Installation Instructions Installation Instructions (In Toronto Area only: 1-905-3061093) Certified to comply with ASME A112.19.2M © 2008 AS America, Inc. NOTE TO INSTALLER: Please give this manual to the customer after installation. SELECTRONIC™ PROXIMITY URINAL FLUSH V AL VE 0.
Installation Instructions 1 1 2 3 4 5 6 7 8 9 DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INST ALLATION IS COMPLETE. 5. Sweat Solder Adapter 6. Cover Tube 7. Wall Escutcheon 8. Supply Stop 9. Installation Instructions 1. Flush Valve Assembly 2.
Installation Instructions RECOMMENDED TOOLS; Fig. 2 Fig. 2 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Teflon Tape Flat Blade Screwdriver (For adjusting Supply Stop) Adjustable Wrench Tape Measure Hacksaw Tubing Cutter File For Sweat Connection; Solder and Torch 2.
Installation Instructions 1 1 2 3 4 5 1 4 2 3 Fig. 4 Fig. 5 1. Measure from finished wall to first thread of Adapter or threaded supply pipe (dimension “X”). Cut COVER TUBE (1) to length (X). Apply Teflon Tape to the threaded end of the Adapter or supply pipe.
Installation Instructions 4 M968567 Rev .1.2 1 CLOCKWISE CLOSES CONTROL STOP COUNTER-CLOCKWISE OPENS CONTROL STOP REMOVE COVER Fig. 6 1. Remove COVER (1) from SUPPLY STOP (2) . 2. With a flat blade screwdriver open SUPPLY STOP (2) . 3. Turn on water supply to flush line of any debris or sediment.
Installation Instructions M968567 Rev .1.2 5 7 9 6 10 2 5 8 1 121mm,+13mm, -6mm (4-3/4)(+1/2, -1/4) Fig. 8b Fig. 9 2 REMOVE COVER CLOCKWISE CLOSES CONTROL STOP COUNTER-CLOCKWISE OPENS CONTROL STOP IMP.
Installation Instructions M968567 Rev .1.2 6 Fig. 12b 3 9 1. Remove COVER (1) from SUPPLY STOP (2) if installed. Fig. 10. 2. Turn water supply off. Fig. 10. 3. Loosen SPUD COUPLING NUT (3) . Unthread COUPLING NUT (4) and VACUUM BREAKER COUPLING NUT (5) .
Installation Instructions M968567 Rev .1.2 HOW TO SET DETECTION RANGE (If Required) ; Fig. 13 6 6 3 Fig. 13b Fig. 13 Fig. 14 Fig. 14a Fig. 14b VIEW “A” 11 DETECTION ZONE 38mm TO 787mm (1-1/2 TO 31) 1 Fig.
Installation Instructions M968567 Rev .1.2 8 IS STOP VALVE OPEN? LOOK FOR REPEATED DOUBLE FLASH ON SENSOR YES INSTALL NEW BATTERY TRY MANUAL VALVE BUTTON; WILL THE UNIT FLUSH? NO REPLACE PISTON KIT IN.
Installation Instructions M968567 Rev .1.2 9 HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1 (800) 442-1902 W eekdays 8:00 a.m. to 6:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) W eekdays 8:00 a.m. to 7:00 p.
デバイスAmerican Standard 6063.101の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Standard 6063.101をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Standard 6063.101の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Standard 6063.101の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Standard 6063.101で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Standard 6063.101を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Standard 6063.101の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Standard 6063.101に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Standard 6063.101デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。