DELI CASES MODEL: OSAA HAND B O O K INST ALLA TION & OPERA TION 9/03 P061773M.
.
Welcome to the ORIGIN 2 display case family . We’r e very pleased you joined us. This installation and operation handbook has been especially prepar ed for everyone involved with ORIGIN 2 display cases – owners, managers, installers and maintenance personnel.
.
1 T ABLE OF CONTENTS GENERAL INFORMA TION – P AGES 2 - 4 General information, first step recommendations and case dimensional drawings. THE USE OF CASTERS – P AGE 5 Cases roll on casters–general use and castor r emoval. LINE-UP – P AGES 6 - 7 A ten step procedur e for initial case lineup with illustrations.
GENERAL INFORMA TION DESCRIPTION OF CASES : The refrigerated display cases described in this handbook are part of the Hill PHOENIX , Origin 2 design series.
3 54 15/16 in [139.5 cm] 33 1/4 in [84.5 cm] 11 1/2 in [29.2 cm] 1 3/16 in [3.0 cm] 5 13/16 in [14.7 cm] FLA T REAR SILL (OPTIONAL) REAR SLIDING DOORS 21 1/2 in [54.6 cm] 28 3/8 in [72.0 cm]* 35 11/16 in [90.7 cm] 38 5/16 in [97.3 cm] 49 1/16 in [124.
31 11/16" 71 1/4" 4" 6' CASE FRONT OF CASE 4 GENERAL INFORMA TION BASEHORSE LOCA TIONS FOR MODEL OSAA.
5 34 12 CASES MOVE ON CASTERS FOR EASIER INST ALLA TION CASTERS MA Y BE DISCARDED. ROLL OUT OF TRUCK . When there is a truck - level delivery dock, cases may be rolled dir ectly from the truck to the store floor .
6 LINE UP 1 5 Consult With General Contractor Ask the general contractor if there have been changes in the building dimensions since the print you are using was issued. Also, ask the points of refer ence from which you should take dimensions to locate the cases.
10 Bolt Cases T ogether Using Bolt Holes Provided Push cases tightly together . Bolt cases together through the five holes provided in the “C” frame and pipe chase as shown in illustration. Tighten until all margins are equal; do not over tighten.
8 Install plenum covers under deck pans. The plenum covers are shipped loose in the case and are installed between the lower rear baf fle and the fan plenum. 6 Seal joints along pipe chase seam with the caulk provided. Now that cases have been positioned and leveled, you may proceed to trim-out case lineup.
9 9 Close joints of front panel. The panel is slotted on the bottom to allow left or right adjustment as requir ed. 10 Install curved front panel joint (if cases come equipped with curved front pan- els). Curved panel joints are shipped loose in the case and are attached with the screws pr ovided.
REFRIGERA TION COMPONENTS Refrigeration components for the OSAA-6’ are easily accessible in the tank and underneath the case. The expansion valve and suction line 1/4” access valve are both located in the left hand front side of the tank and are accessible without lifting the fan plenum.
11 Access V alve - Access port on the evaporator that allows service personnel to check system pr essure. Accumulator - A device installed on the suction line that is used to boil off small amounts of liquid r efrig- erant so liquid does not reach the compr essor .
12 PLUMBING The drain outlet is located front and center of the cases for convenient access and is specially molded out of ABS material. The “P” trap, furnished with the case, is constructed of schedule 40 PVC pipe. Care should be given to assure that all connec- tions are water tight and sealed with the appropriate PVC or ABS cement.
13 ELECTRICAL HOOKUP DEFROST HEA TERS, 208/240 VOL TS L1 L2 RED BLUE EV APORA TOR F ANS, 120 VOL T WIRE NUMBER COMPONENT COLOR CODING BLACK TEMPERA TURE CONTROL, 120 VOL T LIGHTS, 120 VOL T DEFROST TE.
14 CONTROL SETTINGS- MODEL OSAA-6’ Manual Defr ost Button Enter Button Up Button Down Button Fan Status LED Compressor Status LED Defrost Status LED Factory Settings Parameter Description OSAA-6’ .
15 Error Code System Status F2 Indicates an open or shorted evaporator sensor . Corr ect problem to r eset control. } } } F1 Indicates an open or shorted temperature sensor . Cycle Power to reset contr ol. A2 Digital input is closed and digital input option (if) 1 is selected.
HTR1 FAN MOTOR J3 P3 FAN MOTOR M1 M2 HTR2 SHELF LIGHTS (OPTIONAL) DEF. TERM. CONTROL (OPTIONAL) TEMP. CONTROL (OPTIONAL) FRONT GLASS ANTI-COND HEATER DEFROST HEATERS (OPTIONAL) 13 12 11 21 23 20 14 19.
17 CASE OPERA TION American Style Self-Contained Curved Glass Service Deli Mer chandiser OSAA - 6’ All measurements are taken per CRMA specifications. Medium T emperature Defrost Schedule No. Per Day Hours 1 12 midnight 2 12 am - 12 pm 3 6 am - 2 pm - 10 pm 4 12 - 6 am - 12 - 6 pm 4 NOTE: - - - not an option on this case model.
18 DEFROST AND TEMP CONTROL • Electric defrost termination contr ol sensor bulb location • Electric defrost termination pr obe location • T emperature contr ol sensor bulb location (OSA) It is important to consult the control setting guidelines shown on page 17 before setting defrost times.
4 2 3 1 19 AIR FLOW AND PRODUCT LOADING Cases have been designed to provide maxi- mum product capacity within the r efrigerated air envelope. It is important that you do not overload the food product display so that it impinges on the air flow pattern.
20 USE AND MAINTENANCE CASE CLEANING Case is designed to facilitate cleaning. There is a wide radius formed on the front and back of the inside bottom that helps accelerate liquid flow and eliminates difficult-to- clean sharp corners.
21 F ANS The evaporator fans are equipped with 5 watt fan motors, 1550 RPM’ s. The motor has a counter clockwise rotation when viewed fr om the shaft end. The fan blades are 6” in diameter and the blades ar e pitched according to the charts below .
E10 E11 E09 23 11 24 9 1 26 2 17 88 87 22 5 28 20 3 48 53 55 56 46 9a 69 21 29 36 42 49 E01 77 81 82 66 P AR TS ORDERING MODEL OSAA 22 50 E06 E07 E09 E11 E10 E20.
23 Location Part Descriptions Number 1 Kickplate , Storm Grey 2 Master Bumper , Featherstone, Smoke, White, French V anilla, Black 3 Lower Front Panel , Painted or Stainless 5 Front Glass, Lift-Up The.
24 P AR TS ORDERING Procedure 1. Contact the Service Parts Department Hill PHOENIX 1925 Ruf fin Mill Road Colonial Heights, Virginia 23834 T el: 800-283-1109 Fax: 804-526-3897 2. Pr ovide the following information about the part you are or dering: • Model number and serial number of the case on which the part is used.
25 NOTES.
26 NOTES.
6/00 W ARRANTY HEREINAFTER REFERRED TO AS MANUF ACTURER FOURTEEN MONTH W ARRANTY . MANUF ACTURER’S PRODUCT IS WARRANTED TO BE FREE FROM DEFECTS IN MA TERIAL AND WORKMANSHIP UNDER NORMAL USE AND MAINTENANCE FOR A PERIOD OF FOURTEEN MONTHS FROM THE DA TE OF ORIGINAL SHIPMENT .
1925 Ruffin Mill Road, Colonial Heights, V A 23834 Due to our commitment to continuous improvement all specifications are subject to change without notice. Hill PHOENIX is a Sustaining Member of the American Society of Quality . CRMA endorsed Visit our web site at www .
デバイスHill Phoenix OSAAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hill Phoenix OSAAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHill Phoenix OSAAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hill Phoenix OSAAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hill Phoenix OSAAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hill Phoenix OSAAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHill Phoenix OSAAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hill Phoenix OSAAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHill Phoenix OSAAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。