Processes OM-925 217 694A February 2004 H a n d l e r 1 4 0 / 1 8 0 And H-10 Gun Arc W elding Power Source And Wire Feeder Description MIG (GMAW ) W elding Flux Cored (FCA W ) W elding Visit our website at www.
Hobart W elders manufactures a full line of welders and welding related equipment. For information on other quality Hobart products, contact your local Hobart distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-877-Hobart1.
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T ABLE OF CONTENTS SECTION 8 − MIG WELDING (GMA W) GUIDELINES 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1. T ypical MIG Process Connections 31 . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-925 Page 1 Return T o T able Of Contents SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _8/03 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
OM-925 Page 2 Return T o T able Of Contents Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin.
OM-925 Page 3 Return T o T able Of Contents 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces.
OM-925 Page 4 Return T o T able Of Contents 1-5. Principal Safety Standards Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from American W elding Society , 550 N.W . LeJeune Rd, Miami FL 33126 (phone: 305-443-9353, website: www .
OM-925 Page 5 Revenez à la table des matières SECTION 2 − CONSIGNES DE SÉCURITÉ − À LIRE A V ANT UTILISA TION som_fre 8/03 2-1. Signification des symboles Signifie « Mise en garde. Faire preuve de vigilance. » Cette procédure présente des risques identifiés par les symboles adjacents aux directives.
OM-925 Page 6 Revenez à la table des matières Le rayonnement de l’arc génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) suscep- tibles de causer des brûlures oculaires et cutanées. Des étincelles sont projetées pendant le soudage.
OM-925 Page 7 Revenez à la table des matières 2-3. Autres symboles relatifs à l’installation, au fonctionnement et à l’entretien de l’appareil. Risque D’INCENDIE OU D’EXPLO- SION D Ne pas placer l’appareil sur une surface inflam- mable, ni au−dessus ou à proximité d’elle.
OM-925 Page 8 Revenez à la table des matières 2-4. Principales normes de sécurité Safety in W elding, Cutting, and Allied Processes, norme ANSI Z49.1, de l’American W elding Society , 550 N. W . LeJeune Rd, Miami FL 33126 (téléphone : (305) 443−9353, site Web : www .
OM-925 Page 9 Return T o T able Of Contents SECTION 3 − SPECIFICA TIONS 3-1. Specifications A. 1 15 V AC Model Rated Welding Output Amperage Range Maximum Open- Circuit V oltage DC Amperes Input at .
OM-925 Page 10 Return T o T able Of Contents 3-2. Duty Cycle And Overheating Duty Cycle is percentage of 10 minutes that unit can weld at rated load without overheating. If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. W ait fifteen minutes for unit to cool.
OM-925 Page 1 1 Return T o T able Of Contents 3-3. V olt-Ampere Curves The volt-ampere curves show the minimum and maximum voltage an d amperage output capabilities of the welding power source. Curves of other settings fall between the curves shown. ssb1.
OM-925 Page 12 Return T o T able Of Contents SECTION 4 − INST ALLA TION 4-1. Installing Welding Gun 803 71 1-A 1 Drive Assembly 2 Gun Securing Thumbscrew 3 Gun End Loosen thumbscrew . Insert end through opening until it bottoms against drive assembly .
OM-925 Page 13 Return T o T able Of Contents 4-3. Process/Polarity T able Process Polarity Cable Connections Process Polarity Cable T o Gun Cable T o Work GMAW − Solid wire with shield- ing gas DCEP.
OM-925 Page 14 Return T o T able Of Contents 4-5. Installing Gas Supply Obtain gas cylinder and chain to running gear , wall, or other stationary support so cylinder cannot fall and break of f valve. 1 Cap 2 Cylinder V alve Remove c ap, stand to side of valve, and open valve slightly .
OM-925 Page 15 Return T o T able Of Contents 4-6. Selecting A Location And Connecting Input Power For 1 15 V AC Model 1 Rating Label 2 Grounded Receptacle A 1 15 volt, 20 ampere individual branch circuit protected by time-delay fuses or circuit breaker is required.
OM-925 Page 16 Return T o T able Of Contents 4-7. Selecting A Location And Connecting Input Power For 230 V AC Model 1 Rating Label Supply correct input power . 2 Plug (NEMA 6-50P) 3 Receptacle (NEMA 6-50R) Connect plug to receptacle. 4 Line Disconnect Device See Section 4-8.
OM-925 Page 17 Return T o T able Of Contents 4-8. Electrical Service Guide For 230 V AC Model Input V oltage 230 Input Amperes At Rated Output 20 Max Recommended Standard Fuse Or Circuit Breaker Ratin.
OM-925 Page 18 Return T o T able Of Contents 4-10. Threading Welding Wire 1 Wire Spool 2 Welding Wire 3 Inlet Wire Guide 4 Pressure Adjustment Knob 5 Drive Roll 6 Gun Conduit Cable Lay gun cable out straight. T ools Needed: Pull and hold wire; cut off end.
OM-925 Page 19 Return T o T able Of Contents SECTION 5 − O P E R A T I O N 5-1. Controls 1 Wire Speed Control Us e control to select a wire feed speed. As V oltage switch setting increases, wire speed range also increases (see weld setting label in welding power source or Sections 5-2 or 5-3 , as applicable).
OM-925 Page 20 Return T o T able Of Contents 5-2. W eld Parameter Chart For 1 15 V AC Model W elding Guide for 1 15 V olt Settings are approximate. Adjust as required. Thicker materials can be welded using proper technique, joint preparation and multiple passes.
OM-925 Page 21 Return T o T able Of Contents 217 618-A Wire W elding Package Recommended V oltage and Wire Speed Settings for thickness of metal being welded. CHANGING POLARITY DCEN 20 ga. 18 ga. 16 ga. 1 1 ga. Number left of slash is V oltage Setting / Number right of slash is Wire Feed Setting.
OM-925 Page 22 Return T o T able Of Contents 5-3. W eld Parameter Chart For 230 V AC Model Welding Guide for 230 Volt Settings are approximate. Adjust as required. Thicker materials can be welded using proper technique, joint preparation and multiple passes.
OM-925 Page 23 Return T o T able Of Contents 217 754- Wire W elding Package Recommended V oltage and Wire Speed Settings for thickness of metal being welded. CHANGING POLARITY DCEN 18 ga. 16 ga. 1 1 ga. Number left of slash is V oltage Setting / Number right of slash is Wire Feed Setting.
OM-925 Page 24 Return T o T able Of Contents SECTION 6 − MAINTENANCE &TROUBLESHOOTING 6-1. Routine Maintenance Y Disconnect power before maintaining. 3 Months Replace unreadable labels. Repair or replace cracked weld cable. Clean and tighten weld terminals.
OM-925 Page 25 Return T o T able Of Contents 6-4. Changing Drive Roll Or Wire Inlet Guide 1 Inlet Wire G u i d e S e c u r i n g Screw 2 Inlet Wire Guide Loosen screw . Slide tip as close to drive rolls as possible without touching. T ighten screw . 3 Drive Roll The drive roll consists of two dif fer- ent sized grooves.
OM-925 Page 26 Return T o T able Of Contents 6-6. Cleaning Or Replacing Gun Liner Ref. 802 446 8 mm / 10mm Y Disconnect gun from unit. T ools Needed: T o Reassemble Gun: Insert new liner . Install wire outlet guide so that 1/8 in (3 mm) of liner sticks out.
OM-925 Page 27 Return T o T able Of Contents 6-7. Replacing Switch And/Or Head T ube Ref. ST-800 795-C T ools Ne e d e d : 19 mm Remove handle locking nut. Slide handle. Secure head tube in vice. Loosen jam nut. Remove from vice an d turn head tube out by hand.
OM-925 Page 28 Return T o T able Of Contents 6-8. T roubleshooting T able T rouble Remedy No weld output; wire does not feed; fan does not run. Secure power cord plug in receptacle (see Section 4-6). does not run. Replace building line fuse or reset circuit breaker if open.
OM-925 Page 29 Return T o T able Of Contents SECTION 7 − ELECTRICAL DIAGRAM 217 621-A Figure 7-1. Circuit Diagram For 1 15 V AC Model.
OM-925 Page 30 Return T o T able Of Contents 217 755-A Figure 7-2. Circuit Diagram For 230 V AC Model.
OM-925 Page 31 Return T o T able Of Contents SECTION 8 − MIG WELDING (GMA W) GUIDELINES 8-1. T ypical MIG Process Connections Y W eld current can damage electronic parts in vehicles. Disconnect both battery cables before welding on a vehicle. Pla c e w o r k c l a m p a s close t o the weld as possible.
OM-925 Page 32 Return T o T able Of Contents 8-2. T ypical MIG Process Control Settings These settings are guidelines only . Material and wire type, joint design, fitup, position, shielding gas, etc. affect settings. T est welds to be sure they comply to specifications.
OM-925 Page 33 Return T o T able Of Contents 8-3. Holding And Positioning Welding Gun Welding wire is energized when gun trigger is pressed. Before lowering helmet and pressing trigger , be sure wire is no more than 1/2 in (13 mm) past end of nozzle, and tip of wire is positioned correctly on seam.
OM-925 Page 34 Return T o T able Of Contents 8-4. Conditions That Affect Weld Bead Shape Weld bead shape depends on gun angle, direction of travel, electrode extension (stickout), travel speed, thickness of base metal, wire feed speed (weld current), and voltage.
OM-925 Page 35 Return T o T able Of Contents 8-5. Gun Movement During Welding Normally , a single stringer bead is satisfactory for most narrow groove weld joints; however , for wide groove weld joints or bridging across gaps, a weave bead or multiple stringer beads works better .
OM-925 Page 36 Return T o T able Of Contents 8-8. T roubleshooting − Excessive Spatter Excessive Spa tter − scattering of molten metal partic les that cool t o solid form near weld bead. S-0636 Possible Causes Corrective Actions Wire feed speed too high.
OM-925 Page 37 Return T o T able Of Contents 8-1 1. T roubleshooting − Lack Of Penetration Lack Of Penetration − shallow fusion between weld metal and base metal. Lack of Penetration Good Penetration S-0638 Possible Causes Corrective Actions Improper joint preparation.
OM-925 Page 38 Return T o T able Of Contents 8-14. T roubleshooting − W aviness Of Bead W aviness O f Bead − weld metal that is not parallel and does not cover joint formed by base metal. S-0641 Possible Causes Corrective Actions W elding wire extends too far out of nozzle.
OM-925 Page 39 Return T o T able Of Contents 8-16. Common MIG Shielding Gases This is a general chart for common gases and where they are used. Many different combinations (mixtures) of shielding gases have been developed over the years. The most commonly used shielding gases are listed in the following table.
OM-925 Page 40 Return T o T able Of Contents Problem Remedy Probable Cause W elding arc not stable. Wire slipping in drive rolls. Adjust pressure setting on wire feed rolls. Replace worn drive rolls if necessary . W rong size gun liner or contact tip.
OM-925 Page 41 Return T o T able Of Contents Notes.
OM-925 Page 42 Return T o T able Of Contents SECTION 9 − P ARTS LIST . Hardware is common and not available unless listed. 803 716-A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 34 32 31 49 43 48 47 46 45 44 51 50 36 35 42 41 40 38 39 37 30 33 52 Figure 9-1.
OM-925 Page 43 Return T o T able Of Contents Description Part No. Dia. Mkgs. Item No. Figure 9-1. Main Assembly Quanti ty 1 199 566 DOOR, access 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-925 Page 44 Return T o T able Of Contents Description Part No. Dia. Mkgs. Item No. Figure 9-1. Main Assembly (Continued) Quanti ty 40 196 574 SWITCH, rocker DPST (230 V AC model) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-925 Page 45 Return T o T able Of Contents Quanti ty Description Part No. 195 957 Item No. Figure 9-2. H-10 Gun 1 169 715 NOZZLE, slip type .500 orf flush 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes.
Warranty Questions? Call 1-877-HOBART1 for your local Hobart distributor. hobart retail 8/03 Service Y o u always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor or call 1-800-332-3281.
PRINTED IN USA 2003 Hobart Welding Products. 1/03 Hoba rt We lding Product s An I l li noi s T ool Works Company 600 W es t Main Street Troy , OH 45373 U SA For T echn i cal A ssistance: Call1-800.
デバイスHobart Welding Products OM-925 217 694Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hobart Welding Products OM-925 217 694Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHobart Welding Products OM-925 217 694Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hobart Welding Products OM-925 217 694Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hobart Welding Products OM-925 217 694Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hobart Welding Products OM-925 217 694Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHobart Welding Products OM-925 217 694Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hobart Welding Products OM-925 217 694Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHobart Welding Products OM-925 217 694Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。