HP (Hewlett-Packard)メーカーHP NetRAID-4Mの使用説明書/サービス説明書
ページ先へ移動 of 42
HP NetServer Installation Guide For the HP NetRAID-4M and Microsoft Cluster Services 1 November 2001.
ii Notice The information in this document is subject to change without notice. Hewlett - Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
HP NetRAID - 4M Clus ter Installation Guide Contents iii Contents Introduction ........................................................................................................................................ iv Intended Audience ..............
HP NetRAID - 4M Cluster Installation Guide Introduction iv Introduction The following pages contain a cursory set of proc edures for setting up the clustering components of HP NetServers with the HP NetRAID - 4M disk controller running Microsoft Windows 2000 Advanced Server operating system.
HP NetRAID - 4M Cluster Installation Guide Introduction v Chapter 14, Working with Diskset s, explains how to manage a new object type called the diskse t, which is required to create containers on shared s torage.
HP NetRAID - 4M Cluster Services Installation Guide Overview 1 1 Overview 1.1 Software and Networking Requirements • Microsoft Windows 2000 Advanced Server with the latest service pack installed on .
HP NetRAID - 4M Cluster Services Installation Guide Overview 2 1.4 Alternative Installation Sequence NOTE For the purpose of illustration, the two server nodes depicted in this guide are referred to as Server A, or node A, the first node to establish the cluster, and Server B, or node B, the second node to join the same cluster.
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 4 2 NetRAID - 4M – Cluster Hardware Component Installation • Create the installation diskettes required for the .
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 5 2.1 Create Installation Floppy Diskettes NOTE Refer to an HP Ne tServer Cluster Configuration Guide for the supported versions of the Navigator CD, server BIOS and NetRAID - 4M firmware and driver.
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 6 2.2 Install the NetRAID-4M and Heartbeat NIC 1. Power off both Server A and Server B. 2. Disconnect all cables from the back of Server A. 3. If working on a racked server, extend the rack enclosure foot.
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 7 11. Connect one end of a 10BaseT Crossover cable to the HP D5013B NIC that was just installed i nto Server A. 12. DO NOT connect the HP NetRAID - 4M controller SCSI cables at this time.
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 8 24. When the update is complete, select the option to exit then press E to exit to DOS. 25. Remove the floppy from the server floppy drive and power the server off. 26.
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 9 CAUTION Connecting to adjacent channels, i.e.: 0 and 1, or 2 and 3, on the HP NetRAID - 4M requires SCSI offset cables. Do NOT try and force connecting any other SCSI cables to channels next to each other or the controller may become damaged.
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 10 2.3 Set NetRAID-4M BIOS Options Set Controller Configuration Options 1. Power on Server A. Do not power on Server B at this time. 2. During the boot process, press Ctrl - A at the HP Ne tRAID - 4M configuration prompt.
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 11 NOTE When the Domain Validati on feature is enabled, the HP NetRAID - 4M controller performs a series of Read/Write buffer tests to check bus integrity and has the option of reducing the transfer rate if necessary, until data integrity is ensured.
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 12 6. Inser t the NOS Drivers diskette into the floppy drive. 7. De - select all options for searching for the driver other than the Floppy Disk drives, click Next . 8.
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 13 9. If th ere is no digital signature found, click Yes to continue. 10. After the driver files for the controller, including the HP NetRAID - 4M Management Device driver, have been copied from the floppy disk, click Finish .
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 14 17. From the General tab screen, de - select all components from the middle pan el other than Internet Protocol (TCP/IP).
HP NetRAID - 4M Cluster Services Installation Guide Hardware, Drivers and Utilities 15 24. Click Yes to acknowledge the empty WINS addr ess message, and the click OK in the Properties window. 25. Click OK to acknowledge the empty DNS list message. Click OK at the Properties window.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 16 3 NetRAID - 4M - Installing Windows 2000 Cluster Services • Install Windows 2000 Clu ster Services on bo.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 17 3.1 Server A: Create Cluster Service User Account 1. Log on to the domain at Server A as an administrator. 2. Open the Active Directory Users and Computer utility from the Administrative Tools Start menu.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 18 8. Enter a password f or the cluster service user account. 9. Select the options User cannot change password and Password never expires . Click Next and then click Finish .
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 19 3. Select the Cluster Service option from the list of services and click Next . 4. Insert the Windows 2000 Advanced Server CD - ROM in the CD - ROM drive. If the Windows 2000 Advanced Server splash screen appears, click Exit .
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 20 7. Click Yes to the prompt to exit the setup. 8. Click Finish to close the Cluster Service Installation wizard. 9. Close the Add/Remove Programs and Control Panel windows.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 21 19. On the second Network Connection screen, enter the public LAN name, (e.g.: Public Network ), and an IP address and then select the option to Enable this network for cluster use .
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 22 22. Click Finish to complete the installation of Cluster Services. 23. At the pro mpt that Cluster Services has successfully started, click OK . 24. Exit the command prompt window.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 23 25. When the HP NetRAID - 4M C luster software installation is complete, remove the diskette from the floppy drive. Click Finish . 26. Open the Cluster Administrator utility, Start > Programs > Administrative Tools > Cluster Administrator.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 24 3.3 Server B: Install Cluster Services 1. Log onto Server B. 2. Open the Control Panel screen and double - click on the Add/Remove Programs icon. 3. Click on the Add/Remove Windows Components and select the Cluster Servic e option.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 25 Server B: Install HP NetRAID - 4M Cluster Add - on software 16.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 26 3.4 Configure the Cluster Shared Quorum Using the NetRAID - 4M FAST Utility 1. On Server A , from the Windows 2000 Start button start the NetRAID - 4M FAST utility.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 27 7. Leave the options Attached and Re - initialize disk selected.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 28 This container ’ s write cache will be set to “ Enable when protected ” . However, because the container resides on a clustered controller ’ s shared channel the write cache will not be enabled.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 29 22. Expand the v iew to see all disk space in the Disk Management screen. Right - click on the Unallocated Space representing the new container that appears in the window and select the Create a Partition option.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 30 NOTE When formatting partitions for a container using the Disk Administrator or Disk Management utility, Quick Format is an option.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 31 7. For the Group name select Cluster Group and click Next . 8. Change or confirm settings in the Possible Owners screen and then click Next . 9. Make no changes in the Depe ndencies windows and click Next .
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 32 CAUTION The shared quorum SHOULD now be offline, and a red X appears next to Cluster Group. 13. Right - click on the Quorum resource that is in an offline state.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 33 17. From the Quorum Resource drop list, select the shared Quorumname item (the example is Cluster1 ) and then click OK . 18. Click once on the Cluster Group in the left panel.
HP NetRAID - 4M Cluster Services Installation Guide Cluster Software Components and Quorum 34 3. Observe the ownership column of the Cluster Group resources in the right panel. The ownership should change to Server B. 4. Move the Cluster Group back t o Server A .
HP NetRAID - 4M Cluster Services Installation Guide Creating Shared Disksets 35 4 Expand Shared Storage for Cluster Services • Create and initialize additional NetRAID - 4M containers • Create Win.
HP NetRAID - 4M Cluster Services Installation Guide Creating Shared Disksets 36 4.1 Create Shared Disksets, Containers and NTFS Partitions 1. On Server A, open the NetRAID - 4M FAST utility and Open the NetRAID - 4M controller connecting to shared storage.
HP NetRAID - 4M Cluster Services Installation Guide Creating Shared Disksets 37 14. In the FAST Container View console you should see the new logical containers as they are being initialized, as shown below: 15. Wait for all disk initialization to complete before continuing.
HP NetRAID - 4M Cluster Services Installation Guide Creating Shared Disksets 38 4.2 Create NetRAID-4M Diskset Resources for Data Drives 1. From either server, open the Cluster Administrator utility 2. In the left panel click once on the Groups folder.
デバイスHP (Hewlett-Packard) HP NetRAID-4Mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP (Hewlett-Packard) HP NetRAID-4Mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP (Hewlett-Packard) HP NetRAID-4Mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP (Hewlett-Packard) HP NetRAID-4Mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP (Hewlett-Packard) HP NetRAID-4Mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP (Hewlett-Packard) HP NetRAID-4Mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP (Hewlett-Packard) HP NetRAID-4Mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP (Hewlett-Packard) HP NetRAID-4Mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP (Hewlett-Packard) HP NetRAID-4Mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。