat.
5 Water Pressure: A minimum of 20 pounds of water pressure (psi) is required for regeneration. Maximum 120 psi. Water Quality: On rural water supplies there is often a problem with sand or sediment in the water. (This problem occasionally occurs in public water supplies.
6 • Do not use vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere. A silicon lubricant may be used on black o-rings but is not necessary. Avoid any type of lubricants, including silicone, on red or clear lip seals. • Do not use pipe dope or other sealants on threads.
7 PROGRAMMING Initial Start Up The initial start up will probably be done by the technician installing the softener system. If not, the following instructions will step you through the process. 1. Complete all plumbing connections: inlet, outlet, drain line and brine line.
8 Step 1 - Press SET CLOCK. Step 2 - Current Time (hour): Set the hour of the day using ▲ or ▼ buttons. AM/ PM toggles after 12. Press NEXT to go to step 3. Step 3 - Current Time (minutes): Set the minutes of day using ▲ or ▼ buttons. Press NEXT to exit Set Clock.
9 Regeneration Mode Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when the household is asleep. If there is a demand for water when the system is regenerating, untreated water will be supplied.
10 STEP 1S – Press NEXT and ▼ simultaneously for 3 seconds. If screen in Step 2S does not appear in 5 seconds the lock on the valve is activated. STEP 2S – Choose SOFTENING using ▼ or ▲ button. Press NEXT to go to Step 3S. Press REGEN to exit Softener System Setup.
11 STEP 8S – Select the time for the fourth cycle (which in this example is RINSE) using the ▼ or ▲ button. Press NEXT to go to Step 9S. Press REGEN to return to the previous step.
12 WA TER SOFTENER DISINFECTION The materials of construction of your water softener will not support bacterial growth nor will these materials contaminate a water supply.
13 TROUBLE SHOOTING PROBLEM CAUSE CORRECTION 1. ERROR followed by code number A. Control valve has just been serviced A. Press NEXT and REGEN for 3 seconds or unplug power source jack (black wire) and plug back in to reset control valve Error Code 1001 - Unable to recognize B.
14 TROUBLE SHOOTING PROBLEM CAUSE CORRECTION 9. Loss of resin. A. Backwash controller missing. A. Install backwash controller. B. Faulty distributor tube assembly. B. Check distributor tube assembly for cracks or holes. C. Air in water supply system. C.
15 Item Description Qty Part # 1 Control Center-Metered 1 60-PM1-ED (see pages 13-17 for detailed components) Control Center-Time Clock 1 60-PM1-TC 2 Top Diffuser 1 9-D1203 3&4 Mineral Tank Assemb.
16.
17.
.
19 Not Shown 15-V3191-01 Bypass 90º Vert. Assy. 1 15-V3151 Nut 1” Quick Connect 2 2 15-V3150 Split Ring 2 3 15-V3105 O-Ring 215 2 11* 15-V3191-01 Bypass Verticle Adpt.
20 INST ALLA TION FITTING ASSEMBLIES 1 15-V3151 Nut 1” Quick Connect 2 2 15-V3150 Split Ring 2 3 15-V3105 O-Ring 215 2 4 15-V3149 Fitting 1” PVC Male NPT Elb.
21 1 15-V3151 Nut 1” Quick Connect 2 2 15-V3150 Split Ring 2 3 15-V3105 O-Ring 215 2 4 15-V3164 Fitting 1” Plastic Male NPT 2 1-4 15-V3007-04 Fitting 1” Male NPT Asy.
22 PROMA TE 1 SYSTEM SPECIFICA TIONS ED-“ELECTRONIC DEMAND” TC-“TIME CLOCK” MODEL PM1-24ED PM1-32ED PM1-32-10ED PM1-48ED PM1-64ED PM1-96ED PM1-128ED PM1-160ED PM1-192ED PM1-24TC PM1-32TC PM1-32-10TC PM1-48TC PM1-64TC PM1-96TC PM1-128TC PM1-160TC PM1-192TC FACTORY PRESET MINUTES Backwash-1; Min 8 8 8 8 8 8 8 8 8 Brine; Min.
23 OPERATING PRESSURES Minimum/Maximum ................................................................................................................ ................. 20 psi-120 psi OPERATING TEMPERATURES Minimum/Maximum ...........................
24 73-351 6/04 - 2,500 Hellenbrand Water Conditioners, Inc., warrants to the original consumer/purchaser against defects in material and/or workmanshi p from the date of the original installation as follows: For a Period of FIVE YEARS : The control valve including electrical parts, internal parts, and valve body.
デバイスHellenbrand 1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hellenbrand 1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHellenbrand 1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hellenbrand 1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hellenbrand 1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hellenbrand 1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHellenbrand 1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hellenbrand 1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHellenbrand 1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。