July 2007 © 2007 Honeywe ll. All rights reserved. 800-00005 PW -6000 Intellig ent Contr oller Installation and Configuration Guide P ar t Number: PW6K1IC.
Copyright© 2007 Honeywell. All right s reserved. All product and brand names are the service ma rks, trademarks, registe red trademarks, or registered service marks of their respec tive owners. Printed in the United S tates of America. Honeywell reserves th e right to change an y inform ation in this document at any time without prior notice.
.
PW -6000 In stallation and Configurati on Guide , Docume nt 800-00005, Revision A iii C ONTENT S Notices........................ .................. .................. .................................... ................... 1 Warnings and Cautions ...
PW -6000 In stallation and Configurati on Guide , Docume nt 800-00005, Revision A v L IST OF F IGURES Figure 1: PW-6000 Conn ections, LEDs, and DIP Sw itches .............................. 7 Figure 2: PW-6000 Power Terminals ..........................
PW -6000 In stallation and Configurati on Guide , Docume nt 800-00005, Revision A vii L IST OF T ABLES Table 1 PW-6000 Jumper Settings ....................... ......................................... .. 8 Table 2 PW-6000 DIP Switch Settings ........ .
viii www.honeywell.com.
PW -6000 Installa tion Guide , D ocument 800-00005, Revision A 1 PW -6000 Installation 1 Notices 1.1 W arnings and Cautions Before Inst allation Wa r n i n g: Before installation, TURN OFF the external circuit breaker which supplies power to the system.
2 www .honeyw ell.com PW-6000 Installation Notices Earth Grounding Wa r n i n g: EAR TH ground all enclosures for pr oper installation. Use Suppressors Wa r n i n g: Use suppressors on all door strikes. Use S-4 suppressors for installation. Honeywell Integrated Security , Inc.
PW-6000 Installation Notices PW -6000 Installa tion Guide , D ocument 800-00005, Revision A 3 1.4 Disclaimer – Product Liab ility; Mutual Indemnification If a Customer receives a claim that a Produc.
4 www .honeyw ell.com PW-6000 Installation Notices Show the RMA number on all packages ship ped. Packages, which are not marked with an RMA number will be refused at the factory and returned to you COD. Carefully pack the equipmen t for shipment. Use the original packing material whenever pos sible 1.
PW-6000 Installation Product Overview PW -6000 Installa tion Guide , D ocument 800-00005, Revision A 5 Customer shall not copy the des ign of any of the Produc ts or use or cause to be used any Product design or related materials for its own b enefit or for the benefit of any other party .
6 www .honeyw ell.com PW-6000 Installation Product Overview 2.3 Other • An on-board real time clock maintains th e date and time, taking into account leap year and accounting for global time zones and daylight savings time changes. • The database for the system configur ation and card holders are stor ed in FLASH memory .
PW-6000 Installation Product Overview PW -6000 Installa tion Guide , D ocument 800-00005, Revi sion A 7 Figur e 1: PW -6000 Connections, LEDs, and DIP Switches.
8 www .honeyw ell.com PW-6000 Installation Setting Up the PW -6000 Hardware 3 Setting Up the PW -6000 Hard ware The PW -6000 processor is configured with 12 jumpers and a set of 4 DIP switches. These jumpers/switches set up the port in terface, end of line termination, and operating mode configuration.
PW-6000 Installation Setting Up the PW-6000 Hardware PW -6000 Installa tion Guide , D ocument 800-00005, Revision A 9 3.2 Setting the DIP Switches Dual In-line Package (DIP) switc hes are re ad when the system powers up, except where noted otherwise. The followi ng table shows the setting opti ons.
10 www .honeyw ell.com PW-6000 Installation Setting Up the PW -6000 Hardware The PW -6000 DIP switches need to be set twice: 1. Configure the S4-S3-S2-S1 DIP switches to off-off-on-off to set the default TCP/IP address to 192.168.0.251. 2. Apply power to the panel to set the IP address.
PW-6000 Installation Setting Up the PW-6000 Hardware PW -6000 Installa tion Guide , D ocument 800-00005, Revision A 11 3.3 T echnical Specifications T able 3 PW -6000 T echnical Specifications Category Description W ARNING: PW -6000 is manufactured for use in low-voltage, Class 2 circuits only .
12 www .honeyw ell.com PW-6000 Installation Setting Up the PW -6000 Hardware Caution: Locate the power source as close to this boar d as possible. Connect power with minimum of 18A WG wires.
PW-6000 Installation Setting Up the PW -6000 Hardware PW -6000 Installa tion Guide , D ocument 800-00005, Revi sion A 13 Run TimeSupplying Power to the PW -6000 Interface 3.5 Supplying Power to the PW -6000 Interface The processor accepts 12Vdc for power .
14 www .honeyw ell.com PW-6000 Installation Setting Up the PW -6000 Hardware 3.6 Communications Wiring The PW -6000 proce ssor communicates to the host vi a on-board Ethernet 10Base-T/100Base-TX port or on port 1. Port 1 may be configured as RS-232, two-wire RS-485 or option al Lantronix Ethernet 10Base-T/ 100Base-TX CoBox-Micro interface.
PW-6000 Installation System Configuration via Web Interf ace PW -6000 Installa tion Guide , D ocument 800-00005, Revi sion A 15 4 System Configuration via W eb Interface The PW -6000 comes with Access Control Device Server Manager (ACDSM) . The ACDSM is a built-in web server , through which you can co nfigure network and other system settings.
16 www .honeyw ell.com PW-6000 Installation System Configuration via Web Interf ace 4.3 Hom e Page The first screen after the login is the home page whic h displays all the ava ilable config uration l.
PW-6000 Installation System Configuration via Web Interf ace PW -6000 Installa tion Guide , D ocument 800-00005, Revi sion A 17 4.4 Network Settings Click the Network link on the navigation bar to dis.
18 www .honeyw ell.com PW-6000 Installation System Configuration via Web Interf ace St atic IP Configuration Method 1. Click the St a t i c I P option button to assign a static IP address, and enter the following information in the appropriate fields: • IP Address • Subnet Mask • Default Gateway 2.
PW-6000 Installation System Configuration via Web Interf ace PW -6000 Installa tion Guide , D ocument 800-00005, Revi sion A 19 1. From PW6000 Communication Address dro p-down list, select one of the eight (0 to 7) available communication addresses for the PW -6000 board.
20 www .honeyw ell.com PW-6000 Installation System Configuration via Web Interf ace IP Client Connection T ype Figur e 9: PW -6000 Host Port Configurat ion Screen with IP Client Connection Note: The PW -6000 panel does not currently supp ort an IP Client connectio n.
PW-6000 Installation System Configuration via Web Interf ace PW -6000 Installa tion Guide , D ocument 800-00005, Revi sion A 21 Serial-RS232, Serial -RS485, Serial-Modem, or Se rial-CoBox Connection T ypes Figur e 10: PW -600 0 Host Port Configuration with Seria l RS-232 Connection 1.
22 www .honeyw ell.com PW-6000 Installation System Configuration via Web Interf ace 3. For the Alternate Host Port , make the follo wing selections: a.
PW-6000 Installation System Configuration via Web Interf ace PW -6000 Installa tion Guide , D ocument 800-00005, Revi sion A 23 4.7 User Configuration Click the Users link on the navigation bar to dis.
24 www .honeyw ell.com PW-6000 Installation System Configuration via Web Interf ace 3. Specify the maximum period of time a session will remain open withou t user activity . If the period expires without user activity , the user is logged out. After specifying the time period, click Save Session T imer to save the setting.
PW-6000 Installation System Configuratio n via Web Interface PW -6000 Installa tion Guide , D ocument 800-00005, Revision A 25 4.9 Apply Setting Screen Click the Apply Setting link on the n avigation .
26 www .honeyw ell.com PW-6000 Installation System Configuration via Web Interf ace.
PW -6000 In stallation and Configurati on Guide , Docume nt 800-00005, Revision A 27 Appendix A PW -6000 W e b Server and Pro-W atch Channels The PW -6000 web server ’ s host port configuration requires correspo n ding changes in the way the Pro-W a tch’ s channels are configured.
28 www.honeywell.com d. Click OK . e. From the Setting menu, select Apply , Reboot . The system will display the “Board is Restarting” message. 3. Set the port configurati on for the Pro-W atch channel: a. In Pro-W atch, click Hardware Configuration on the left navigation bar .
For more information: www .honeywell integrated .com Honeywell Access Systems 135 W . Forest Hill A ven ue Oak Creek, WI 53154 414-766-1700 414-766-1798 F ax European Office Boblingerstrasse 17 D-71101 Schonaich Ger many 49-7031-637-782 49-7031-637-769 F ax www .
デバイスHoneywell PW-6000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell PW-6000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell PW-6000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell PW-6000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell PW-6000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell PW-6000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell PW-6000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell PW-6000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell PW-6000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。