ページ先へ移動 of 12
Models LP350, LP400, LP450 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Contents: Installation Instructions: page 2 Pump Specifications: pages 3-5 Exploded View: page.
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 Specifications Model LP350 Volume ................................................................................................... Up to 22.6 GPM Discharge Pressure .................................................................................
4 Specifications Model LP400 Volume ................................................................................................... Up to 15.1 GPM Discharge Pressure .................................................................................
5 Specifications Model LP450 Volume ................................................................................................... Up to 19.7 GPM Discharge Pressure .................................................................................
6 LP350, LP400, LP450 - EXPLODED VIEW.
7 ITEM # PART # DESCRIPTION QTY 1 07759 Crankcase 1 2 13000 Oil filler plug assy. 1 4 06085 Crankcase Cover 1 5 07104 O-ring, Crankcase cover 1 6 07186 Oil Sightglass with Gasket 1 8 06086 Oil Dipstic.
8 PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace .
9 REPAIR INSTRUCTION - LP350, LP400, LP450 T O CHECK V AL VES 4) Inspect valve seats (46A) and valve plates (46B) for damage and replace if needed. Check valve casing (43) surfaces for damage. Replace o-rings (44A) and reinstall valve assemblies (46) into valve casing.
10 9) Remove seal case (37) from seal sleeve (35). 10) Check plunger surface (25 and 29B) for wear and pit- ting. If none is found, pro- ceed to step twelve. 11) If plunger (29B) is worn, re- move tension screw (29C) with a 17mm wrench. Clean tension screw with wire brush to remove any old locktite.
11 DISASSEMBLY OF CRANKCASE 1) Remove valve casing (43) and plunger pipe (29B), drain oil. 2) Screw off gear cover (4) and bearing cover (14). 3) Remove connecting rod screws (24) and push the front of connecting rod forward as far as possible. Remove back halves of connecting rods, note which position from which they came from.
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and car wash applications, the discharge manifolds will never fail, period.
デバイスHP Triplex Ceramic Plunger Pump LP350の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP Triplex Ceramic Plunger Pump LP350をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP Triplex Ceramic Plunger Pump LP350の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP Triplex Ceramic Plunger Pump LP350の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP Triplex Ceramic Plunger Pump LP350で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP Triplex Ceramic Plunger Pump LP350を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP Triplex Ceramic Plunger Pump LP350の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP Triplex Ceramic Plunger Pump LP350に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP Triplex Ceramic Plunger Pump LP350デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。