Hisense Corporation INST ALLA TION INST ALLA TION INSTR UCTION INSTR UCTION MANU AL MANU AL SPLIT TYPE AIR CONDITIONER SPLIT TYPE AIR CONDITIONER KFR-3208GW/AE KFR-3208GW/AE.
Compact Size This model is smaller than its predecessors and yet offers the same capabilities. Microprocessor Controlled Operation The interior compartment of the remote control unit contains several features to facilitate automatic operation, clearly displayed for easy use.
Contents 1 Page Alert symbol Caution statements Composition of the air conditioner Operation guide Care and cleaning Tips for energy saving Troubleshooting Schematic diagram Pardon not to inform you if the contents of the manual changes.
Caution Statements WARNING WARNING WARNING CAUTION 2 1.Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button. 2.Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.
Refrigerant tubes OUTDOOR UNIT Air outlet Composition of the Air Conditioner 3 1.Diagram of Structure This air conditioner consists of an indoor unit and an outdoor unit.
4 2.Introduction of the Indoor ControI Unit INDOOR UNIT OPERATING lamp TIMER lamp POWER lamp POWER TIMER OPERATING HIGH POWER lamp REMOTE CONTROL receiver ON/OFF button IMPORTANT : Avoid using radio equipment such as mobile phone near (within 1m) the indoor unit.
Symbols 3.Introduction of Display (1) Operation mode AUTO COOL HEAT MILD DRY FAN (2) Fan speed Automatic operation HIGH MEDIUM LOW (4) Timer 12-hour ON Timer 12-hour OFF Timer 1-hour OFF Timer (5) NIG.
4.Introduction of the Remote control Unit NOTE The illustration above pictures the remote control unit after the cover has been lowered and removed. When you press the buttons on the remote control unit,the mark appears in the display to transmit the setting changes to the receiver in the air conditioner.
:The air conditioner starts at the set time. The air conditioner stops at the set time. or :The air conditioner makes the room warm. :The air conditioner reduces the humidity in the room. direction to one of the six possible positions manually, or to select the The airflow direction can be set manually.
Operation Guide 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction m arked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button.
Operation with the Remote Control Unit(continued) NOTE Check that the circuit breaker on the power panel is turned on and that the operation selector of the indoor unit is in the ON position. If the automatic operation settings of the unit do not meet your needs, press the setting buttons as described below and change the settings as desired.
Adjusting the Airflow Direction The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right. 2. Vertical 1. Horizontal ! CAUTION When the humidity is high, the vertical vanes should be in the front position during the cooling or dehumidifying operation.
Night Setback / Simultaneous Use Energy Saving ¡ñ Night Setback Mode Night Setback Mode is used for saving energy. Press the SLEEP button in operation. The mark appears in the display. T o release the night setback function, press the SLEEPbutton again.
Using the 12-Hour ON and OFF Timer After the length of time set for TIMER ON elapses, the unit begins operating. The display depicted at left indicates that the air conditioner will begin operating in three hours. Setting Procedures: STEP 1 Press the MODE button and set the desired operation mode and press the ON/OFF operation button.
Using the 1-Hour OFF Timer 13 This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. The indicator in the display indicates that this function is operating. Setting procedure: Regardless of whether the unit is operating or stopped, press the 1 HR .
14 Special Remarks Heating ( ) Operation Heating performance Defrosting POWER lamp Because this air conditioner heats a room by drawing on the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low.
Operation without the Remote Control Unit Care and Cleaning NOTE If you have lost the remote control unit or it has trouble, follow the steps below. 1.When the air conditioner is not running If you want to turn on the air conditioner, pressing the ON/OFF button once.
Care and Cleaning (continued) Anti-Mold Filter How to remove the anti-mold filter The anti-mode filter behind the air intake grille should be checked and cleaned at least once every three weeks. 1.Grasp both ends of the air intake grille and pull it out and up.
Tips for Energy Saving Do not Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged. Let sunlight directly into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer time to cool the room.
Schematic Diagram 1. Refrigerant Flow Diagram 18 Indoor unit Heat exchanger Heat exchanger Wide tube Narrow tube Outdoor unit Wide service valve Accumulator Compressor 4-way valve Capillary Narrow service tube Cooling cycle Heating cycle Capillary Check valve 2.
Appendix: Installation This operation manual has explicit information for installation and maintenance in most conditions. Contact the local distributor or after-sales service for further information. A. Wiring Only qualified professionals should carry out wiring of the appliance.
2. Location 8 2-1 Indoor unit 2-2 Outdoor unit WARNING: Maintain the required space around the appliance to prevent overheat. The area for installation of the appliance should not be in an area with t.
3. Installation of the indoor unit 21 Appendix: Installation Remove the wall plate (1)Remove the fixing screws and keep them for future use (not used during installation). (2)Press the two triangular signs on the outer shell and remove the fixing clip.
22 Appendix: Installation (3)Any part of the drainpipe should be below the outlet of the indoor unit and the joints should be wrapped with waterproof adhesive tape to prevent leakage of condensed water. (4)Bind the tubes, wires and the drainpipe tightly with binding tape, with the drainpipe under the wires.
CAUTION 23 Appendix: Installation 5.Air purging Air and moisture remaining in the refrigerant system have undesirable effects as indicated below. Therefore, they must be purged completely.
P ACKING LIST NO. NAME AMOUNT 1. 2. 3. 4. 5. 6. 7. 8. 9. OUTDOOR UNIT POWER CABLE DRAINAGE ELBOW * AIR FRESH FIL TER INDOOR UNIT MANUAL REMOTE CONTROL UNIT BA TTERY NAIL SPECIAL 1 1 1 1 1 1 1 2 6 THE SYMBOL "*" ST ANDS FOR THE P ART TO BE PICKED AND MADE PURCHASE.
デバイスHisense Group KFR-3208GWの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hisense Group KFR-3208GWをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHisense Group KFR-3208GWの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hisense Group KFR-3208GWの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hisense Group KFR-3208GWで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hisense Group KFR-3208GWを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHisense Group KFR-3208GWの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hisense Group KFR-3208GWに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHisense Group KFR-3208GWデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。