HighpointメーカーRocketRAID 2522の使用説明書/サービス説明書
ページ先へ移動 of 90
RocketRAID 2522 SA T AII Host Adapter User’s Guide Revision: 1.0 Date: July 2007 HighPoint T echnologies, Inc..
Copyright Copyright © 2007 HighPoint T echnologies, Inc. This document contains materials protected by International Copyright Laws. All rights reserved. No part of this manual may be reproduced, transmitted or transcribed in any form and for any purpose without the express written permission of HighPoint T echnologies, Inc.
T able of Contents Chapter 1 Introduction 1 - About this Guide ................................................................................................... 1 - 1 2 - Introducing the RocketRAID 2522 Host Adapter .................................
T able of Contents Driver and Software CD ............................................................................................. 4 - 1 W indows Driver Installation ................................................................................
T ab le of Contents 3 - Array Management ............................................................................................... 7 - 3 4 - Device Manageme nt .....................................................................................
Chapter 1 Introduction Contents of this Chapter: About this guide Introducing the RocketRAID 2522 Host Adapter Understanding RAID Concepts and T erminology.
About this Guide The RocketRAID 2522 SA T AII Host Adapter’s User’s Guide provides information about the functions and capabilities of the host adapter, and instructions for installing, configuring and maintaining RAID arrays hosted by the adapter.
Introduction Physical Specifications: Size : 120.5mm X 84.7mm X 1.6mm EMI & ECC: FCC Part 15 Class B and CE Thermal and Atmospheric Characteristics: W orking T emperature Range : +5C ~+ 40C Relative Humidity Range : 20% ~ 80% non condensing Storage T emperature : -40C to 60C MTBF: 920,585 hours Electrical Characteristics: PCI-Express: 3.
Introduction Array initialization A redundant array (RAID5, RAID1, RAID10, RAID50) needs to be initialized to ensure full performance and reliability. Non-redundant arrays (RAID0, JBOD) do not need to be initialized.
Online RAID Level Migration This term describes the ability to change one type of array (RAID level), into a different type of array (changing a RAID 1 array into a RAID 10 array for example). Data is still accessible during the migration process, and a base level of security is still active.
Chapter 2 RocketRAID 2522 Hardware Description/Installation Contents of this Chapter: RocketRAID 2522 Hardware 1 - RocketRAID 2522 Adapter Layout 2 - LED Connections 3 - Installing the RocketRAID 2522.
RocketRAID 2522 Hardware Description/Installation RocketRAID 2522 Hardware 1 – RocketRAID 2522 Adapter Layout eSA T A Ports These represent the RocketRAID 2522’s two external Mini-SAS ports. Each Mini-SAS port host up to 4 SA T A or SA T A II hard disk.
RocketRAID 2522 Hardware Description/Installation J1-J4 LED Jumpers 2 - LED Connections The RocketRAID 2522 has 4 LED jumpers, set in banks of two. 2 Jumpers are provided for Disk Activity , and 2 are provided for Disk Failure. The numbered pins (1-4, 5-8) represent each of the channels (hard disks).
RocketRAID 2522 Hardware Description/Installation 3 - Installing the RocketRAID 2522 Host Adapter Note: Make sure the system is powered-off before installing the RocketRAID 2522 host adapter. The RocketRAID 2522 includes both standard and low-profile brackets.
RocketRAID 2522 Hardware Description/Installation After installing the adapter, attach hard disks or enclosure to the RocketRAID 2522 using the appropriate data cables.
Chapter 3 RocketRAID 2522 BIOS Utility Contents of this Chapter: RocketRAID 2522 BIOS Utility 1 - BIOS Command Overview 2 - Creating RAID Arrays 3 - Adding/Removing Spare Disks 4 - Updating the BIOS.
RocketRAID 2522 BIOS Utility The RocketRAID 2522’s BIOS Utility can be accessed using the “Ctrl+H” command. This command should be displayed automatically when the RocketRAID 2522’s BIOS screen appears during the system’s boot up procedure.
RocketRAID 2522 BIOS Utility Add/Remove Spare – this command is used to assign hard disks to function as spare disks. The controller is capable of using spare disks to automatically rebuild broken or faulted RAID arrays. Section 3 discusses this command in detail.
RocketRAID 2522 BIOS Uti lity Use the ← → arrow keys to select the Initialize command, and press ENTER. W arning: Initialization will destroy all pre- existing data on the selected hard disks. Use the ↑ ↓ arrow keys to highlight the target hard disk(s) and press ENTER.
RocketRAID 2522 BIOS Utility array, set as a spare disk, or partitioned to act as a single disk (by the operating system). 8 . T o complete the creation procedure, use the ↓ arrow key to highlight the Start Creation item and press ENTER. Press the Y (yes) key to create the array, or N (no) key to cancel the creation process.
RocketRAID 2522 BIOS Uti lity For Windows based operating systems: 1 ) Download the desired BIOS update from the Support section provided for the RocketRAID 2522 host adapter.
6 ) Select the RocketRAID 2522 from the drop down menu labeled “Controller”, and press the “Open” button – this will allow you to browse to the extracted BIOS download (step 1). 7 ) Highlight the image file, and click the “Flash!” button.
Chapter 4 RocketRAID 2522 Driver and Software Installation Microsoft Windows (2000, XP , 2003 Server , x64 and V ista) Contents of this Chapter: Driver and Software CD W indows Driver Installation.
RocketRAID 2522 Driver and Software Installation Driver and Software CD The RocketRAID 2522 retail box includes a Driver and Software CD. This CD can be used to generate driver diskettes, and install the RAID Management software for a variety of operating systems.
RocketRAID 2522 Driver and Software Installation 5 . Click on the “Please Select the Diskette you want to create” drop-down button, and select the appropriate OS from the list. 6 . Click on the “OK” button to create the driver diskette. T o install the RAID software: 1 .
RocketRAID 2522 Driver and Software Installation Windows Driver Installation Before installing the RocketRAID 2522 device driver, make sure the RocketRAID 2522 host adapter and all required hard disks have been installed into the system’s chassis (refer to the Hardware Installation section, page 2-2).
RocketRAID 2522 Driver and Software Installation 3 . Double click the “SCSI and RAID controllers” entry. If the RocketRAID 2522 device entry is not displayed, or there are “?” or “!” marks displayed near the RocketRAID 2522 entry, the driver has not been installed properly.
RocketRAID 2522 Driver and Software Installation Installing the RocketRAID 2522 driver for an existing Windows V ista system 1 . Install the RocketRAID 2522 host adapter into the PC, then boot up W indows V ista. 2 . Windows should automatically detect the card, and display the “Found New Hardware” wizard pop-up window.
RocketRAID 2522 Driver and Software Installation Logging On The RAID Management Console requires that a user (or Administrator) log on. The software is incapable of working with RAID arrays or hard disks attached to the RocketRAID 2522 until the user has logged on.
RocketRAID 2522 Driver and Software Installation Overview of Function-menus (tabs) File Remote Control - view information about remote systems System Configuration - switch between available remote sy.
RocketRAID 2522 Driver and Software Installation 3 - Creating an Array T o create an array: 1 . Highlight the “Management” menu, then select the “Array Management” function. 2 . Click the Create button on the toolbar or select the “Create” command from the “Operation” menu.
RocketRAID 2522 Driver and Software Installation Write-back - when the write-back setting is selected, all write requests sent to the array are cached.
RocketRAID 2522 Driver and Software Installation 2 . Highlight the array you want to delete, then click on the “Delete Icon” or select the Delete command from the “Operation” menu. 3 . A warning message will appear . Click Y es to delete the array .
RocketRAID 2522 Driver and Software Installation T o manually start the rebuild process for a broken/critical array: 1 . Highlight the “Management” menu, and select the “Array Management” function. 2 . Highlight the array that needs to be rebuilt.
RocketRAID 2522 Driver and Software Installation T o perform OCE/ORLM on an array: 1 . Highlight the “Management” menu, and select the “Array Management” function. 2 . Highlight the array you want to alter. 3 . Click the button on the toolbar or select “OCE/ORLM” command from the “Operation” menu.
RocketRAID 2522 Driver and Software Installation 8 - Misc. Array/Device Options Device Management The Device Management window provides configuration information about control- lers (the RocketRAID 2522 and other HighPoint host adapters), channels and hard disks.
RocketRAID 2522 Driver and Software Installation SAF-TE Management This feature allows the administrator to view and monitor a variety of SAF-TE related attributes, such as chassis temperature readings, disk failure, and the status of the chassis cooling apparatus (cooling fans).
RocketRAID 2522 Driver and Software Installation V iewing Logged Events T o view logged events: 1. Highlight the “V iew” menu, and select the “Event V iew” option. 2. In the Event V iew window , you can filer events, clear events, and save events to a file.
RocketRAID 2522 Driver and Software Installation 4 . The recipient will be listed in the main window . Y ou can use Modify or Delete button on the toolbar to modify or delete the recipient. T o test E-mail notification: 1. Highlight the “Management” menu, and select the “Event Notification” function.
RocketRAID 2522 Driver and Software Installation The T ask Schedule list displays all of the tasks assigned to the selected remote system. T o view detailed information about a specific task, highlight and Double-click the task’s name. Add a Scheduled T ask This command is used to add a Scheduled task for the selected remote system.
RocketRAID 2522 Driver and Software Installation Select the task type and the array that you want to verify or rebuild, then click “Next”. 1. Enter a name for the task. 2. Configure the frequency for the task. 3. Set the duration for the task. 4. Check the “Enable the task” option to activate this task.
RocketRAID 2522 Driver and Software Installation 1. Select a task from the T ask schedule list. 2. Click the “Delete” button on the toolbar. 10 - Configuring Remote Systems Then HighPoint RAID Man.
RocketRAID 2522 Driver and Software Installation 2 . Highlight the system you want to modify. 3. Click the Modify button on the toolbar or select the “Modify” command from the “Operation” menu. 4 . Enter new connection information in the popup window, and click OK to apply the changes.
RocketRAID 2522 Driver and Software Installation 2. Highlight the remote system you to establish a connection with. 3. Click the “Connect” button on the toolbar or select the “Connect” command from the “Operation” menu. 4. Enter the appropriate Login information in the popup window.
RocketRAID 2522 Driver and Software Installation 2. Highlight the remote system you want to modify. 3. Select the “System Configuration” option from the “Operation” menu. 4. Modify the information in the popup window. System Port - This is the TCP port number that the RAID Management Service uses to communicate with RAID Management Console.
RocketRAID 2522 Driver and Software Installation The user management window lists all users assigned to the selected remote system. The current/active user will be designated with an icon. Add a User This function adds a user account to the connected remote system.
RocketRAID 2522 Driver and Software Installation Delete a User This function deletes a user’s account on the connected remote system. T o delete a user: 1. Select the target user ID from the User list displayed in the User Management window. 2. Click Delete to remove the selected user .
3. In the popup window, assign the privileges for the selected user. 4. Click OK to apply your selections. RocketRAID 2522 Driver and Software Installation 4-25.
Chapter 5 Linux Driver Support Contents of this Chapter: Fedora Core 6 Linux installation Overview Red Hat Enterprise 5 Overview SuSE Linux Enterprise Server (SLES) installation Overview.
Linux Driver Support 1 - Fedora Core 6 Linux installation Overview This section provides instructions describing how to install and utilize the RocketRAID host adapter on a Fedora Core 6 Linux system.
Linux Drive r Support 3 ) When prompted “Do you have a driver disk?”, select “Y es”. At the “Insert your driver disk and press OK to continue. ” prompt, insert the driver diskette and then select “OK”. 4 ) The system will now load the RocketRAID driver automatically.
Linux Driver Support Use the command “mkdir xxxx ” to create a mount point for the RAID array. Then mount /dev/sda1 / xxxx in order to access it. Note: xxxx represents the desired name of the mount point. Step 3 Configure System to Automatically Load the Driver T o avoid typing in “insmod rr2522.
Linux Drive r Support 2 . If the original driver is installed in the /lib/modules/‘uname –r‘/kernel/drivers/ scsi/ directory, and loaded by the script file (Example /etc/init.d/hptdriver) during the init process, or the configure file (Example /etc/modules.
Linux Driver Support 1 - Red Hat Enterprise 5 Overview This section provides instructions describing how to install and utilize the RocketRAID host adapter on a Red Hat Enterprise 3 Linux system.
Linux Drive r Support When prompted “Where do you want to install the boot loader? ” in the “Boot Loader Configuration” dialog, select “Master Boot Record (MBR)” to instruct the system be to boot from the RocketRAID host adapter. Continue the installation as normal.
Linux Driver Support Step 2 Mounting and Partitioning the Device Example: A RAID array has been configured between several hard disks. This array will be registered to the system as device “/dev/sda”. T o create a partition on this array (which will listed as /dev/sda1), use the “fdisk / dev/sda” command.
Linux Drive r Support For example, add the following line to tell the system to mount /dev/sda1 to location / mnt/raid after startup: /dev/sda1 /mnt/raid ext2 defaults 0 0 4 - Updating the Driver If y.
Linux Driver Support 5 - Uninstalling the Driver T o uninstall the RocketRAID 2522 driver Note: The driver cannot be uninstalled while the system is booted from a disk or array attached to the RocketRAID host adapter. T o uninstall the driver, remove the lines added to /etc/fstab, and remove the files created in the /etc/init.
Linux Drive r Support 1 – SuSE Linux Enterprise Server (SLES) installation Overview This section provides instructions describing how to install and utilize the RocketRAID host adapter on a SuSE (SLES) Linux system.
Linux Driver Support 4 . When the “Diver Update Menu” is displayed, press “OK” and “back” for back to installer. 5 . Next. Select “back” to return to the installer. 6 . Installation will now proceed normally. Refer to SLES Linux documents for additional OS installation procedures.
Linux Drive r Support title Linux kernel (hd0,1)/vmlinux root=/dev/hda1 acpi=off initrd (hd0,1)/initrd Reboot the system to allow the new kernel parameters to take effect. Step 2 Install the Driver Module Extract the module file from the file /linux/suse /[arch]-[version]/install/update.
Linux Driver Support Use the command “mkdir xxxx ” to create a mount point for the RAID array. Then, mount /dev/sda1 / xxxx in order to access it. Note: xxxx represents the desired name of the mount point. Step 4 Configure System to Automatically Load the Driver T o avoid typing in “insmod rr2522.
Linux Drive r Support 4 - Updating the Driver T o update the driver , simply reinstall the driver following the steps in previous section, “ Install RocketRAID driver on an Existing System “.
Chapter 6 FreeBSD Driver Support Contents of this Chapter: 1 - Installing FreeBSD on the RocketRAID 2522 Controller 2 - Installing the RocketRAID 2522 Driver on an Existing System 3 - Updating the Dri.
1 - Installing FreeBSD on the RocketRAID 2522 Con- troller If you would like to install FreeBSD onto arrays attached to the RocketRAID host adapter, please follow the steps below.
FreeBSD Driver Support FreeBSD/i386 bootstrap loader, Revision 0.8 (mailto:jkh@narf.osd.bsdi.com, Sat Apr 21 08:46:19 GMT 2001) - Hit [Enter] to boot immediately, or any other key for command prompt. Booting [kernel] in 9 seconds… <-press SPACE key A prompted label “ ok ” will appear at the bottom of the screen.
FreeBSD Driver Support for FreeBSD 4.11-RELEASE ok load disk1:rr2522-4.1 1.ko for FreeBSD 5.0-RELEASE ok load disk0:rr2522-5.0.ko or FreeBSD 5.1-RELEASE ok load disk0:rr2522-5.1.ko for FreeBSD 5.2.1-RELEASE ok load disk0:rr2522-5.2.1.ko for FreeBSD 5.
FreeBSD Driver Support Note: On some systems, when ACPI is enabled, FreeBSD may not function pr operly . T ry disabling ACPI in the motherboar d’s BIOS settings, or type the command “ set hint.acpi.0.disabled=”1” ” under the boot prompt, in order to solve the problem.
FreeBSD Driver Support Alternately, it is possible extract the files from the .img files directly, without using a floppy diskette: For FreeBSD 4.x: # vnconfig vn0c freebsd_xxx.img # mount /dev/vn0c /mnt # cp /mnt/rr2522-xxx.ko /modules/rr2522.ko # vnconfig –du vn0c myfilesystem mount=/mnt For FreeBSD 5.
FreeBSD Driver Support Loading /boot/defaults/loader.conf /kernel text=0x24f1db data=0x3007ec+0x2062c - <- For FreeBSD 5.1 and later: select “6” on “Welcome to FreeBSD” screen. Hit [Enter] to boot immediately, or any other key for command prompt.
FreeBSD Driver Support Step 4 Configure the System to Mount V olumes at Star tup Instruct the system to automatically mount the array by modifying the file /etc/fstab.
Chapter 7 Mac OSX Driver and RAID Management Software Contents of this Chapter: 1 - Installing the driver and RAID utility 2 - Preparing Hard disks 3 - Array Management 4 - Device Management 5 - Confi.
1 Installing the driver and RAID utility Installing the package 1 ) Double click the package labeled “ rr2522-mac-v10-070407.dmg ” to start the installation process (“xxx” refers to the revision of the driver) . This will open the driver and software packag.
Mac OSX Driver and RAID Management Software Y ou will then be notified that a reboot is needed to install the software. Click “ Continue Installation ”.
Mac OSX Driver and RAID Management Software 1 ) Locate and double click the “uninstall.command” file. 2 ) This will initiate the uninstall script, and will open a T erminal window .
Mac OSX Driver and RAID Management Software 3 ) Choose the array type you want to create from the drop-down list. 4 ) Enter a name for the array (this is optional) 5 ) If you are creating a redundant RAID array (RAID1, 5, 10 , 50 ), select an initialization option for the array.
Mac OSX Driver and RAID Management Software 9 ) Click Create . If you have specified an initialization option, the initialization process will start automatically. Deleting an Array T o delete an array: 1 ) Select “ Manage - Array ” from the menu.
Mac OSX Driver and RAID Management Software Note: If the system utilizes hot-swap capable enclosures, you can add new physical disks to the RocketRAID card in order to rebuild or modify an existing array, using the “ Rescan ” feature.
Mac OSX Driver and RAID Management Software Click the Maintenance button. Select the target array type. Click the OCE/ORLM button. The OCE/ORLM page will appear.
Mac OSX Driver and RAID Management Software 4 Device Management Select the “Manage - Device” function to access the device management page. Change Device Settings Depending upon the capabilities RAID controller and hard disks drives in use, several configurable device settings may be available: Read Ahead, W rite Cache, TCQ, and NCQ.
Mac OSX Driver and RAID Management Software SHI – Storage Health Inspector The SHI interface displays a brief “health” summary of each hard disk.
Mac OSX Driver and RAID Management Software S.M.A.R.T Status Y ou can view S.M.A.R.T . (Self-Monitoring, Analysis, and Reporting T echnology) data about a particular hard disk to help troubleshoot problems that occur . Y ou can also setup periodically S.
Mac OSX Driver and RAID Management Software Adding a Spare Disk T o add a spare disk, select a disk from the A vailable Disks list and click Add Spare button.
Mac OSX Driver and RAID Management Software Removing a Spare Disk T o remove a spare disk, select it from the Spar e Pool list and click the Remove Spar e button.
Mac OSX Driver and RAID Management Software Scheduling a T ask T o add a task schedule: Select the array that you want to verify or rebuild. Enter a name for the task. Configure the frequency for the task. Check the Submit button. Delete a Scheduled T ask T o delete a task schedule: Select a task from the T asks List.
Mac OSX Driver and RAID Management Software Enable Audible Alarm This setting enables and disables the RocketRAID host adapter’s alarm. Listening Port Change Listening Port This is the TCP port numb.
Mac OSX Driver and RAID Management Software in order to communicate with the management console and web browser software. When you connect to the service, the port value you enter must be in accordance with the system port value on the service. The default value is 7402.
Appendix Customer Support.
Customer Support If you encounter any problems while utilizing the RocketRAID 2522, or have any questions about this or any other HighPoint product, feel free to contact our Cus- tomer Support Department.
FCC Part 15 Class B Radio Frequency Interference statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
デバイスHighpoint RocketRAID 2522の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Highpoint RocketRAID 2522をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHighpoint RocketRAID 2522の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Highpoint RocketRAID 2522の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Highpoint RocketRAID 2522で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Highpoint RocketRAID 2522を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHighpoint RocketRAID 2522の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Highpoint RocketRAID 2522に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHighpoint RocketRAID 2522デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。