5/19/2008 1 of 15 Application Note: Fire-Lite IPDACT Set up for Installing Dealers These pictorial instructions should be used in conjunction with the formal PID (Product Installation Document) in cluded with the IPBRKT or IPENC as well as the instructions included with the IPDACT.
5/19/2008 2 of 15 Note: All of the above available at Fire-Lite Distribution The IDPACT requires 24VDC filtered regul ated power and a phone pair from the DACT of the fire alarm control panel.
5/19/2008 3 of 15 2. Mount the IPDACT onto the IPBRKT using the plastic standoffs that came with the IPBRKT. Screw the standoff through the holes on the IPDACT into the metal mating threaded stando ffs on the IPBRKT.
5/19/2008 4 of 15 4. Loop the 8 PIN cable supplied with t he IPDACT once through the large Ferrite Ring. Note that this cable is NOT used as an Ethernet Cable but to interconnect the dialer output of the panel to the input of the IPDACT. Plug the 8 PIN cable supplied with t he IPDACT into the Primary DACT port of the control panel .
5/19/2008 5 of 15 2. Installation using IPENC or HP300ULX The IPENC is used for mounting the IPDACT next to panels that cannot accept the IPBRKT directly inside the enclosure .
5/19/2008 6 of 15 The IPDACT requires a minimum of 300 mA of current. If an FACP cannot supply this minimum requirement, a separate power supply, such as the HP300ULX, may be used to supply the r equired current. The IPDACT can be mounted inside the HP300ULX power suppl y enclosure as described below: 1.
5/19/2008 7 of 15 Installation using 411UD for moni toring Alarm, Trouble and Supervisory dry con tacts from any FACP The 411UD can also be mounted next to the IPDACT inside the HP300ULX and used to monitor the Alarm, Trouble, and Supervisory dry contacts from any manufacturer’s fire alarm control panel.
5/19/2008 8 of 15 Set Connect using to COM1 then OK Note: if using a USB/Serial conver ter, select the COM port assigned to the converter •.
5/19/2008 9 of 15 • Set Port Settings to: Bits per second: 9600 Data bits: 8 Parity: none Stop bits: 1 Flow control: none ( very important ) Click OK • Press Enter and the word passw ord should ap.
5/19/2008 10 of 15 • At the menu options screen, shown below, select " C: Quick Install ".
5/19/2008 11 of 15 • Note: The following examples contain only sample settings • Enter the parameters given to you by the Central Station for each menu item --Quick Install-- a) DHCP client: OFF when static IP will be us ed. Set this to ON if an IP will be obtained automatically from a network router on a private network.
5/19/2008 12 of 15 e) Supervisory Main: 192.168.0.1 (note this is the primary receiver’s IP address assigned by central station) f) Supervisory Backup: 192.168.0.2 (note this is the secondary receiver’s IP address assigned by central station.) g) Maintenance: This is a third IP receiver setting that is not normally used.
5/19/2008 13 of 15 secondary port will use the backup phone line for 24 hour test signals or when the network may go down. See your panel’s manual for correct programming.
5/19/2008 14 of 15 The IP settings in the IPDACT work like this: • If you set the DHCP to ON, the IPDACT will broadcast a request for the IP parameters over the LAN network.
5/19/2008 15 of 15 Option “ g) IP Connectivity ” displays the IP settings that are running in the device. • If the IP Settings were not obtained through DHCP, the fixed ones entered in “ c) Quick Install ” are displayed, and actually used.
デバイスHoneywell Smoke Alarmの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell Smoke Alarmをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell Smoke Alarmの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell Smoke Alarmの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell Smoke Alarmで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell Smoke Alarmを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell Smoke Alarmの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell Smoke Alarmに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell Smoke Alarmデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。