OWNER'S MANUAL MODEL 24SII DATA EXCHANGE SYSTEM Rev. 2.00 BayTech publi cation #U 140E084-01.
Thank you for selecti ng a Bay Tech Model 24SII Data Ex change System. The data prov ided in this Owner 's Manual ex plai ns the var ious w ays you can oper ate your unit and configur e it to y our computer sy stem.
NOTE: The information contained in this document is subject to change w ithout notice. Copy rig ht 1992 by Bay Technical Associates, Inc. LaserShare, Pr int Master, Tel plex, and Tran x are regi stered tradem arks of Bay Technical Associ ates, Inc.
TA BLE OF CONTENTS 1 GENERAL INFORMATION .............................................. 1 2 SPECIFICATIONS ........................................................... 5 3 QUICK START ............................................................... 10 4 INSTALLATION .
5.5 I/O MODULE M24SII-V07: EIA-232/EIA-422 SER IAL PORTS W ITH RJ-45/RJ-11 MODULAR CONNECTORS ........... 35 5.5.1 8-W IRE CONDUCTOR OPERAT ION....... 36 5.5.2 4-W IRE CONDUCTOR OPERAT ION....... 38 5.5.2.1 EIA-232 PORTS USING BIDIRECTIONAL PRINT E R SHARING MODE .
7 OPERATION .................................................................. 51 7.1 COMPUTER-TO-PERIPHERAL OPERAT ION .... 51 7.1.1 SHARING A SINGLE PERIPHERAL ........ 51 7.1.2 CONTEND ING FOR M ULTIPLE PERIPHERALS .................................
8.10 ENABLE/DISABLE FORM FEED MODE ............ 87 8.11 PROGRAM I.D. PAGE MESSAGE...................... 89 8.12 ENABLE/DISABLE I.D. PAGE MESSAGE .......... 90 8.13 SELECT PRINT SCHEDULE FOR I.D. PAGE .... 92 8.14 PROGRAM DEFAULT PRINTE R ASSIGNMENT 94 8.
APPENDIX A CABLING TO MODEL 24SII ................................................... 100 A.1 BETW EEN M24SII-V03 I/O MODULE AND IBM PC OR PS/2 (DB-25) ......................................... 100 A.2 BETW EEN M24SII-V03 I/O MODULE AND IBM AT (DE-9) .
APPENDIX B MODEL 24SII MODULE INSTALLATION ............................... 117 B.1 MODEL 24SII I/O MODULE INSTALLATION.... 117 B.2 MODEL 24SII MEMORY MODULE INSTALLATION ................................................. 119 APPENDIX C BUFFER EXPANSION/EPROM UPGRADE .
APPENDIX E TROUBLESHOOTING ............................................................ 137 APPENDIX F INDEX ..........................................
The BayTech Model 24SII Data Exchang e Sy stem (DES) is a hig h performance peripheral sharing solution offering v ersati le and flexi ble connectiv ity between computer s and var ious peri pheral dev ices.
Each port offers high speed data communicati on wi th unidir ectional serial thr oughput up to 460k bi ts per second (bps) and parallel speeds exceedi ng 60k character s per second ( cps). The Model 24SII controller board is used pr imaril y as a data communi cations bus w ith throughput capability up to 5.
The Model 24SII's g enerous buil t-in buffer also sav es valuabl e computer time by spooling data until the pr inter or plotter can r eceiv e it, keeping your users and computers w orking full time instead of wai ting . The spooli ng buffer on the Model 24SII D ES can rang e from 0 MB to 16MB in 1M B or 4MB i ncrements.
BayTech sells a high speed ser ial modul e for the Model 24SII DES whi ch supports EIA-422 pr otocol (M 24SII-V07). Thi s allow s f or long cable distances using RJ- 11 (4-w ir e) or R J-45 (8- w ire) modul ar cabling .
BA SE UNIT: Supports 24 ports of communication at up to 5.5M bps total throug hput speeds. I/O Modules : Four ports per module. Max imum 6 modules per unit. M ust have a mi nimum of 4 serial ports per uni t.
FA CTORY POW ER-UP DEFA ULT CONFIGURA TIONS: Serial ports: Baud rate: 9600. Word size: 8 bits. Parity : None. XON/XOFF: Off. Printer sharing mode (high speed serial modules only ): Bidir ectional. 4-Wire/8-Wire Operation (M 24SII-V07 high speed serial module only ): 8-w ire.
Printer Sharing Mode (high speed serial modules only ): (per module) Unidi rectional or bidir ectional. 4-Wire/8-Wire Operation (M 24SII-V07 high speed serial module only : 4-w ire or 8-w ire. Word size*: 7 or 8 bi ts. Parity *: Even, odd or none. Stop bits*: 1 or 2.
MODULES 4 PORT HIGH SPEED SERIA L EIA -232 DES Interface: Asy nchronous EIA-232, - 12v mark, +12v space. Full duplex . Connectors: Avai lable i n DB-25 mal e DTE (Bay Tech part #M24SII-V03) , DB-25 female D CE (B ayTech par t #M24SII-V04 or RJ-45 ( Baytech par t #M24SII-V06A) .
4 PORT HIGH SPEED PA RA LLEL DES Interface: Centronics pr otocol. Connectors: DB-25 female ( BayTech par t #M24SII- V02). Handshaking: BUSY (pi n 11); ACK (pi n 10) -out onl y. Flow Control Buffer: 1k character i nput/output. Speed: 60k cps output; 58k cps input.
This section pr ovi des basic instal lation instr uctions for persons knowl edgeable i n the area of computer equi pment installati on. In this section, w e assume that the Model 24SII DES has nev er been conf igured (i.
Step Inst ruc tions / Applic ation Ques tions Act i on/ Speci al I nstruc tions printer or plot ter, you m ust reconfi gure the Port Des ignation of a parallel port on the Model 24SI I DE S to be a pri nt er port . Additi onal l y you m ust reconfi gure t he Port Des i gnat ion for P ort 2 of Module 1 to a com puter port .
The information contained in this section is pr ovi ded as an over vi ew and guide to config uration and set-up of the Model 24SII DES. The appropriate secti ons of the manual should be referred to for more in- depth information pertaining to a specific function or for alter nativ e methods.
To run INSTALL, use the follow ing procedur e: 1. Insert the so ftware utility diskette in to drive A (or drive B) and from the prompt ty pe INSTA LL followed by ENTER . 2. A menu titled "Drive & Directory Definitions" will appear on y our screen.
The standard Model 24SII D ES req uires 115 VAC, 50/60 H z. pow er and comes wi th a three-pr ong pow er cor d. Do not attempt to operate the unit w ith a tw o-prong socket or adaptor . 230 VAC, 50/60 Hz . is optional. The Model 24SII DES pow ers-up when y ou press the pow er switch, located on the front of the unit, to "ON".
Connect the proper ser ial cabl e between C OMx (w here x = 1, 2, 3, or 4) of a PC, or dumb ter minal, to Port 1 of Module 1 (the master configuration por t).
Serial ports pow er-up from the factory at: 9600 baud rate 8 bit w ord size 1 stop bit no parity XON/X OFF disabled Printer shar ing mode: Bi directi onal.
If using an IBM PC or compatible to configur e the Model 24SII D ES, first make a copy of the BayTech supplied support softw are disk and store the orig inal in a safe place. (Refer to y our DOS manual for copy instructions). You w ill be using the TERM program created by running the INSTALL prog ram ( see Section 4.
3. Refer to the upper r ight hand cor ner of the screen for Handshaking line status. RTS, CTS, DSR , and DTR should all be HIGH. The DCD line is not looked at by the terminal emulati on prog ram therefore its status can be ignor ed. If these signals ar e not high at thi s point, check to ensure the corr ect cable is connected.
Ref e r to Section 8 for in-depth instructi ons on configurati on options. Model 24SII DES CONFIG URATION GUIDE Menu Options Factory Default Us er Opt i ons Notes Stat us n/a n/a Use to revi ew the s t at us of the current c onfigurat i on of the Model 24SI I DE S.
Model 24SII DES CONFIG URATION GUIDE Menu Options Factory Default Us er Opt i ons Notes W ord Siz e: 8 Stop Bits: 1 Parity: none XON / XO F F X mit: off XON / XO F F Recv: of f Printer Sharing Mode: bidirect ional 4-W ire/ 8-W ire Operation: 8- wir e 460.
Model 24SII DES CONFIG URATION GUIDE Menu Options Factory Default Us er Opt i ons Notes (beginning) has been selec t ed. Mode B recognizes t he end of a print job only by inactiv ity tim eout periods. I t will not recognize m anual disc onnec t codes .
This section i s intended to prov ide i nstructions on how to set up y our PC to w ork w ith the M odel 24SII DES w ith r espect to the BayTech software (i f you intend to use it ) and special consi derations to keep i n mind w hen connecting y our PC to the Model 24SII DES in par allel or in serial.
You w ill also need to change the serial port configuration of your PC COM por t to match that of the Model 24SII's Serial Port Configur ation. If you will be using the Model 24SII's factory.
If you are connecting y our PC to the M odel 24SII DES in ser ial and are not goi ng to use the Bay Tech software, y ou w ould not need to modify y our PATH command or incl ude the RAM EXEC command in the AUTOEXEC.
The pin assig nment for the DB-25 connector i s simil ar to the IBM PC parallel connector and uses the follow ing signal s for communication: DB-25 ST ANDARD CENTRONICS T T L LEVELS Bay Tech Cable par.
! "#$ .
If you are inter facing a DCE dev ice to the Model 24SII DES (D TE), you must use a one- to-one or str aight cabl e as shown i n Figure 3 on the followi ng pag e. If you are inter facing a DTE dev ice to the Model 24SII DES (DTE) , y ou must use a crossed cable as show n in Figure 4 on the follow ing page.
NOTE: Please refer to Appendix A for recommended cabli ng diagr ams between the M odel 24SII DES and v ari ous computers and printer s. 1 2 3 4 5 7 20 20 7 5 4 3 2 1 PGND TXD RXD RTS CTS SGND DTR FEMA.
! "#$ .
If you are inter facing a DTE dev ice to the Model 24SII DES (DC E), you must use a one- to-one or str aight cabl e as shown i n Figure 5 on the followi ng pag e. If you are inter facing a DCE dev ice to the Model 24SII DES (DC E), y ou must use a crossed cable as show n in Figure 6 on the follow ing page.
NOTE: Please refer to Appendix A for recommended cabli ng diagr ams between the M odel 24SII DES and v ari ous computers and printer s..
! "# " #$ .
NOTE: Please confirm that you hav e the M24SII-V06A module. Check the top of the module for the part number. If you hav e an M24SII-V06 module ( i.e., no A suffix), pl ease call a Bay Tech Applicati ons Engineer for the correct pin/si gnal definiti on and the correct adapter i nformation.
! "#$ ! % !% .
If you will be u sin g 4-wire Operatio n , pleas e use the ref e rence ch art below to determine the appl icabl e sections based on y our appl ication. 4-WIRE OPERATION OPTION S Application Printer S haring Mode Protoc ol See Sec t ion: Bidirec tional Unidi rectional EIA -232 EIA-422 1 X X 5.
If you are connecting an EIA-232 dev ice to the M 24SII-V07 module using 8- wi re Operati on, please see Appendix A.5 for devi ce adapter pinouts and recommended cabl ing.
NOTE: Ports using this configuration will support X ON/XOFF handshaking onl y.
COMPUTER PORTS NOTE: Computer ports using this configuration will support hardw are handshaking onl y.
PRINTER PORTS NOTE: Printer ports using this configuration will support hardw are handshaking onl y. Y ou must ensure har dwar e handshaking i s supported by the eq uipment that will connect to these ports.
NOTE: Ports using this configuration will support X ON/XOFF handshaking onl y.
If you are connecting a dev ice other than another BayTech product, you must r efer to the operator's manual for y our eq uipment to determine w hich pins are defined as TX+ , TX -, RX +, and RX -.
W hen connecting an EIA- 422 dev ice to a computer por t on the M24SII-V07 I/O module using 4-w ire Oper ation and unidirectional Printer Shar ing M ode, the cable req uired to connect the tw o devices must have R X+ w ired to TX +, and R X- w ired to TX -, HSO+ w ired to HSI+, and HSO- w ired to H SI-.
PRINTER PORTS NOTE: Printer ports using this configuration will support hardw are handshaking onl y. Y ou must ensure har dwar e handshaking i s supported by the eq uipment that will connect to these ports.
NOTE: If your EIA-422 dev ice has onl y one output har dw are handshake line (i .e., no HSO+ and H SO-), connect thi s sing le handshake line to HSI- on the M24SII-V07 modul e (Pin 5) .
The Port Log ical N ame is si mply an aid to identi fying w hich dev ice is connected to whi ch port. It is used in the configurati on menus and the I.
' "# ( You may configur e the number of printer ports on the M 24SII-V02 parallel module to be 0 to 4.
If the computer is communicating w ith 7 bit w o rd size w ith pari ty enabled, the 8th or pari ty bit is masked from the Port Sel ect Code before it is ex amined, all owi ng y ou to send the Port Sel ect Code w ith odd or ev en parit y. Factory default is $SELECT.
The Model 24SII DES will translate for serial devices using different configurati ons. This al low s y ou to mix -and- match dev ices hav ing different configurations.
& The Model 24SII DES has four For m Feed Modes allow ing y ou to determine w hen form feed occurs at the printers you ar e selecting : at the beginni ng of printing , at the end of printing , or both. This feature is useful w hen sending D OS files to a laser pr inter.
The Model 24SII Data Ex change System allow s peripheral (pr inter, plotter) shar ing , specific peripher al selecti on or peripher al contention, and buff e ring of print data.
In multiple pr inter appli cations, the M odel 24SII DES g iv es you the capability of sending print jobs to the first available printer (contention mode).
The Model 24SII DES pow ers-up from the factory in contention mode. .
The port select seq uence may be sent as a separ ate ASCII file preceding the print job, v ia DOS batch files, as part of a printer initialization strin g, or by using the u tility software.
In Port Select Mode B (printer sel ection at begi nning of pri nting) , a print j ob is ended only when no characters are recei v ed by the M odel 24SII DES from the computer for the specified Input Inactiv ity Timeout period onl y. CA UTION: The Input Inactivi ty Ti meout should not be set to 0 (z ero) seconds (disabl ed) in Port Sel ect Mode B.
If a computer wishes to cl ear the buffer, the computer sends the Port Select Code follow ed by CLR and a terminating character (Enter/Retur n or Line Feed) to the Model 24SII D ES. This comm and will only affect print jobs originated by that particular computer.
The Model 24SII Data Ex change System allow s pairs of computers (or computers and other dev ices such as modems, scales, data collection eq uipment, etc.
Do not send both Enter/Retur n and Line Feed as the terminati ng character. The M odel 24SII DES looks for either Enter/Retur n or Line Feed as the terminating character, but not both.
NOTE: Using R AMEX EC to select another computer port is not sugg ested. This is because R AMEX EC does not prov ide full duplex communication so y ou cannot see the On Line or Busy message if you attempt to use R AMEX EC to deter mine w hether or not you g ot connection to the other computer por t.
For ex ample, suppose y ou want to communi cate w ith a 2400 baud modem connected to Port 2 of Module 2 and y our PC i s connected to a computer port set at the M odel 24SII's factory default seri al configuration ( 9600 baud, 8 data bit, 1 stop bit, no par ity , and XON/X OFF disabl ed).
BETWEEN COMPUTER A ND PERIPHERA L THROUGH MODEL 24SII W hen a.
BETWEEN COMPUTER A ND COMPUTER THROUGH MODEL 24SII W hen Computer A tr ansmits data to C omputer B throug h the Model 24SII DES, the data is r eceiv ed from Computer A and stored i n a 512-character buff er which in tur n retransmi ts it to Computer B.
BETWEEN COMPUTER A ND PERIPHERA L THROUGH MODEL 24SII W hen a computer tr ansmits data to a peri pheral dev ic e throug h a computer port on the M odel 24SII DES, the data is receiv ed and stored in the spooli ng buffer (standard 1M B; optional up to 16MB) whi ch in turn r etransmits it to a per ipheral devi ce throug h a printer port.
W hen the buffer of the Model 24SII D ES can receiv e more data, the Model 24SII DES will send an X ON to Computer A. NOTE: For computers sending binary data and using XON/X OFF handshaking, the i nput flow contr ol (Recv ) should be enabled and the output flow control (Xmit) should be disabled.
This command should be enter ed in all capitals w ith only one space between EC HO and the $. Please r efer to you DOS manual for instructions on creati ng DOS batch files. Progr ams such as W ord Perfect and W o rdStar typical ly send a printer initial iz ation string before any data.
& Configurati on changes for the entir e Model 24SII DES ar e made through the master configurati on port w hich is Port 1 of Module 1. Port 1 of Module 1 must alw ays be a serial por t to allow conf igurati on to occur.
To access the configuration mode of the Model 24SII DES, use the follow ing procedure: 1. Connect a dumb ter minal ( or a PC r unning a terminal emulation pr ogr am) to the master config uration por t (Port 1 of Module 1) or to any serial computer port.
NOTE: A serial computer connected to a port other than Por t 1 of Module 1 cannot access configur ation mode for its module w hile the master configur ation port i s configur ing a module.
& OPTION A CCESSIBILITY: Through any seri al computer por t. The Model 24SII DES will respond to the receiv ing of Cont.
NOTE: If you happen to be configuring a M24SII- V02 high speed parall el module, the mai n configurati on menu is di fferent from the one shown on the pr evi ous page.
& OPTION A CCESSIBILITY: Through any seri al computer por t. By r esponding to the Enter Request: messag e at the end of the main configurati on menu (see Section 8.1 ) wi th "1" (Status), you may rev iew the status of the current configurati on of the Model 24SII DES.
----------------------------------- | Port | Logical Name |I.D. Page| | | (Printer) |Schedule | ----------------------------------- | 2 |Device B | Before | ----------------------------------- Strike .
& OPTION A CCESSIBILITY: Through any seri al computer por t. By r esponding to the Enter Request: messag e at the end of the main configurati on menu (see Section 8.
For ex ample, if you enter ed MAIN IBM , the Model 24SII D ES wi ll respond w ith an updated menu and a pr ompt to continue or ex it: -------------------------------------------------- | Port | Logica.
& NOTE: This section does not pertai n to the M24SII-V02 hi gh speed parall el module. OPTION A CCESSIBILITY: Through Por t 1 of Module 1 only . By r esponding to the Enter Request: messag e at the end of the main configurati on menu (see Section 8.
Enter P for Printer, C for Computer, ENTER for no change : W hen you str ike the Enter key for no change, the M odel 24SII DES will respond w ith a reconf igured status menu, similar to: -------------.
& ' "# ( NOTE: This section pertai ns only to the M24SII-V02 hi gh speed parall el module.
& OPTION A CCESSIBILITY: Through Por t 1 of Module 1 only . By r esponding to the Enter Request: messag e at the end of the main configurati on menu (see Section 8.
& OPTION A CCESSIBILITY: Through any seri al computer por t. By r esponding to the Enter Request: messag e at the end of the main configurati on mode (see Section 8.1 ) w ith "5" (Set Por t Select Mode) , you may change the method of selecting ports.
------------------------------------------ | Port | Logical Name |Timeout| Port | | | (Computer) |in sec |Sel Mode| ------------------------------------------ | 1 |Device A | 20 |Anytime | | 3 |Device.
CA UTION: If you have a M 24SII-V07 install ed as Module 1, do not configure Por t 1 of this module for any baud rate hi gher than 115,200 or you w ill locked out of configuration mode and unable to program the var ious features of the Model 24SII.
/The followi ng baud rates ar e supported for the tw o different printer sharing modes: Bidirecti onal: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, and 115.2k Unidir ectional: 9600, 115.2k, 230.4k, and 460.8k. For ex ample, to change the baud r ate to 115.
The Model 24SII DES will respond w ith: Stop/Restart Output upon Receiving of XON/XOFF ? (Y/N): XON/XOFF Sent Based on buffer Full/Empty Condition ? (Y/N): The first questi on addresses XO N/XOFF flow control in the transmit data direction. The second q uestion addresses X ON/X OFF flow control in the r eceiv e data direction.
You may now reconfigur e another port, or exi t by str iking the Enter key. The Model 24SII DES w ill now return to the main configuration menu wi th a message at the end as follow s: Copyright (c) Bay Technical Associates, 1990 Model 24SII Data Exchange System Rev.
&) " OPTION A CCESSIBILITY: Through any seri al computer por t. By r esponding to the Enter Request: messag e at the end of the main configurati on menu (see Section 8.
If 0 (zero) is entered, the Input Inactivi ty Timeout w ill be disabled, and the end of a print job will occur only w hen the com puter sends the Port Select C ode follow ed by a printer port number. * * * CA UTION! * * * Do not set the Input Inactivity Timeout to zero seconds w hen Port Select Mode B has been selected.
&# ! OPTION A CCESSIBILITY: Through any seri al computer por t. By r esponding to the Enter Request: messag e at the end of the main configurati on menu (see Section 8.
If no additional change i s req uired, stri ke the Enter key for no change, and the Model 24SII DES will respond w ith: Form Feed at the End of Printing is ( Off ) Enter 1 for ON, 2 for OFF , ENTER for no change : You should follow the same procedure as above to enable or disable form feed at the end of printing .
& OPTION A CCESSIBILITY: Through Por t 1 of Module 1 only . By r esponding to the Enter request: messag e at the end of the main configurati on menu ( see Section 8.
& ! OPTION A CCESSIBILITY: Through any seri al computer por t. By r esponding to the Enter Request: messag e at the end of the main configurati on menu ( see Section 8.
If no f urther change is r equir ed for Port 1, strike the Enter key, and the Model 24SII DES will respond w ith: ------------------------------------------- | Port | Logical Name | Form feed | I.
& OPTION A CCESSIBILITY: Through Por t 1 of Module 1 only . By r esponding to the Enter Request: messag e at the end of the main configurati on menu (see Section 8.
If no f urther change is r equir ed for Port 2, strike the Enter key. The Model 24SII DES will respond w ith the reconf igured status and the prompt: ----------------------------------- | Port | Logical Name |I.
& OPTION A CCESSIBILITY: Through any seri al computer por t. By r esponding to the Enter Request: messag e at the end of the main configurati on menu (see Section 8.
Enter the module number of the desired pri nter. For exampl e, if the desired pri nter is connected to M odule 6, enter "6" i n response to the prompt. The Model 24SII DES will respond w ith: Default Port is 2 Enter New Value (1 to 4), or ENTER for no change : Enter the port number of Module 6 that the desir ed printer is connected to.
& OPTION A CCESSIBILITY: Through Por t 1 of Module 1 only . By r esponding to the Enter Request: messag e at the end of the main configurati on menu (see Section 8.
) Since there are no adj ustments and no movi ng par ts in the Model 24SII DES, prev entativ e maintenance is unnecessary . If you find it necessary to retur n the Model 24SII DES to the factory for warr anty w ork or factory-set chang es, follow the procedure l isted under Section 10 for repacking.
In the event that y ou hav e problems w ith the Model 24SII DES, BayTech has a staff of applicati ons engineer s on duty to assi st you from 7 am to 6 pm (CST or CDT), M onday throug h Friday .
.
+ 2 3 4 5 6 7 20 7 6 5 4 3 2 TXD RXD RTS CTS DSR SGND DTR FEMALE DB-25 DTR SGND DSR CTS RTS RXD TXD 20 MO.
3 7 20 20 8 7 6 5 2 RXD SGND DTR FEMALE DB-25 MODEL 24 DTE FEMALE DB-25 PC DTR DCD SGND DSR CTS TXD PC FEMALE DB-25 MODEL 24 DTE FEMALE DB-25 2 3 4 5 6 7 20 20 7 5 3 2 TXD RXD RTS CTS DSR SGND DTR DTR.
2 3 4 5 7 7 6 5 4 3 2 TXD RXD RTS CTS SGND DTR FEMALE DB-25 DTR DSR RTS RXD TXD 20 MODEL 24 DTE FEMALE DB-9 AT CTS SGND 8 1 DCD DCD 1 8 SGND CTS AT FEMALE DB-9 MODEL 24 DTE TXD RXD RTS DSR DTR FEMALE .
DCD 1 8 SGND CTS AT FEMALE DB-9 MODEL 24 DTE 20 TXD DSR DTR FEMALE DB-25 DTR SGND RXD 3 4 5 6 7 3 2 3 5 7 6 5 4 3 2 TXD RXD CTS SGND DTR FEMALE DB-25 DTR DSR RXD TXD 20 MODEL 24 DTE FEMALE DE-9 AT CTS.
2 3 4 5 6 7 20 7 6 5 4 3 2 TXD RXD RTS CTS DSR SGND DTR FEMALE DB-25 DTR SGND DSR CTS RTS RXD TXD 20 MODEL 24 DTE HP LASERJET MALE DB-25 MALE DB-25 HP LASERJET MODEL 24 DTE TXD RXD RTS CTS DSR SGND FE.
MINIMUM CA BLING USING HARDWA RE HA NDSHAKING MALE DB-25 HP LASERJET MODEL 24 DTE TXD RXD RTS CTS DSR SGND DTR FEMALE DB-25 SGND CTS RXD TXD 2 3 4 5 6 7 20 7 5 3 2.
A.4 BETW EEN MODEL 24SI I AND ANY CENTRONICS PRINTER 1 2 3 4 5 6 7 8 19 21 8 7 6 5 4 3 2 1 36 - PIN CENTRONICS PRINTER MODEL 24 MALE DB-25 STROBE DATA 0 DATA 1 DATA 2 DATA 3 DATA 4 DATA 5 DATA 6 DATA .
A.5 MODUL AR CABLING U SING M24SII-V06A I/O MODULE COMPUTER INT E RFACE To interface your computers or ter minals to the Model 24SII using EIA-232 protocol, refer to the RJ -45 adapter dr awi ngs bel ow. R efer to Figure 13 if your computer s or terminal s have D B-25 male connector s (most IBM X T and PS/2 type computers) .
PRI NTE R/ PLO TTER IN TER FA CE To interface your EIA-232 seri al printer s or pl otters to the Model 24SII ref e r to Figure 15 . 1 2 3 4 5 6 7 8 20 8 7 6 5 4 3 2 RTS RX DCD DTR GND DSR TX CTS MALE .
MODEM INTE RFA CE To interface your asynchr onous modem to the Model 24SII r efer to Figure 16 . IMPORTA NT : W hen modular connectors ar e used as shown i n Figures 13 - 16 above, cr ossed RJ-45 cabl es are req uired. The R J-45 cable, betw een the Print M aster and y our connected equi pment must be crossed.
A.6 M24SII-V07 MODULE: EIA-422/EIA-232 PROTOCOL SELECT ION AND EXTERNAL POWER You may configur e indiv idual ports on the M24SII- V07 module to communicate w ith either EIA-422 (default) or EIA-232 protocol . Protocol selecti on is accompli shed v ia jumper setti ng.
A.7 MODULAR CABLING USING M24SII-V07 I/O MODULE A.7.1 RJ-45 (8-WIRE) CABLING NOTE: If you have configur ed a port on the M24SII- V07 I/O module to use EIA-232 Protocol and 8- w ire Oper ation, please refer to Appendix A.5 for recommended adapter/cabl ing i nformation.
A.7.2 RJ-11 (4-WIRE) CABLING USING EIA-232 PROTOCOL AND BIDIRECTIONAL PRINT ER SHARING MODE COMPUTER INT E RFACE To interface your computers or ter minals to the M24SII- V07 module using 4- wi re and bidi rectional oper ation, refer to the RJ- 11 adapter draw ings below .
PRI NTE R/ PLO TTER IN TER FA CE To interface your EIA-232 pri nters or pl otters to the M24SII- V07 module using 4-w ir e and bidir ectional oper ation, r efer to the adapter draw ing show in Figure 21 . FIGURE 21: Printer/Pl otte r A da pter Bay Tech Part No.
A.7.3 RJ-11 (4-WIRE) CABLING USING EIA- 232 PROTOCOL AND UNIDIRECTIONAL PRINTER SHARING MODE COMPUTER INT E RFACE To interface your computers or ter minals to the M24SII- V07 module using 4- wi re and unidi rectional oper ation, refer to the RJ- 11 adapter draw ings below .
PRI NTE R/ PLO TTER IN TER FA CE To interface your EIA-232 pri nters or pl otters to the M24SII- V07 module using 4-w ir e and unidir ectional oper ation, r efer to the adapter draw ing show in Figure 25 . IMPORTA NT W hen modular adapters are used as show n in Figures 19 - 21 above, cr ossed RJ-11 cabl es are req uired.
A.7.4 RJ-11 (4-WIRE) CABLING USING EIA-422 PROTOCOL NOTE: This section assumes y ou are connecting either a Bay T ech Tran-x converter or another Bay Tech devi ce using EIA-422 protocol and 4-w ir e operation. W hen a port on the M24SII- V07 module is config ured to use EIA-422 protocol and 4-w ire Operation, RJ- 11 crossed cables ar e requi red.
APPENDIX B MODEL 24SII MODULE INSTALLAT ION B.1 MODEL 24SII I/O MODULE INSTALLAT ION Each I/O module prov ided by Bay Tech includes one of the following L-shaped modules: You w ill need the following equipment: 1 x str aight- slot screw driver 1 x phillips-head screw driver 1.
NOTE: Module 1 must be a seri al module ( i.e., M odule 1 may be occupied by any modul e part number other than M24SII- V02). 3. Remov e the flat aluminum plate cov ering the slots into w hich the new module w ill be installed by loosening the 2 straight slot screw s and then remov ing the pl ate from the rear panel .
B.2 MODEL 24SII MEMORY MODULE INSTALLAT ION Each memory module prov ided by Bay Tech includes one of the followi ng modules: M 24SII-M01 ( 0 to 4MB) or M24SII-M 02 (0 to 16MB). You w ill need the following equipment: 1 x phillips-head screw driver 1 x 3/8 i n.
CA UTION: You must instal l the new memory module i nto the appropriate l ocation to assure pr oper operation. Y ou may only have one ty pe of memory modul e install ed. 5. Remov e the four nuts on the appropri ate location w ith the nut driv er or socket and place the nuts in a safe place.
APPENDIX C BUFFER EXPANSION/EPROM UPGRADE C.1 M24SII-M01 BUFFER EXPANSION ZIP MODULE INSTALLAT ION Each one megaby te memory ex pansion upg rade kit pr ov ided by BayTech includes tw o memory ex pansion chips (D RAM IC s) w hich come in a zi g z ag i n-li ne package (Z IP).
5. Locate the diagonal notch on the DRAM IC. This notch must face the transformer when instal led in the appropr iate socket. WA RNING: If the DRAM ICs ar e installed i n backw ards, they wi ll be damaged and become inoper able. 6. Line up the pins of each DRAM IC w ith the 20 holes in the socket.
C.2 M24SII-M02 BUFFER EXPANSION SIMM INSTALLAT ION Each memory expansi on upgrade ki t prov ided by BayTech incl udes either a 1M B x 8 or 4MB x 8 SIMM (si ngl e in-l ine memory module). You may also use thir d party SIMMs . The total buffer size may rang e from 0MB to 16MB w ith a minimum of 1MB req uired for oper ation.
5. Hold the memor y ex pansion module in y our hand so that the card edge connector is facing dow n. IMPORTA NT: On the memory ex pansion module, Pi n 1 is mar ked. Pin 1 should be positi oned to the left of the unit (wi th LEDs facing you) . WA RNING: If module is plugged in backw ards, it will be damaged and become inoperabl e.
C.3 MODEL 24SII MAIN BOARD EPROM UPGRADE The materials you will receiv e w ith y our upgrade kit are: One EPROM (c hip w ith label ) The materials you will need to supply are: Phillips-head screwdriv er IC DIP ex tractor or a pair of curv ed needle- nose pliers 1.
C.4 MODEL 24SII MEMORY MODULE EPROM UPGRADE The materials you will receiv e w ith y our upgrade kit are: 1 EPROM (chip with label). This Chip w ill be marked to identif y w hich memory module ty pe they install into. The materials you will need to supply are: Phillips-head screwdriv er IC DIP ex tractor or a pair of curv ed needle- nose pliers 1.
C.5 MODEL 24SII I/O MODULE EPROM UPGRADE The materials you will receiv e w ith y our upgrade kit are: EPROM(s) (chip(s) with label). Chips w ill be m arked to identify which module ty pe they i nstall i nto. The upgr ade req uires one new EPROM per I/O module.
2. Remove the appr opriate I/O module by loosening the 2 straig ht- slot screw s that connect the back panel of the I/O module to the chassis and then pulling the module out. 3. If upgrading a serial module, locate socket U3 on the appr opriate I/O module (see Appendix D.
APPENDIX D MECHANICAL LAYOUTS D.1 MODEL 24SII FRONT PANEL.
D.2 MODEL 24SII UNIT ASSEMBLY.
D.3 MODEL 24SII MAIN BOARD.
D.4 M24SII-M01 MEMORY BOARD ASSEMBLY.
D.5 M24SII-M02 MEMORY BOARD ASSEMBLY.
D.6 I/O MODULE M24SII-V02: 4 PARALLEL PORTS.
D.7 I/O MODULES M24SII-V03/V06/V08: 4 HIGH SPEED SERIAL PORTS (MAIN BOARD).
D.8 I/O MODULE M24SII-V07: 4 HIGH SPEED SERIAL PORTS (CONNECTOR BOARD).
APPENDIX E TROUBLESHOOT ING Please check this troubleshooting guide before calling Bay Tech Tech Support. NOTE: This troubleshooti ng g uide is g eared tow ards the IBM PC , AT, XT family and compati bles.
PROBL EM SYMPTOM CAUSE SOL UTIO N Model 24SII DES po rt wh ich is confi gured as a printer port Port Des i gnat ion. LPTx not rerouted to COM x po rt fo r PC ser ial communicatio n Reroute COM port through DOS as follow s: MODE LPTx:=COMy (x=1, 2 or 3; y=1 or 2).
PROBL EM SYMPTOM CAUSE SOL UTIO N of the pri nt er HP LaserJ et gives " E rror 40" mes sage Serial pri nter cable or Model 24SII DES losin g power during transm is sion to pr inter The H P Lase rJet w ill give this messag e when its DSR l ine (Pin 6) goes from posit i ve t o negat ive or zero volts .
PROBL EM SYMPTOM CAUSE SOL UTIO N check pin 20 of peripheral t o pin 5 of Model 24SII DE S and/or pin 11 on parallel port s for cont inuity by us i ng an ohm m eter t o check resis t ance from end to end. Paralle l cable length Paral l el c able shoul d not exceed 15 f eet .
PROBL EM SYMPTOM CAUSE SOL UTIO N hangs up PC when executed PC rerouted for seri al communicatio n com mand: MODE LPTx:=COMy (x=1, 2 or 3; y=1 or 2). Floating condit i on on DSR or CTS lines ( i.e., cable problem ) Using TE RM program , chec k handshaki ng l i ne.
PROBL EM SYMPTOM CAUSE SOL UTIO N connect ion is made bet ween modem communicatio n soft ware and Model 24SII DES the com puter norm ally us es to pri nt with.
APPENDIX F INDEX 4-w ire 3, 4, 6- 8, 15, 16, 20, 35, 36, 38-45, 49, 80, 81, 112-116 8-w ire 3, 4, 6- 8, 15, 16, 20, 35-37, 49, 80, 81, 111 A Adapters 33, 35, 113, 115 Applicati ons 2, 3, 11, 34, 47, 4.
C Cabling 2, 4, 11, 14, 15, 25, 29, 30, 32, 33, 35, 37-40, 100, 107, 111, 112, 114, 116, 137 Case sensitiv e 69 CDT 98 Centronics 9, 25, 26, 106 Clear buffer command 54-56 Clear -to-Send 61, 63 CLR 54.
D Data Communicati on Equipment 27, 30, 33 Data flow contr ol 61, 139, 140 Data Terminal Equi pment 27, 30, 33 Data Terminal Ready 61 Data transfer 2 DB-25 8, 9, 14, 25-27, 30, 33, 35, 100, 104, 107, .
F Factory -default settings 15 FAX 98 Federal communicati ons commission 99 File transfer 57, 58 Floating condition 141 Flow control buffer 8, 9 Form feed mode 3, 6, 7, 15, 21, 69, 70, 72, 84, 87, 88 .
I I.D. page messag e 3, 6, 7, 15, 19, 22, 46, 50, 66, 69, 70, 72, 73, 84, 89-93 I.D. page pr inting schedule 66 I/O module 3, 15, 27, 30, 33, 35, 36, 43, 44, 107, 111, 117, 118, 127, 128, 134, 136 IBM.
M Main boar d eprom upg rade 125 Main board mechani cal lay out 125 Main configur ation menu 18, 69-71, 73- 78, 80, 84-96, 122, 124 Main config uration mode 79 Maintenance 97 Manual disconnect 21, 54,.
Parallel-to -serial 46 Parity 3, 6, 7, 11, 16, 17, 20, 24, 48, 49, 60, 67, 72, 80-83, 138, 139, 140 PC COM por t 17, 24, 137-140 PC Talk XVI 58 Peripher al-to- model 61, 63 Pin assig nment 26 Plotter .
Q,R Q-Modem 58 Queued 55, 56 Rack-mount 5 Radio and telev isi on reception 99 Radio freq uency 99 Ramexec 13, 23, 24, 47, 52, 59, 141 Readme 11, 13 Results codes 60 Return authori zati on 97 Ribbon ca.
T Technical Support 12, 97, 98, 137 Televi sion recepti on 99 Telex 98 Temperature 5 Term 17, 18, 67, 137-139, 141 Terminal 3, 15- 18, 27, 30, 33, 61, 67, 139, 140 Terminal emul ation prog ram 17, 18,.
X,Y,Z X- Modem 58 XMIT 20, 64, 72, 81- 83 XON/X OFF 3, 6-8, 11, 16, 20, 28, 31, 36, 38, 41, 49, 60, 62, 64, 67, 80-83, 116, 140 XON/X OFF handshaking 11, 36, 38, 41, 62, 64, 80.
OTHER BAYT ECH PRODUCT S Print Mast er 700 Series printer controller s are made in sev eral different configurations satisfyi ng v ari ous interface requi rements. Each unit allow s computers to share, select and/or contend for printers easily and economical ly , wi thout sw itching cables.
LaserShare is an in te lligent p rin te r contro lle r that a llo ws up to f o ur or eight computers to send data to a sing le HP LaserJet Series II, IID, III, IIID, Brother HL8e* and HL8v *, or W ang LDP8 laser printer . LaserShare connects directly into the optional I/O slot of the laser printer.
"500H" Series and t he Model 24SII DA C Data A cquisition and Control units connect betw een one host computer and multipl e peripheral devi ces.
Telplex Model TX108M is an asynchr onous statistical multiplex er w ith built-i n modem. Eig ht indiv idual communi cations channels are multiplex ed into a si ngle di al-up or l eased telephone li ne, cutting phone line costs to a mi nimum. The TX108M features a V.
Networking (F-Series): Netw orks either 5 or 9 ports tog ether, i.e., allow s any port to connect to any other port on the mul tiport contr oller . These also hav e host port control w hich allows a host computer system to make and/or break any connection betw een tw o ports on the multiport contr oller .
NOTES.
NOTES.
デバイスHP 24SIIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP 24SIIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP 24SIIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP 24SIIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP 24SIIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP 24SIIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP 24SIIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP 24SIIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP 24SIIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。