HellenbrandメーカーIron Curtain Systemの使用説明書/サービス説明書
ページ先へ移動 of 28
For systems manufactured after October 1997 Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road • PO Box 187 Waunakee, Wisconsin 53597 Phone: 608-849-3050 • Fax: 608-849-7398 Web: www.
2 Congratulations on your purchase of one of the finest water treatment systems available today – the Iron Curtain System. This patented, non-chemical filter system, when properly applied will remove iron, manganese and/or hydrogen sulfide from your water supply.
3 INST ALLA TION DA T A Date of Installation _______________________________________ Model No.___________________________________ Address of Installation ______________________________________________.
4 IRON CUR T AIN the way to solve this problem is to use layers of media.” The advantages of a multi-media bed are: 1. Longer runs between backwash times. 2. Caking of the bed and breakthrough of turbidity are virtually eliminated. 3. Much higher service flow rates per square foot.
5 Operating Conditions The Iron Curtain System has been validated by the WQA under their S-200 Filter Standard for the reduction/removal of iron, manganese, and/or hydrogen sulfide.
6 Caution: The water pressure is not to exceed 70 p.s.i.; water temperature is not to exceed 110 ° F; conditioner cannot be subject to freezing conditions; conditioner cannot be subject to a negative pressure or vacuum.
7 Instructions for Adding IC pH Correction Media See Figures 1, 2 & 3 on page 8.. 1. Place Iron Curtain System on bypass. (Close inlet and outlet valves and open bypass valve.) 2. Relieve pressure by manually advancing timer to back- wash position (see page 10).
8 Due to existing plumbing conditions, you may want to choose an alternate installation configuration. Refer to Figures 2 and 3 below for alternate installation diagrams. FIGURE 1 Carefully place a pry bar (long screwdriver, wrench, etc.) between the screws and apply pressure clockwise until tight.
9 How T o Set T imer 1 How to set days on which water conditioner is to regenerate. Rotate the skipper wheel until the number "1" is at the red pointer. Set the days that regeneration is to occur by sliding tabs on the skipper wheel outward to expose trip fingers.
10 How T o Manually Regenerate Y our W ater F ilter At Any T ime Slowly turn the manual regeneration knob clockwise until the drive motor starts running. The movement of the manual regeneration knob engages the program wheel and starts the regeneration program.
11 How T o Set Regeneration Cycle Program 1 How to set the regeneration cycle program. The regeneration cycle program on your Iron Curtain Filter has been factory preset, however, portions of the cycle or program may be lengthened or shortened to suit local conditions.
12 Iron Curtain System Iron Curtain Wiring Diagram 1 2 3 WHITE BLK/WHT GREEN GREEN BLACK WH WHITE BLK/WHT BROWN YELLOW RED BLACK WHITE BLK/WHT BROWN YELLOW RED BLACK BLACK BLACK BLACK BLACK/WHITE TIME.
13 Iron Curtain T imer Assembly ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 ..................... 1 ............. 49-13870 ....... Timer Housing 2 ..................... 1 ............. 49-13011 ....... Cycle Actuator Arm 3 ..................... 1 .
14 Iron Curtain Control Drive Assembly 32 10 7 9 11 12 8 4 13 14 1 2 31 33 17 16 18 19 28 30 29 26 25 24 21 20 27 34 23 15 ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 ..................... 1 ............. 22-01 ............. IC Air Pump 2 ........
15 Iron Curtain Aeration Pump Item Part No. No. Description Qty. 1 .......... 74-625646 .............. Screw/Head .................................... 4 2 .......... 74-660631-504 ....... Head ............................................... 1 3 ......
16 Iron Curtain Aeration Pump Repair Instructions Air pump must be removed from tank and have power supply disconnected before proceeding. 1. Remove four front cover screws and remove front cover and cover gasket. 2. Remove four pump head screws and remove pump head.
17 IC-10 Series Control V alve Assembly ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 ..................... 1 ............. 49-11212NP .. Nickel Valve Body 2 ..................... 1 ............. 49-10757 ....... End Spacer 3 ..................... 6 .
18 1 IC-12 Series Control V alve Assembly 14 1 2 3 4 5 11 10 9 8 7 6 12 13 15 12 19 20 16 17 18 ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 .............. 1 ................... 49-14749-02NP .. Nickel Valve Body 2 .............. 1 ................
19 Instructions for Replacing Piston Assembly and Seal Kit Replacing Piston Assembly See pages 17 and 18 for Parts Diagrams. 1. Place Iron Curtain System on bypass. (Close inlet and outlet valves and open bypass valve.) See Figures 1, 2 & 3 on page 8.
20 Removing Power Head Removing Seal from Valve Body Piston Back Plate Seal Hook to Remove Seals Seal FIGURE 14 FIGURE 15 8. Using the puller, remove the first spacer. 9. Alternately remove the remaining seals and spacers in accordance with steps #7 and 8.
21 Removing Spacer from Valve Body Replacing Spacer in Valve Body Placing Seal in Brass Sleeve of Stuffer Removing Stuffer from Valve Body after Inserting Seal Puller to Remove Spacers Stuffer to Replace Spacers and Seals Spacer Stuffer Seal FIGURE 18 FIGURE 19 FIGURE 16 FIGURE 17 24.
22 IRON CURT AIN FLOW DIAGRAMS Step 1. Service Position Raw water enters the aeration- tank inlet, flows thru the inlet diffuser, thru a head of air, down thru the aeration tank, thru the pick-up tube, out the aeration head, into the filter control inlet, and down thru the multi-media bed.
23 Step 3. Bleeding Off the Aeration System The Iron Curtain Control Center automatically shifts the controller into the Aeration recharge cycle. The air bleedoff valve opens up and allows raw water and/or air to pass thru the bleed off tube in the aeration tank to the drain.
24 Step 5. Bleeding Off Excess Air The Iron Curtain Control Center automatically turns the air com- pressor pump off and allows both valves to remain open. The air bleedoff valve will bleed off any excess air which was pumped in during the previous step and the check valve in the recharge line prevents any backflow into the air compressor system.
25 1a. Clean or replace drain line flow control 2a. Check for minimum specified flow and pressure requirements of filter system 3a. (Generally will only plug with the presence of iron bacteria) Clean aeration assembly and shock treat the water supply with chlorine as needed to control iron bacteria 4a.
26 Complaint Problem Cause Solution A. Dirt lodged under seat of valve B. Faulty or defective relief valve A. This can be expected when water is aerated under pressure A. See complaint #1 problem A & B A. Inlet check valve not sealing A. Reduced pressure in distribution system A.
27 Winterizing Iron Curtain Systems (Optional) In certain climates where houses and/or cottages are not heated during the winter months, Iron Curtain Systems must have the water removed from them to protect from damage due to freezing. Following are instructions for “winterizing” Iron Curtain Systems.
28 73-510 7/03-2500 IRON CURT AIN FIL TER SYSTEMS LIMITED W ARRANTY Hellenbrand, Inc., warrants to the original consumer/purchaser against defects in material and/or workmanship from the date of the o.
デバイスHellenbrand Iron Curtain Systemの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hellenbrand Iron Curtain Systemをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHellenbrand Iron Curtain Systemの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hellenbrand Iron Curtain Systemの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hellenbrand Iron Curtain Systemで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hellenbrand Iron Curtain Systemを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHellenbrand Iron Curtain Systemの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hellenbrand Iron Curtain Systemに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHellenbrand Iron Curtain Systemデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。